Kinergier Pro User Manual
30
Error Shielding
Item
Setting range
Description
ACin_LV Warn
0-Display
1-Shield
Whether to hide the ACin_LV
Warning. For the UPS application, it
is recommended to enable this
alarm.
Default
: 1-Shield
MPPT Offline
0-Display
1-Shield
Whether to hide the offline warning
of Solar Mate MPPT.
Default
: 0-Display
PV_INV Offline
0-Display
1-Shield
Whether to hide the offline warning
of IG PV inverter.
Default
: 1-Shield
5.6 User control
Using this menu, user can configure some working logic for this Kinergier Pro inverter. This
feature is only applicable for the Master unit.
ACin Logic
Relay Logic
ACout 2 Logic
>ACin Logic
Relay Logic
>ACout2 Logic
Screen Set
>Date & Time
Trigger Command
>User Control
5.6.1 ACin Logic
With this menu, you could set up the working logic for Kinergier Pro working at different
applications.
Item
Setting range
Description
ACin_CHG_Derate
ACin_CHG_Nor
mal
This setting is designed for users to configure the
charging current of the inverter in AC charging.
Default:
100%
ACin_CHG_BAT
_LV
This setting is designed for user to configure the
charging current of the inverter in battery low voltage.
Default:
100%
Working Mode
0-ACin First
1- BATT First
2-Time Ctrl
3-Ubat / SOC
Ctrl
4-ACin Backup
0- ACinFirst
:
Under this mode, the grid will supply load first and
charge the battery at the same time. Kinergier Pro will
switch to battery only when the grid fails.
1- BATT First: