TCL Air Conditioner Service Manual
46
3.2 Trouble shooting
3.2.1 E0 ---IDU & ODU communication failure
Start
Display E0
IDU wiring
connection correct ?
Check communication
wiring and the connection,
in good condition?
ODU wiring
Connection correct?
Yes
Check and re-
connect
No
Main power supply
from IDU?
Yes
No
Replace/ re-
connect
Check and re-
connect
No
n
Check voltage from IDU
terminal btw L,N. is there
220V?
Replace IDU
PCB
No
Yes
Yes
Is the ODU PCB
LED5
ON
?
Replace ODU PCB
Check voltage from IDU
terminal btw L,N. is there
220V?
Check the power
supply connection
Replace or
reconnect
Yes
Is the ODU PCB
LED5
ON
?
Yes
Replace ODU PCB
No
No
No
End
ON
constantly
Flash
ON
constantly
Flash
No
Yes
Yes
E0 disappear?
Yes
No
E0 disappear?
No
Yes
E0 disappear?
No
No
Yes
E0 disappear?
Yes
No
Replace IDU
PCB
E0 disappear?
Yes
No
Содержание TCC-09C2HRH/DV