OPERATING PROCEDURES
6-19
PH61 Peristaltic Pump
Operating Procedures
6
Cleaning and Sanitizing
1.
Prepare a 2.5 gal. (9.5 L) pail of a cleaning/sanitizing
solution with an active chlorine concentrate of 100 to
200 ppm approved for use by your company. Use
warm water and follow the cleaning/sanitizing
solution manufacturer's specifications.
2.
Pour the solution into the hopper and allow it to flow
into the freezing cylinder.
3.
Using the white hopper brush, clean the mix hopper,
mix-level sensing probes and the outside of the
agitator driveshaft housing. Using the double-ended
brush, clean the mix inlet hole.
Note: Do not brush-clean the mix inlet hole while
the machine is in the Wash mode.
4.
Press the WASH key. This will cause the cleaning
solution in the freezing cylinder to come in contact
with all areas of the freezing cylinder.
5.
Place an empty pail beneath the door spout.
6.
Open the draw valve on the freezer door and draw off
all the solution.
7.
Once the cleaning solution stops flowing from the
door spout, close the draw valve and press the
WASH key, canceling the Wash mode.
8.
Prepare 2.5 gal. (9.5 L) of cleaning/sanitizing
solution.
Repeat steps 2 through 7 with the sanitizing
solution
.
Disassembly
Note:
Failure to remove the parts specified below for
brush-cleaning and lubrication will damage the machine.
These parts must be removed every 14 days or the
machine will lock out and will not operate.
WARNING!
Make sure the power switch is in
the OFF position. Failure to follow this instruction may
result in severe personal injury from hazardous moving
parts.
Figure 6-70
In order for the control to recognize that the machine has
been brush-cleaned, the following criteria must be met:
•
All freezing cylinder and hopper temperatures
must be above 60°F (16°C).
•
The Mix Out and Mix Low probes must not be
satisfied.
•
The power switch must remain in the OFF
position for at least 5 minutes.
Note:
These criteria must be met simultaneously.
These criteria will be met when the machine is properly
brush-cleaned.
The following screen is displayed if the machine is not in
a brush-clean state. (See Figure 6-71.) If any of the
requirements for a brush-clean have not been met, the
time displayed will remain at 5:00 minutes.
Figure 6-71
13003
POWER SWITCH OFF
OUT
TIME: 4:40
OUT
68.5
HOPPER
62.1
69.5
BARREL
67.7
Содержание PH61
Страница 8: ...1 4 TO THE INSTALLER PH61 Peristaltic Pump To the Installer 1 Notes ...
Страница 14: ...3 4 SAFETY PH61 Peristaltic Pump8 Safety 3 Notes ...
Страница 32: ...5 10 USER INTERFACE PH61 Peristaltic Pump User Interface 5 Notes ...
Страница 56: ...6 24 OPERATING PROCEDURES PH61 Peristaltic Pump Operating Procedures 6 Notes ...
Страница 64: ...9 2 PARTS REPLACEMENT SCHEDULE PH61 Peristaltic Pump Parts Replacement Schedule 9 Notes ...
Страница 68: ...10 4 LIMITED WARRANTY ON EQUIPMENT PH61 Peristaltic Pump Limited Warranty on Equipment 10 Notes ...
Страница 72: ...11 4 LIMITED WARRANTY ON PARTS PH61 Peristaltic Pump Limited Warranty on Parts 11 Notes ...