13

RECALL  - 

FRONT PANEL OPERATION

Presets

The Reverb 4000 holds 150 factory presets.
These are arranged in various categories such
as Halls, Rooms etc - see below.

To make a simple Recall

• Press Recall to ensure you are at the Recall

Page.

• Select the preset you wish to recall using the

CONTROL wheel.

• Press ENTER.

The Reverb 4000 also has various filter
functions to ensure fast and efficient preset
search.

Category Filter

Make your primary selection based on Category.

• Use the ARROW UP/DOWN keys in the

Control section to scroll between different
categories.

The options are:

• Use the ADJUST wheel to select a specific

preset within the selected Category.

• Press ENTER to recall the selected preset.

Recall Wizard

When “Wizard“ is selected it is only possible to
select between the presets matching the criteria
set in the Wizard menu. (See next page for
explanation).

Preset Number

Preset Name

Application

Parameters &
current values

Category Filter

Function

Upper Section

Lower Section

To access the Recall display simply press RECALL.

To make an appropriate preset selection fast and efficiently we have added both a Category Filter
for rough selection but also a Recall Wizard functionality that will help you narrow down and pick
the appropriate preset for you application.

Содержание REVERB 4000

Страница 1: ...REVERB 4000 HIGH DEFINITION REVERB U Us se er r s s m ma an nu ua al l...

Страница 2: ......

Страница 3: ...uipment should be installed near the socket outlet and disconnection of the device should be easily accessible To completely disconnect from AC mains disconnect the power supply cord from the AC recep...

Страница 4: ...Digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generates uses...

Страница 5: ...C ICON Installation 21 The TC Icon Editor Quick Start 23 Basic Operation Setup Select pages 24 Operating Pages 24 Preset Structure Recall Store Delete 26 Bank Handling 26 Preset Handling 27 System I O...

Страница 6: ......

Страница 7: ...azing palette of simulated rooms from natural sounding credible spaces to emulations of vintage reverbs and TC Classics On top of offering front edge pristine reverb technology it features impressive...

Страница 8: ...urrent Input level DISPLAY The display is divided into two sections The Upper section is dedicated to essential information operation such as Recall Store and Wizard functions plus I O and Utility The...

Страница 9: ...in a user location User location can be selected using either the CURSOR UP DOWN keys or the CONTROL ADJUST wheel Press ENTER to confirm and execute WIZARD key Press to enter the Wizard recall mode V...

Страница 10: ...utput Balanced Analog Outputs XLR S PDIF Input Output Power Input 100 240V Power Switch XLR to XLR XLR to Jack Stereo XLR to Jack Mono USB MIDI In Out Thru Optical ADAT S PDIF Cables wiring Note The U...

Страница 11: ...SIGNAL FLOW 9...

Страница 12: ...tereo signal from e g a mixer AUX section Via the Input Ch parameter found in the I O menu it is possible to chose which Input channel to be processed Select between Left Right and Stereo Input Connec...

Страница 13: ...connection ensures communication with the TC Icon Software Editor Open the TC Icon Editor and select appropriate port on the Setup Devices Port page Connect MIDI In Out if needed Connect digital audi...

Страница 14: ...s instantly be adjusted using the F1 F2 and F3 VALUE wheels Category Filter Function Preset Number Upper Section Lower Section Controls for any action concerning the upper section of the display HOME...

Страница 15: ...different categories The options are Use the ADJUST wheel to select a specific preset within the selected Category Press ENTER to recall the selected preset Recall Wizard When Wizard is selected it i...

Страница 16: ...Size Defining the size of a specific Reverb type is a delicate issue Altering Decay times considerably on a defined room size is not equivalent to changing the size of the room We suggest selecting S...

Страница 17: ...up function Locat Location Select a user location where you wish to store the preset The Reverb 4000 itself has 100 user locations With a standard PCMCIA card an additional 100 presets can be stored I...

Страница 18: ...hapter all parameters controllable via MIDI CC are marked with corresponding MIDI CC numbers A complete list is also available in the appendix section Following CC modes are available Off No response...

Страница 19: ...SysEx Range On Off Determines whether the Reverb 4000 should respond to incoming MIDI Sysex MIDI Out Program Change Range On Off Program changes are sent to MIDI Out when presets are recalled via fro...

Страница 20: ...y incoming program changes to recall any preset in the Factory User or Card bank Mapping Normal In Normal mode all banks can be accessed for program changes Bank selection is done via Ctrl 0 MSB and C...

Страница 21: ...e be set to that value Clock Clock Mode Clock Select Clock mode can be set to Normal or Double Normal If Clock Mode is set to Normal the following options are available 44 1 48 Di In Wordclock Double...

Страница 22: ...nput Input Select Range AES EBU ADAT Optical Selects digital Input type Digital Input must be selected Digital Input Trim Range 24 dB to 0 dB Step 0 2 dB Trim parameter on the digital Input Signal is...

Страница 23: ...ware Editor that currently controls the following products by TC Electronic System 6000 DB 8 P2 and Reverb 4000 In this section only subjects relevant for usage with the Reverb 4000 will be discussed...

Страница 24: ...N SOFTWARE EDITOR Now specify at which location the Wizard should look for the appropriate driver The Wizard now finds the correct driver on the CD ROM Press NEXT Press Finish The Driver is now instal...

Страница 25: ...nation on the previous page of this manual Power up the Reverb 4000 and start the TC Icon software on your computer Go to the Setup Devices Select page Press the DETECT key The TC Icon Editor will sca...

Страница 26: ...rating Pages Library pages handle operations such as preset Recall Store Delete and bank handling for backup System pages handle overall Clock Settings I O settings and network settings Engine pages a...

Страница 27: ...ls Rooms etc Then select the desired preset by touching the preset name in the list Then press RECALL Info Info Presets marked with the small Info tag have additional description attached Press the In...

Страница 28: ...ord Hall and meet the criteria defined by the Source Size and Origin settings are now available for recall Reset Resets all Search settings 26 Store Delete To store a preset Select the Store page by p...

Страница 29: ...computer this is where these files will appear To Bank Select to which Reverb 4000 bank you wish to copy the selected bank to To File Select To File if you wish to back up the selected bank to your ha...

Страница 30: ...Rate Digital In Word Clock Locked Clock Indicates whether the Reverb 4000 is locked to the clock present on Digital Inputs Digital Output Dither Range 8 12 14 16 18 20 22 24 off Reverb 4000 processes...

Страница 31: ...the Max I O level must be correctly set to match the device to which the Reverb 4000 is connected Example If the Mixers Max I O level is 18dBu the Max I O Level parameter should be set to that value...

Страница 32: ...esets from the User bank Card Bank Incoming Program Changes are mapped to recall presets from the Card bank This requires that a Reverb 4000 formatted PCMCIA card is inserted in the Card slot Custom M...

Страница 33: ...map to Fill From Current This is a convenient function you may choose to use when creating a map to list Example 001 mapped to 001 002 mapped to 002 003 mapped to 003 025 mapped to 201 Press Fill Fro...

Страница 34: ...rd It is also possible to dump a binary file to a PCMCIA card inserted in the Reverb 4000 This function is especially useful when updating software Be aware that Dumping a Binary File to a PCMCIA card...

Страница 35: ...t side No faders No faders visual on the screen Trim Press the value field to activate the Trim function With the Trim function a higher value resolution is available on most parameters for fine adjus...

Страница 36: ...ce for composite mixed material and stems 1st choice when used with multichannel joystick on console or DAW 1st choice for adding to classical main microphone pick up Works well on moving sources Pret...

Страница 37: ...kers due to compromises by nature built into the emission and pick up process when capturing a room response This is especially true with multichannel formats such as 5 1 and 6 1 where DSP in simulato...

Страница 38: ...Early Reflections HiCut Range 20Hz to 20kHz Determines the Hi Cut frequency for the Diffuse Field part of the Reverb Reverb Size Range 0 to 15 Adjusts the overall perceived size of the Diffuse Field p...

Страница 39: ...0 to 100 Adjusting the Start time is an efficient way of getting rid of the first reflections that normally color the source the most By adjusting the Start time the first reflections are discarded b...

Страница 40: ...ng together to remove the frequencies that give a brittle or harsh sounding Reverb Hi Soften is scaled linked to the Hi Cut and Hi Decay parameters Hi Cut Range 20 to 20kHz Attenuates the high end fre...

Страница 41: ...erent types of modulation on the five Reverb diffuse fields Modulation Rate Range 50 Adjusts the Rate of the selected modulation Modulation Depth Range 0 200 Adjusts the Depth of the selected modulati...

Страница 42: ...p end of the signal as it enters the Reverb Used in conjunction with Hi Soften and Hi Decay to darken a room Pre Delay Range 0 to 100ms A Delay placed at the Input of the algorithm This sets how long...

Страница 43: ...he left right balance of the Early Reflections Allows you to offset the Early Reflections from the normal center position Reverb page Reverb Reverb Type Range Smooth Natural Alive Fast Fast Wd Alive W...

Страница 44: ...control multiplier for the low mid frequencies HiMid Decay Range 0 01 2 5 The Ratio control multiplier for the mid frequencies This parameter is normally set to 1 0 as it is the main parameter adjuste...

Страница 45: ...Space Mod Depth Range 50 default 50 Allow you to offset the amount of space modulation from the factory default In the Reverb 4000 user interface the parameters of this algorithm are organized as foll...

Страница 46: ...lays in the 10 40 ms range can be considered for percussive sounds while dense vocal slap effects could use 70 150 ms of Pre Delay Attack Range 0 500ms Sets the Attack time build up of the Reverb Enve...

Страница 47: ...eters gets out of control the Lo and Hi cuts can be used to stay within limits When the Twist Ratio is set at 0 Twist Type has no effect Ratio Range 0 100 Applies the selected amount of Twist to the R...

Страница 48: ...aking sure the qualities of the original processor was preserved Sweet modulation spectral characteristics spaciousness distortion saturation etc Hundreds of hours spent listening and measuring User T...

Страница 49: ...end the overall frequency spectrum Hi Q Scale Corresponds the small potmeters inside older reverbs used to equalize sound differences caused by electric component tolerances Use the Q scale in combina...

Страница 50: ...ary to attenuate the input to avoid overload Dry Level Range Off to 0dB Dry Level control In send return configurations the parameter should be set to Off Rev1 Rev2 page Reverb Decay Master Decay para...

Страница 51: ...er related to Master Decay for frequencies above the Mid Xover setting Lo Xover Sets the Cross over frequency between the Lo and LoMid Decay Mid Xover Sets the Cross over frequency between the LoMid a...

Страница 52: ...Mid Studio Small Corridor Small Studio Medium Room Corner Close and Corner Far Simply defines the basis location type emulated Position Range 100 Left to 100 Right 0 is Center Position panner for the...

Страница 53: ...the Room Decrease to set focus on the Diffuse part of the algorithm Reverb Level Range 100dB to 0dB The Output level of the diffuse field part of the algorithm When Rev Level is set to off the effect...

Страница 54: ...t assigned to each Type Depth Range 25 to 25 Allows you to offset the amount of space modulation from the factory default REVERB 4 In the Reverb 4000 user interface the parameters of this algorithm ar...

Страница 55: ...mber X X True Voice X X Velocity Note ON X X Note OFF X X After Touch Key s X X Channel X X Pitch Bend X X Control Change O O Prog Change O O SysEx O O Common Song Pos X X Song Sel X X Tune System rea...

Страница 56: ...kHz 48 kHz 88 2 kHz 96 kHz 0 2 ms 48 kHz DC to 23 9 kHz 0 01 dB 48 kHz DC to 47 9 kHz 0 01 dB 96 kHz XLR balanced pin 2 hot 20 Kohm 22 dBu balanced 10 dBu 12 dB headroom 22 dBu to 10 dBu 24 bit 6 144...

Страница 57: ...nty Parts and labor 32 F to 122 F 0 C to 50 C 22 F to 167 F 30 C to 70 C Max 90 non condensing PC Card 68 pin type 1 cards PCMCIA 2 0 JEIDA 4 0 Supports up to 2 MB SRAM In Out Thru 5 Pin DIN Anodized...

Страница 58: ...Theatre Church Vocal Hall 1 Vocal Deep Boston Garden Hall Amsterdam Hall Showtime Cool Pop Ballad Live Pop Ballad GM Hall M5 Church1 M5 Church2 M5 480 Hall M5 SlapHall M5 WoodHall M5 5000Hall M5 Live...

Страница 59: ...t Rap Club Overhead Mics In The Room Tight Natural Store Room Furnished Room 2 A Small Room Stretched Room Slaugterhouse Medium Basement Box 40x40 ft Subtle Studio Box Car Subtle Room Small Corridor S...

Страница 60: ...ate Dual Plate 2 Rooms 2 Halls 4 You Dual Backyard Super Strings Nice Vocal Ballad Vocal Church String Hall Nice 4 Perc Scoring Stage Snare Plate DVR 2 DVR 2 Rev 4 VSS3 VSS3 Rev4 DVR2 VSS3 DVR2 Rev4 D...

Страница 61: ...oinkygate Thick Slapback Tight Stereo Slap Dense Dark Room Dense Arena NonLin Slap Ricochet Verb Tight Smooth 80 s 808 Studio Spring Nonlin Vocal RichVerb M5 NONLIN 2 NONLIN 2 NONLIN 2 Rev 4 NONLIN 2...

Отзывы: