![Taylor PH61 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/taylor/ph61/ph61_operators-manual_822773047.webp)
OPERATING PROCEDURES
6-15
PH61 Peristaltic Pump
Operating Procedures
6
Syrup Calibration and Priming
Syrup Calibration
Calibrating the syrup flow should be performed weekly
when the syrup system is cleaned. It is vital that the
correct amount of syrup be incorporated into the mix to
obtain a quality shake. To determine the rate of syrup
flow, you will need a calibration cup indicating fluid
ounces.
If thin syrup is being used, the proper rate of syrup flow is
1 oz. (30 ml) of syrup in 5 seconds. If thick syrup is being
used, the proper rate of syrup flow is 1 oz. (30 ml) of
syrup in 7 seconds.
Once this rate is set, the correct amount of syrup will be
blended with the shake base regardless of the size of
shake served. Please note that syrup calibration is critical
when changing the promotional fourth flavor syrup.
Figure 6-57
Calibration Procedure
1. Disconnect the syrup valve from the freezer door.
Raise the syrup valve retainer and pull the valve
straight out. (See Figure 6-58.)
Figure 6-58
2. Hold an empty cup under the syrup valve.
Figure 6-59
3. Push the corresponding syrup flavor key. The light
should be illuminated. (See Figure 6-60.)
Figure 6-60
23034
23006
13012
Содержание PH61
Страница 8: ...1 4 TO THE INSTALLER PH61 Peristaltic Pump To the Installer 1 Notes ...
Страница 14: ...3 4 SAFETY PH61 Peristaltic Pump8 Safety 3 Notes ...
Страница 32: ...5 10 USER INTERFACE PH61 Peristaltic Pump User Interface 5 Notes ...
Страница 56: ...6 24 OPERATING PROCEDURES PH61 Peristaltic Pump Operating Procedures 6 Notes ...
Страница 64: ...9 2 PARTS REPLACEMENT SCHEDULE PH61 Peristaltic Pump Parts Replacement Schedule 9 Notes ...
Страница 68: ...10 4 LIMITED WARRANTY ON EQUIPMENT PH61 Peristaltic Pump Limited Warranty on Equipment 10 Notes ...
Страница 72: ...11 4 LIMITED WARRANTY ON PARTS PH61 Peristaltic Pump Limited Warranty on Parts 11 Notes ...