- 6 -
TC8116
User's Manual
Rev. 5.6D
DIP Switch Functions
Groups 6 & 7
The DIP switch functions on the TC8116 apply individually to their respective
"A" or "B" board. To activate the function, slide the appropriate switch to the
On (Down or Right) position.
RMTLB: Remote Loopback.
This switch (SW1) initiates the Remote
Loopback function. The composite optic signal is received from optic "RxA" (or
"RxB) and decoded, then looped back to optic "TxA" (or "TxB) for diagnostic
testing.
LOCLB: Local Loopback.
This switch (SW2) initiates the Local Loopback
function. The electrical signal is received and decoded, then looped back to the
transmit pins for diagnostic testing.
SIG GEN: Signal Generator.
This switch (SW3) initiates the built-in signal
generator function. The unit will generate a pulse signal to emulate an electrical
transmission signal. By verifying the "Rx" channel LEDs on the remote unit, the
user may confirm that the local unit's signal is being received.
DIS ALM: Disable Alarm.
This switch (SW4) disables the alarm relay and
buzzer during alarm conditions.
ENB RxB.
Not used - for future release.
INV POL: Inverse Polarity.
Not used - for future release.
BAUD 1 & 2: RS-485 high impedance timer setup switches.
Not used -
for future release.
Figure 3. RS-485 Transition Timer Setup Table
RS-232
RS-485
RS-485
RS-485
RS-422
4.8K
9.6K
19.2K & Above
SW7
Off
On
Off
On
SW8
Off
Off
On
On
Note: SW6 is not used.
1
2
3
4
RMTLB
1 2 3 4 5 6 7 8
LOCLB
SIG GEN
DIS ALM
INV POL
BAUD1
BAUD2
1
2
3
4
RMTLB
1 2 3 4 5 6 7 8
LOCLB
SIG GEN
DIS ALM
INV POL
ENB RxB
BAUD1
BAUD2