TRU-THERM
™
INSTALLATION & OWNERS MANUAL
8
•
It is very important that the top of each track is at the same level (shim if
necessary). See table below.
Door Type
Lintel to top of lower/vertical track
Standard Lift
180-190mm below lintel
High Lift
Amount of lift-380= measurement
above
lintel
Vertical Lift
200-210mm above lintel
•
Ensure the tracks are angled further apart at the top than at the bottom to ensure
the door is guided to a central location as it closes. See Figure F below.
Dimension B should be: Dimension A plus 20mm (10mm each side).
•
Also ensure the tracks are angled back as shown in Figure G below. Dimension D
should be: at least Dimension C plus 25mm; or as far back as the slots in the top
TL bracket will allow. If the tracks are not angled back, the door seals will be
rubbing all the time.
B
A
FIGURE F
FIGURE G