MAIN FRAME - FRONT & REAR PANEL
POWER ON
MAINFRAME/SYSTEM 6000
FLOPPY DRIVE
POWER
PC CARD
System 6000 Mainframe Front
Power Key
Switches power On/Off.
3.5” floppy disc slot
For storing presets and event-lists and for loading software-
upgrades.
System 6000 Mainframe Rear
I/O Slot A
I/O Slot B/AES-8
DSP Slot
I/O Slot C
DSP and I/O Slots A, B and C
These slots are used for I/O cards ADA 24/96 and AES-8.
Slots must be filled consecutively in alphabetic order.
The System 6000 DSP card fits the DSP slot only. When
I/O cards are mounted, dip switches on the cards must be
set accordingly.
An AES-8 card should be installed in “I/O Slot B/AES-8”
only. If you Mainframe rear panel carries a label saying
BUS updated you can install the AES-8 card yourself -
Please refer to the full manual.
If your Mainframe serial number is below 285580 and no
“BUS-updated label” is present on the rear-panel, a
Mainframe hardware update performed by an authorized
TC Service center is necessary before installation.
For further information contact:
TC Headquarters : [email protected]
+45 87427000
US Customer
001 805 373 1828
Power In
100-230V AC. 50/60Hz - auto-select.
SMPTE
1/4” connection for SMPTE sync. Input.
Ethernet/LAN
Connection for external control devices e.g. the TC Icon.
The type is 32 bit PCI Ethernet interface fully compliant
with IEE 802.3u 10/100 Mbps CSMA/CD standards.
The connector type is a 100Base-T RJ-45 (CN13)
Ground Lift
Use this standard chassis ground lift if you encounter
problems with hum.
MIDI In, Thru and Out
5 pin DIN connectors.
Remote
This connection is for service and test purposes only.
GPI
General Purpose Input. Connect a TC Master Fader or a
tip-to-ground switch. Applications vary depending on the
specific algorithm.
Rackmounting Advice
• The Mainframe 6000 should not be placed in an
environment with a temperature exceeding 50 degrees
celsius.
• Do not cover the ventilation openings on the sides of the
frame.
The cooling fan is activated according to the
temperature inside.
PCMCIA slot
For future software facilities and handling of additional
preset banks.
Power On LED
During start-up this LED is red. When the unit is ready for
use, the LED will turn green.
BUS updated - label
26
Содержание Mastering 6000