background image

IMPORTANT SAFETY INSTRUCTIONS

1

Read these instructions.

Keep these instructions.

Heed all warnings.

Follow all instructions.

Do not use this apparatus near water.

Clean only with dry cloth.

Do not block any ventilation openings. Install
in accordance with the manufacturer's
instructions.

Do not install near any heat sources such as
radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce
heat.

Do not defeat the safety purpose of the
polarized or grounding-type plug. A polarized
plug has two blades with one wider than the
other. A grounding type plug has two blades
and a third grounding prong. The wide blade
or the third prong are provided for your safety.
If the provided plug does not fit into your
outlet, consult an electrician for replacement
of the obsolete outlet.

10  Protect the power cord from being walked on

or pinched particularly at plugs, convenience
receptacles, and the point where they exit
from the apparatus.

11  Only use attachments/accessories specified

by the manufacturer.

12 

Use only with the cart, stand, tripod,
bracket, or table specified by the
manufacturer, or sold with the
apparatus. When a cart is used, use
caution when moving the
cart/apparatus combination to avoid

injury from tip-over.

13  Unplug this apparatus during lightning storms

or when unused for long periods of time. 

14 Refer all servicing to qualified service

personnel. Servicing is required when the
apparatus has been damaged in any way, 
such as power-supply cord or plug is
damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does
not operate normally, or has been dropped.

This equipment should be installed near the 
socket outlet and disconnection of the  device 

should be easily accessible.

Do not install in a confined space.

Do not open the unit - risk of electric shock 
inside.

Caution:

You are cautioned that any change or
modifications not expressly approved in this
manual could void your authority to operate this
equipment.

Service

There are no user-serviceable parts inside. 

All service must be performed by qualified 
personnel.

Warning!

To reduce the risk of fire or electrical shock, do
not expose this equipment to dripping or
splashing and ensure that no objects filled with
liquids, such as vases, are placed on the
equipment.

This apparatus must be earthed.

Use a three wire grounding type line cord like
the one supplied with the product.

Be advised that different operating voltages
require the use of different types of line cord
and attachment plugs.

Check the voltage in your area and use the
correct type. See table below:

Voltage 

Line plug according to standard

110-125V

UL817 and CSA C22.2 no 42.

220-230V

CEE 7 page VII, SR section 
107-2-D1/IEC 83 page C4.

240V

BS 1363 of 1984. 
Specification for 13A fused 
plugs and switched and 
unswitched socket outlets.

The lightning flash with an arrowhead
symbol within an equilateral triangle is
intended to alert the user to the 
presence of uninsulated "dangerous volt-

age" within the product's enclosure that may be of
sufficient magnitude to constitute a risk of 
electric shock to persons.

The exclamation point within an
equilateral triangle is intended to alert
the user to the presence of important
operating and maintenance (servicing)

instructions in the literature accompanying the
product.

a

Содержание C400XL

Страница 1: ...C400XL DUAL STEREO GATE COMPRESSOR U US SE ER R S S M MA AN NU UA AL L...

Страница 2: ......

Страница 3: ...tus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped This equipment should be installed near the socket outlet and disconnection of the device should be...

Страница 4: ...a Class B Digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment genera...

Страница 5: ...iagram 9 Typical setups 10 Cables important 12 BASIC OPERATION Preset applications 14 C400XL Processing Compression basics 16 Comp Limiter mode C400XL 17 Gate Expander mode C400XL 18 New Style Compres...

Страница 6: ...o stereo MONO OR STEREO OUT 2 OUT 1 IN 1 IN 2 dual mono mode engine 1 engine 2 choose if you wish to process a signal with both processing engines Note that this routing works for both a stereo setup...

Страница 7: ...ression or a combination and C400XL is up for the task at hand And finally there is the intuitive fast use of C400XL source based compression intuitive user interface and a mix knob for parallel compr...

Страница 8: ...ollowing descriptions of controls are valid for both Engines 1 and 2 PRESET selector Use the PRESET selector to select the desired source preset for Engine 1 METERS I P dB Input meter showing the sign...

Страница 9: ...hold ratio makeup mix release amount engine 2 metering program male vocal vocal choir speech bass guitar elec guitar acoustic guitar 6 3 12 6 18 12 24 18 48 24 3 1 i p dBfs damp 5 5 15 15 algorithm GA...

Страница 10: ...40 VAC switchmode power supply The C400XL accepts any voltage from 100 to 240 VAC UL60065 EN IEC 60065 CSA file no LR 108093 PROFESSIONAL AUDIO EQUIPMENT SERIAL NO TYPE PC002 TC ELECTRONIC MADE IN THA...

Страница 11: ...AL IN GAIN MIX ANALOG OUTPUTS pseudo balanced Left Left Right Right Digital Output S PDIF Digital Input S PDIF D A Input PPM A D AUTO SENSE ANALOG DIGITAL AUTO DETECT Fullband Expander Limiter Multiba...

Страница 12: ...0 5 5 dB dB sec sec ratio ratio dB dB thresh thresh overload overload digital in dual mono power stereo serial 20 20 40 40 50 50 10 10 2 2 3 3 5 5 8 8 threshold threshold ratio ratio makeup makeup mix...

Страница 13: ...IMITER PAR EQ PAR EQ DIGITAL IN OUTPUT A B RECALL ENTER LOCK STORE EDIT SETUP CLIP 0 dB A B 5 10 15 20 30 40 CONTROL SCHEMATIC Studio B Surround LS RS OUT 1 IN A IN B OUT 2 OUT 3 OUT 4 Amp Amp C400XL...

Страница 14: ...ing consoles do not feature balanced insert points and thereby downgrade these signals compared to the balanced main inputs The result is potential hum and noise induced when using standard insert cab...

Страница 15: ...rd XLR to TRS type 3a If this is the case it is most likely because the ring connection is floating unconnected inside the device you are connecting to In that case use an XLR to TS cable type 3b wher...

Страница 16: ...ers have the Voc Choir preset will do the job Use the compressor to control the gain of your source or use the expander to lower the noise floor Applied algorithm in Comp Lim mode Multi band Compressi...

Страница 17: ...Exp Gate mode Wideband Expansion Percussive A full set of percussion instruments has a huge dynamic range that is very difficult to control With the Percussive preset you can avoid any surprises that...

Страница 18: ...pes of devices In quite moments when the hum becomes a problem the hum can in a smooth and easy way be eliminated by using the De Hum preset simply by adjusting the parameters The preset can only be u...

Страница 19: ...w the Ratio is the steepness of the curve after the compressor threshold The Attack time is the time it takes for the compressor to reach the compression amount specified by the set ratio The Release...

Страница 20: ...revents close to all overshoots For different purposes there are different Limiter types The C400XL limiter is a peak type limiter and it is automatically active on all preset types using the multi ba...

Страница 21: ...the same time you want to enhance the singer s breath and the low end frequencies to make it more present and sounding as if the singer is just a few inches away You still want to maintain the signal...

Страница 22: ...Update Updating the C400XL software is easy Download the software application from www tcelectronic com Connect the computers MIDI out to C400XL MIDI in C400XL is always ready to receive such a softwa...

Страница 23: ...C to 23 9 kHz 0 01 dB 48 kHz XLR balanced pin 2 pin 3 20 kOhm 11 kOhm 21 dBu 24 bit 128 x oversampling bitstream 0 9 ms 48 kHz Typ 110 dB 22 Hz to 22 kHz Typ 102 dB 0 0008 1 kHz 1 dBFS 0 0 1 dB 20 Hz...

Отзывы: