![Taylor PH61 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/taylor/ph61/ph61_operators-manual_822773031.webp)
USER INTERFACE
5-9
PH61 Peristaltic Pump
User Interface
5
Screen G is HEAT CYCLE DATA.
The information from
the previous Heat Treatment cycles can be obtained
through this screen. The most recent Heat Treatment
cycle data will be shown first. Press the plus key to scroll
through the remaining Heat cycle displays. If a Heat
Treatment cycle failure should occur, a two-character
message will appear on the second line of the screen.
Press the SEL key to return to the OPERATOR MENU.
Listed below are the various messages which could
appear:
Pressing the left arrow key on any HEAT CYCLE DATA
screen will cause the extended data screen to be
displayed. This screen shows the hopper, barrel, and
glycol temperatures, and the amount of time the machine
spent in the phases of the Heat cycle when the Heat
cycle completed or was terminated.
Pressing the SEL key returns the display to the
OPERATOR MENU.
Screen H is the LOCKOUT HISTORY.
This screen
displays a history of the last 40 hard locks, soft locks, and
brush-clean dates. Page numbers are indicated in the
upper right-hand corner. Page 1 contains the most recent
failure. Press the plus key to cycle through the pages.
The second line of the screen displays the date and time
a failure occurred. The third line indicates the reason for
a failure or will indicate that a successful brush-cleaning
has occurred. Some failures occur for multiple reasons.
When this happens, a page will be generated for each
reason. Press the SEL key to return to the OPERATOR
MENU.
Screen I is the AUTO START TIME
. This screen allows
the operator to enable or disable AUTO START TIME. If
enabled, the operator sets the time at which the machine
will automatically enter Auto mode from Standby mode.
The machine will only enter Auto mode under the
following conditions: If the programmed Auto Start Time
has been reached, the machine is in Standby, no soft lock
or hard lock conditions exist, and the Auto Start Time
feature has been enabled.
Use the arrow keys to move the cursor left or right. Use
the plus and minus keys to change the time setting.
Press the SEL key to save the selection and return to the
OPERATOR MENU.
Screen J is the SERVICE MENU.
This screen can only
be accessed by a service technician.
Screen K is the STANDBY MODE.
This option allows
the operator to manually place the machine into Standby.
Pressing the SEL key with the cursor under YES places
the machine in Standby mode and returns to the
OPERATOR MENU.
HT
Heat time too long
CL
Cool time too long
TT
Failure in meeting total Heat Treatment
cycle time requirement
TH
Failed thermistor probe
ML
MIX LOW condition
MO
MIX OUT condition
BO
Beater overload
HO
High-pressure cut-out
PF
Power failure
Note:
If a power failure occurs but the
Heat Treatment cycle does not fail, an
asterisk (*) will appear on the third line of the
display.
OP
Operator interruption
PS
Power switch in the OFF position
RC
Heat cycle record cleared
00/00
00:00
00:00
HEAT
OVER
COOL
XX
01:09
00:45
01:14
TEMP AT END
38.5
1
HOPPER
BARREL
GLYCOL
151.0
134.5
178.0
PHASE TIME: 1:20
1
LOCKOUT HISTORY
1
11/21/14
02:08
SOFTLOCK ABORT
+++
- - -
SEL
STANDBY MODE
STANDBY
YES
NO
- - -
L
E
S
>
-
-
-
-
-
-
<
Содержание PH61
Страница 8: ...1 4 TO THE INSTALLER PH61 Peristaltic Pump To the Installer 1 Notes ...
Страница 14: ...3 4 SAFETY PH61 Peristaltic Pump8 Safety 3 Notes ...
Страница 32: ...5 10 USER INTERFACE PH61 Peristaltic Pump User Interface 5 Notes ...
Страница 56: ...6 24 OPERATING PROCEDURES PH61 Peristaltic Pump Operating Procedures 6 Notes ...
Страница 64: ...9 2 PARTS REPLACEMENT SCHEDULE PH61 Peristaltic Pump Parts Replacement Schedule 9 Notes ...
Страница 68: ...10 4 LIMITED WARRANTY ON EQUIPMENT PH61 Peristaltic Pump Limited Warranty on Equipment 10 Notes ...
Страница 72: ...11 4 LIMITED WARRANTY ON PARTS PH61 Peristaltic Pump Limited Warranty on Parts 11 Notes ...