background image

- 18 -

TC8116

User's Manual

Rev. 5.6D

Appendix B

Return Policy

To return a product, you must first obtain a Return Material Authorization number from the Customer

Service Department.  If the product’s warranty has expired, you will need to provide a purchase order to
authorize the repair.  When returning a product for a suspected failure, please provide a description of  the
problem and any results of diagnostic tests that have been conducted.

Warranty

Damages by lightning or power surges are not covered under this warranty.

All products manufactured by TC Communications, Inc. come with a five year (beginning 1-1-02)

warranty.  TC Communications, Inc. warrants to the Buyer that all goods sold will perform in accordance
with the applicable data sheets, drawings or written specifications.  It also warrants that, at the time of sale,
the goods will be free from defects in material or workmanship.  This warranty shall apply for a period of
five years from the date of shipment, unless goods have been subject to misuse, neglect, altered or destroyed
serial number labels, accidents (damages caused in whole or in part to accident, lightning, power surge, floods,
fires, earthquakes, natural disasters, or Acts of God.), improper installation or maintenance, or alteration or
repair by anyone other than Seller or its authorized representative.

Buyer should notify TC Communications, Inc. promptly in writing of any claim based upon warranty, and

TC Communications, Inc., at its option, may first inspect such goods at the premises of the Buyer, or may
give written authorization to Buyer to return the goods to TC Communications, Inc., transportation charges
prepaid, for examination by TC Communications, Inc. Buyer shall bear the risk of loss until all goods
authorized to be returned are delivered to TC Communications, Inc. TC Communications, Inc. shall not be
liable for any inspection, packing or labor costs in connection with the return of goods.

In the event that TC Communications, Inc. breaches its obligation of warranty, the sole and exclusive

remedy of the Buyer is limited to replacement, repair or credit of the purchase price, at TC Communications,
Inc.’s option.

To return a product, you must first obtain a Return Material Authorization (RMA) number and RMA form

from the Customer Service Department.  If the product’s warranty has expired, you will need to provide a
purchase order to authorize the repair.  When returning a product for a suspected failure, please fill out RMA
form provided with a description of the problem(s) and any results of diagnostic tests that have been
conducted.  The shipping expense to TC Communications should be prepaid.  The product should be properly
packaged and  insured.  After the product is repaired, TC Communications will ship the product back to the
shipper at TC's cost to U.S. domestic destinations. (Foreign customers are responsible for all shipping costs,
duties and taxes [both ways]. We will reject any packages with airway bill indicating TC communications
is responsible for Duties and Taxes. To avoid Customs Duties and Taxes, please include proper documents
indicating the product(s) are returned for repair/retest).

Содержание TC8116

Страница 1: ...any specifica tion TC Communications Inc reserves the right to change or modify the contents of this manual at any time without prior notification TC8116 8 or 16 CHANNEL ASYNC SYNC FIBER OPTIC MULTIPL...

Страница 2: ...onal 9 RJ 11 to DB25 Female Async Connection Cables 10 Transmission Distances typical 12 Launch Power Sensitivity 12 Fiber Optic Redundancy optional 12 Chapter 2 Installation 13 Unpacking the Unit 13...

Страница 3: ...modeloffers several different interchangeable interfaces such as RS 232 RS 422 RS 485 TTL Dry Contact Relay Analog or Intercom It can be upgraded or reconfigured to virtually any configuration simply...

Страница 4: ...trol that are used Not used for future release optic connectors for B board Optional optic signal status for secondary backup optic electrical signal status for channels 9 through 16 DIP switches for...

Страница 5: ...al at RxB has been lost or is degraded Groups 4 9 Optic status indicators Groups 5 8 Electrical signal channel status indicators Each RJ 11 port at the rear panel has two LEDs on the front panel showi...

Страница 6: ...erator This switch SW3 initiates the built in signal generator function The unit will generate a pulse signal to emulate an electrical transmission signal By verifying the Rx channel LEDs on the remot...

Страница 7: ...ins 3 and 4 are balanced output pins Pin 3 is the positive output RxD while pin 4 is negative RxD Either pin 6 or pin 1 can be Signal Ground Only RS 422 RS 485 Async communications can be used with th...

Страница 8: ...pin 5 on an intercom channel is MIC pin 2 is MIC while pin 4 is SPKR and pin 3 is SPKR Figure 7 RJ 11 Analog and Intercom Pin Assignments Virtual Connection Diagrams TC8116 Rear Panel with 2 wire RS...

Страница 9: ...and off status The diagram below illustrates the virtual pin connections for using the TC8116 as either a dry contact Detector Transmitter or a dry contact Closure Receiver The RJ 11 s pins 4 and 5 a...

Страница 10: ...RJ 11 connector pin assignment pin assignment 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 reversed RJ 11 cable Tx Data Rx Data RTS CTS RJ 11 to DB25 female Async DTE to DCE device to TC8116 RJ 11 connector RJ...

Страница 11: ...sync DCE Adapter 1 2 3 4 5 6 2 14 3 16 1 7 RJ 11 Plug RJ 11 Plug P N 650 02206 01 to TC8116 RJ 11 connector to DTE device pin assignment pin assignment 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 reversed RJ...

Страница 12: ...y 34dBm 850nm 1310nm MM 62 5 125 m LASER 36dBm 1310nm Single Mode 9 125 m Launch power sensitivity and distance are listed for reference only These numbers may vary Fiber Optic Redundancy optional Whe...

Страница 13: ...to power up the unit If your system has ten TC8116 cards the power supply requirement is 10 x 400mA 4 0A Either a power adapter or TC Communications power card can be utilized to supply power to the...

Страница 14: ...esults could be erroneous and confusing Calculating the Loss on the Fiber The fiber optic link and or connectors are frequently the source of various problems Check out the connectors and the integrit...

Страница 15: ...urn SW3 SIG GEN to the Off Up or Right position Local Loopback Test With SW2 LOCLB in the On Right or Down position and a valid electrical signal is present at the RJ 11 the incoming signal on pin 5 o...

Страница 16: ...rface RS 232 RS 422 RS 485 TTL Dry Contact Relay Analog or Intercom TTL Input Voltage Maximun Rating 0 5 to 7V Recommended TTL Input Voltage Vin High 2 0V to 5V Vin Low 0V to 0 8V System Bit Error Rat...

Страница 17: ...91 is used for multiplexers and the Model TCRM192 for modems Both can operate with one power supply or dual load sharing power supplies The AC power supply automatically adjusts for 90V to 264V AC inp...

Страница 18: ...irst inspect such goods at the premises of the Buyer or may give written authorization to Buyer to return the goods to TC Communications Inc transportation charges prepaid for examination by TC Commun...

Отзывы: