Factory Test & Alignment Specification For MS08PA-LA Series (V1.0).Doc
Page 12 of 18
The second method
:
To use this method, there should be SW in mainboard to ensure TV can display normally.
Copy the SW BIN image
“V8-6328L14-LF1VXXX.bin”
into USB stick (pen drive) root path
Press RCU
MENU
Setting
Function
software upgrade
OK
By USB
TV display warning information, that means it is upgrading, almost 3minutes later, when
upgrade successful, TV should restart automatically.
Appendix
“How to change ProjectID with RCU
”
Process following subsequence IR codes to change project ID:
MENU+xxx
(xxx:
Project ID, ex: 001)
Restart TV
Appendix
“
How to upgrade MAC Address
Upgrading MAC address need to use the tool in factory and through serial command, the
specific methods according to the operation of the factory guidance.
Appendix
“
Factory Menu Description
”
1- Factory hotkey
submenu
Item
Sub-item
Value
Note
Factory
hotkey
Off/On
OFF
:
hotkey is invalid
ON
:
hotkey(Return key) is availability
2-Warm-Up Mode
submenu
Item
Sub-item
Value
Note
Warm-UP
Mode
Off/On
Select panel On with left/right key, Press
“EXIT” key to enter the burning mode;
Press “Menu” key on keyboard to exit the
burning mode
3-ADC
submenu
As SoC as built-in A/D self-calibration mechanism, there’s not any ADC to perform.
4-White Balance
submenu
Item
Sub-item
Value
Note
White
Balance
Source
HDMI,etc
Balance source are
:
HDMI, ATV, DTV, PAL, NTSC, CMP
Color Temp
Normal
/Warm/Cool
Warm and cool value is relative to Normal
one. Normal is the default Tone mode
R Gain
000..255
R White balance (-127..+128 for gain)
G Gain
000..255
G White balance (-127..+128 for gain)