![TBB power Kinergier Pro Series Скачать руководство пользователя страница 46](http://html2.mh-extra.com/html/tbb-power/kinergier-pro-series/kinergier-pro-series_manual_4375271046.webp)
Kinergier Pro User Manual
41
6.2.3 BMS Warning
No.
Warning Code
Description
050
Module_HV
Lithium battery module is over voltage.
051
Module_LV
Lithium battery module is under voltage.
052
Module_HT
Lithium battery module's temperature is too high.
053
Module_LT
Lithium battery module's temperature is too low.
054
Discharge_HC
Lithium battery module's discharge current is over normal
value.
055
Charge_HC
Lithium battery module's charge current is over normal
value.
056
INT_Comm Fail
Communication with inverter is abnormal.
057
EXT_Comm Fail
Communication among Lithium modules is abnormal.
058
SOC_Low
Lithium module's SOC is too low.
6.2.4 BGK Warning
No.
Warning Code
Description
601
U_BAT_OV
Battery over voltage alarm.
602
U_BAT_LV
Battery under voltage alarm.
603
U_BAT_Unbalance
Individual Battery Block/Cell Voltage unbalance.
605
Module_T_BAT_OT
Battery low temperature.
606
Module_NTC_Fault
NTC fails
607
Module_MisMatch
Battery Cell voltage does not match.
608
Module_Init_Err
Communication address error.
609
Module_Comm_Err
Communication error with inverter.
610
Module_INT_Err
Communication error among BGK modules.
611
SYS_Init Timeout
System initialization error.
Содержание Kinergier Pro Series