TCL TAC-09CHSA/GI Скачать руководство пользователя страница 4

4

Note: Each mode and relevant function will be further specified in following pages. 

SLEEP

FAN

TIMER

SWING

ON/OFF

MODE

MID

SWING

AUTO

DRY
FAN
HEAT

COOL

FEEL

SLEEP TIMER ON

HIGH

LOW

TMIER OFF

The remote controller transmits signals  to the system.

Remote controller

1

2

4

3

5

6

7

8

8

4

MODE  button

FAN SPEED control button

UP button (TOO COOL button)

DOWN button (TOO WARM button) 

ON/OFF button

SLEEP  button

VANE control button

 TIMER button

Used to select the type of operation mode:  Feel, 
Cooling, Dry, Fan and Heating(Only for Heat Pump).
 

Used to select the indoor fan motor speed:
 Auto, High, Mid and Low. 

Used to increase the set room temperature

 and time.

Used to decrease the set room temperature
and time. 

Used to set or cancel sleep mode operation. 

Used to start and stop operation 
when pressed.  

Used to adjust airflow direction.

Used to select TIMER operation.

Remote controller

6

2

5

3

7

1

1

1

TCL Air Conditioner Service Manual

Operation Details

Remote Control

The remote  controller is  not  preset

ted

  as Cooling  Only Air Conditioner  or Heat  Pump by  manufacturer.

Each time  after the  remote controller  replace batteries  or is  energized, the  arrowhead will  flashes on  the front  of 

Heat

or 

Cool

on LCD of the remote controller.

User can preset the remote controller type depending on the air conditioner type you have purchased as 
follows:
Press any button when the arrowhead flashes on the front of 

Cool 

, Cooling Only is set.

Press any button when the arrowhead flashes on the front of 

 Heat

, Heat Pump is set.

If you don

t press any button within 10 seconds, the remote controller is preset as Heat Pump automatically.

Note :

If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat Pump, it 
doesn

t bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you preset the 

remote controller  as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.

Содержание TAC-09CHSA/GI

Страница 1: ...PE AIR CONDITIONERS CONTENTS 1 IMPORTANT NOTICE 2 2 TECHNICAL SPECIFICATION 3 3 OPERATION DETAILS 4 4 WIRING DIAGRAM 11 5 EXPLOSION VIEW 12 6 PARTS LIST 13 Models TAC 09CHSA GI TAC 12CHSA GI TCL SERVI...

Страница 2: ...formation nor can it assume any liability in connection with its use The information specifications and parameter are subject to change due to technical modification or improvement without any prior n...

Страница 3: ...H x D Outdoor mm 760 560 260 760 560 260 Indoor kg 8 5 8 5 Outdoor kg 30 34 Packing dimensions Indoor mm 883 325 271 883 325 273 W x H x D Outdoor mm 863 598 381 863 598 383 Indoor kg 10 5 10 5 Outdoo...

Страница 4: ...ler 6 2 5 3 7 1 1 1 TCL Air Conditioner Service Manual Operation Details Remote Control The remote controller is not presetted as Cooling Only Air Conditioner or Heat Pump by manufacturer Each time af...

Страница 5: ...is overload controller shut down the unit immediately and show error code 6 Compressor abnormity protection When compressor start on or in the process of running if there is no feedback to controller...

Страница 6: ...or will run automatically 3 Auto fan control in cooling mode In cooling mode include cooling in I feel mode fan speed is determined by t as the following diagram 1 5 1 0 3 0 3 5 t come down high fan t...

Страница 7: ...ocess of defrosting 4 Defrosting Defrosting is controlled by the microprocessor When one of the following conditions is satisfied unit will come into defrosting a Outdoor heat exchanger Temperature OP...

Страница 8: ...later z When selecting HEATING operation with SLEEP mode the set temperature will be dropped by 1 1 hour later and 2 2hour later z After the System operates in SLEEP mode for 8 hours it will stop auto...

Страница 9: ...of the error list z Protection display function can be selected in hardware and the default don t display z To insure of in and out communist is credibility the failures relate to outdoor unit will r...

Страница 10: ...tdoor power board when compressor is running it is normally light when no feedback of signal to power board from compressor it will wink by lighting 1s and going out 1s If failures happened it will li...

Страница 11: ...TCL Air Conditioner Service Manual Wiring diagram Model TAC 09CHSA GI TAC 12CHSA GI Indoor unit Outdoor Unit 11...

Страница 12: ...TCL Air Conditioner Service Manual EXPLOSION VIEW Indoor unit Model TAC 09CHSA GI TAC 12CHSA GI 12...

Страница 13: ...filter 2 13 1070321113 panel 1 14 1070321107 Ornament strip 1 15 1170120045 Power supply cord 1 16 1070320104 vane 1 17 1070110008 Drainage hose 1 18 1070040004 Cable clamp 1 19 1170200042 Terminal 1...

Страница 14: ...r filter 2 13 1070321113 panel 1 14 1070321107 Ornament strip 1 15 1170120045 Power supply cord 1 16 1070320104 vane 1 17 1070110008 Drainage hose 1 18 1070040004 Cable clamp 1 19 1170200042 Terminal...

Страница 15: ...TCL Air Conditioner Service Manual EXPLOSION VIEW Outdoor unit Model TAC 09CHSA GI TAC 12CHSA GI 15...

Страница 16: ...necting pipe 1 15 1120250425 Suction pipe 1 16 1120250426 Discharge pipe 1 17 1120250428 Condenser connecting pipe 1 18 1120250615 Capillary assembly 1 19 1140020011 Sound arrester 1 750 350 8 20 1080...

Страница 17: ...nual 17 PART LIST Outdoor unit Model TAC 09CHSA GI No Part No Part Name Q ty Remark 38 1190070020 Base carton 1 39 1190700302 Cabinet carton 1 40 1190070022 Base foaming 1 41 1190070021 Cover foaming...

Страница 18: ...pipe 1 15 1120321529 Suction pipe 1 16 1120321530 Discharge pipe 1 17 1120321532 Condenser connecting pipe 1 18 1120321525 Capillary assembly 1 19 1140020011 Sound arrester 750 350 8 1 20 1080050002 R...

Страница 19: ...nual 19 PART LIST Outdoor unit Model TAC 12CHSA GI No Part No Part Name Q ty Remark 38 1190070020 Base carton 1 39 1190700302 Cabinet carton 1 40 1190070022 Base foaming 1 41 1190070021 Cover foaming...

Отзывы: