CLONING DB2’S

Cloning DB2s 

Cloning DB2’s using a PCMCIA card

Once a single DB2 has been set up for the 

desired applications, other DB2’s in the house 

can be easily cloned using a standard PCMCIA 

card. In other words; it is NOT necessary to 

hook up every single DB2 to a computer to set 

these up.  

•  Insert an unprotected PCMCIA card into the 

source DB2’s card slot. 

•  Go to the TC Icon System/Card page. 

•  Decide whether you wish to exclude the 

System Preset that hold overall Clock 

settings, Analog Trim levels, Dither, Status 

Bit settings and GPI settings. To exclude the 

System Preset, activate the “Exclude System 

Preset” button. 

  Then click CREATE CLONE CARD. 

 ALL DATA previously stored on the card 

will be destroyed when formatting the 

card! If the card is write-protected, no 

data can be written on the card. The 

protect/unprotect switch is located at the 

edge of the card.

•  Remove the card and go to the target DB2 

unit. 

•  Power off the target DB2 unit. 

•  Insert the card and power up using the front 

panel POWER key while holding the OK key 

pressed. Press UTILITY until the display 

shows “C” (CLONE). 

•  Now press the OK key. All settings (with or 

without “System Preset”, depending on your 

previous selection) are now copied to the 

target DB2. 

SYSTEM – I/O PAGE

Parameters on the System page can be 

stored and recalled via System presets and 
are unaffected by normal Recall operations.

Clock Preferences

Analog

Range:  Internal 44.1 kHz

   

Internal 48 kHz

   

Ext. W. Clk. (External Word Clock)

   

Ext. DI

Sets the processing clock frequency to be used 

when analog inputs are used.

Digital

Range:  Internal 44.1 kHz

   

Internal 48 kHz

   

Ext W Clk (External Word Clock)

   

Ext. DI

Sets processing clock frequency to be used 

when processing signal from the AES or S/

PDIF input.

Digital w. SRC

Range:   Internal 44.1 kHz

   

Internal 48 kHz

   

Ext Word Clock

Sets the processing clock frequency to be used 

when Digital SRC is selected on the Engine I/O 

page.

Analog Trim

Input Trim L & Input Trim R

Range: +1.00 to -1.00 dB in 0.05 dB increments

Level trim for analog inputs.

Output Trim L & Output Trim R

Range: +1.00 to -1.00 dB in 0.05 dB increments

Level trim for analog outputs.

Digital Output

Dither

Range: 8, 12, 14, 16, 18, 20, 22, 24, off

DB2 processes audio signals internally at 48 bit 

resolution. Dither must be set to match down-

stream devices.

Status Bits

Select whether the DB2 should send out AES/

EBU or S/PDIF status bit information.

GPI 

The GPI input reads the analog DC level fed 

to this port, and may be assigned to a variety 

of functions: It may set the output level, add 

or change the on-line delay, enter and exit 

bypass, and make DB2 switch between up to 8 

presets.

GPI Assign

Disabled

The device connected to the GPI port is disre-

garded.

Fader

Select this setting to enable GPI control of 

DB2’s output gain. The DC level on the tip of 

the connector is read and used to adjust the 

output gain (“Output Fader” on the Engine/

Limit page). Inside DB2, a 10 kOhm resistor 

is connected b5 V and the tip of the 

GPI jack. Therefore, a passive external fader or 

potentiometer can be used to control the output 

gain. Use the Calibration function to optimize 

the control range for a given pot.

Bypass

Select this setting to enable bypassing DB2 

using an external switch. Note that you may 

accidentally put DB2 to bypass mode when 

selecting between the GPI settings. The Bypass 

function is defined on the System/Front page.

Bypass and Redundancy

DB2 includes hardware bypass on its analog as 

well as AES3-id inputs and outputs.

When selected, the unit furthermore constantly 

monitors its digital inputs for signal integrity. 

If the digital input is lost, automatic input 

redundancy switching is invoked. In this case, 

DB2 switches to internal 48 kHz sample rate 

operation and analog inputs.

Redundancy alarm is indicated by the 48 kHz 

and Analog In LEDs blinking and the ERROR 

LED lit. Once the digital input is reestablished, 

DB2 reverts to normal operation and clears the 

alarm.

Содержание DB2

Страница 1: ...DB2 LOUDNESS CONSISTENCY PROCESSOR USER S MANUAL...

Страница 2: ...as been dropped This equipment should be installed near the socket outlet and disconnection of the device should be easily accessible To completely disconnect from AC mains disconnect the power supply...

Страница 3: ...ent lighting control apparatus for professional use Part 1 Emission EN 55103 2 Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Pa...

Страница 4: ...Step by Step With the launch of DB2 TC Electronic also introduces a new commitment to buyers of any DB processor Within two years of the original purchase users may upgrade DB2 to DB4 or DB8 and DB4 t...

Страница 5: ...e DB2 s card slot Go to the TC Icon System Card page Decide whether you wish to exclude the System Preset that hold overall Clock settings Analog Trim levels Dither Status Bit settings and GPI setting...

Страница 6: ...rently recalled preset has been edited but not stored GAIN Meter Indicates the current Loudness correction gain as per ITU R BS 1770 or ITU R BS 1770 2 OPTIMIZE Meters Indicates gain reduction in the...

Страница 7: ...2 9 pin Sub D BNC Sync In GPI IN RS232 For connecting to a PC RS232 port use a standard 9 pin Sub D cable Supplied For connecting to a PC USB port use the supplied RS232 to USB connector Note max reco...

Страница 8: ...tart the installation of the TC Icon Software Editor will proceed Follow the instructions A TC Icon shortcut will appear both on the desktop and in the Start menu The MS installer is a small installat...

Страница 9: ...nly subjects relevant for usage with the DB2 will be discussed DB2 is connected to your computer via a serial COM port RS232 or via the supplied RS232 to USB converter Please note that RS232 can be us...

Страница 10: ...page User Presets The User banks U1 to U8 can hold up to eight presets each Factory Presets DB2 comes loaded from the factory with a collection of general purpose factory presets organized in banks F...

Страница 11: ...ital SRC is selected on the Engine I O page Analog Trim Input Trim L Input Trim R Range 1 00 to 1 00 dB in 0 05 dB increments Level trim for analog inputs Output Trim L Output Trim R Range 1 00 to 1 0...

Страница 12: ...as a fraction of Vs and as a guideline typical voltages when Vs 5 000 V If the supply voltage is e g 5 015 V the table should be corrected by multiplying these values by 5 015 5 GPI Implementation Thr...

Страница 13: ...or the two yellow digits on the In Out meters SYSTEM NET PAGE ICON VIEWS The upper part of this page holds information on the current software versions and the serial number of the accessed unit Netwo...

Страница 14: ...the set Analog Scale Output level MAIN PAGE Input In Gain Range 0 dB to Off There are separate level controls for the left and right Input A and B Phase Inv L R Range Normal Inverted Click to invert t...

Страница 15: ...l is relative to Reference Level on the Main Page Add Target Level to Reference Level to calculate the target loudness level When Loudness Measure is set to BS 1770 2 the calculation will have the uni...

Страница 16: ...s adjustments EQ PAGE Introduction DB2 features a digital three band parametric EQ with high pass and low pass filters switch able between Notch Parametric Shelving and Cut types The needle sharp notc...

Страница 17: ...Mid Gain 12 dB to 12 dB Hi Gain 12 dB to 12 dB Range for the Notch filter Lo Gain 100 dB to 0 dB Mid Gain 100 dB to 0 dB Hi Gain 100 dB to 0 dB EQ PAGE Type Click TYPE and use Faders 1 to 3 to set the...

Страница 18: ...pplied from the multiband system Below the Defeat Threshold the frequency response is flat and gain is unity Defeat Threshold is relative to Compressor Threshold which is relative to Reference Level D...

Страница 19: ...h between emphasis Off HD and normal DTV broadcast 50 microsec 75 microsec and J17 NICAM emphasis Note When pro nounced Emphasis Limiting is required it is normally advisable to link the limiters to a...

Страница 20: ...r BNC AES3 id 75 ohm RCA Phono S PDIF AES3 id 24 bit S PDIF 24 bit EIAJ CP 340 IEC 958 HPF TPDF dither 8 to 24 bit BNC 75 ohm 0 6 to 10 Vpp 32 kHz 44 1 kHz 48 kHz 0 5 ms 48 kHz 0 to 1000 ms 24 bit at...

Страница 21: ...higher For AC3 transmission however the Limit Threshold should not go much above 6 dBFS to avoid distortion in consumer devices If DB2 is processing for a low dynamic range platform such as IPTV or Mo...

Страница 22: ...cable The Input meters will show 0 dB The symbol will indicate that the test is positive The symbol will indicate that there is a problem with the input or the output Test 4 RS232 remote I O Test Con...

Страница 23: ......

Отзывы: