6-12
OPERATING PROCEDURES
PH61 Peristaltic Pump
Operating Procedures
6
11. With sanitized hands, remove the syrup valve pin
retainer and the syrup valve retainers. Brush-clean
the empty orifices. Replace the syrup valve retainers
and install the syrup valve pin retainer.
12. Fill the squeeze bottle with cleaning/sanitizing
solution. With a pail beneath the door, insert the tube
end of the squeeze bottle into the syrup valve
retainer holes and the syrup port. Squeeze the bottle
firmly. This action will force solution out of the
adjacent port and down around the spinner. This
procedure should be performed for at least
10 seconds per port. (See Figure 6-47.)
Figure 6-47
13. Place the spout cap O-ring in the spout cap. Fill the
spout cap with the cleaning/sanitizing solution. While
holding the draw valve closed, install the spout cap
over the end of the door spout. This will cause the
solution to backflow through the syrup ports.
Figure 6-48
14. Install the syrup-hole plugs in the syrup ports in the
freezer door. (See Figure 6-49.)
Figure 6-49
15. Remove, clean, and re-install the long drip pan
through the front panel.
16. Install the short drip pan in the rear panel.
17. Use a clean, sanitized towel to wipe down the freezer
door and area around the bottom of the freezer door.
The Heat cycle will start when the clock on the
machine reaches the AUTO HEAT TIME set in the
OPERATOR MENU (see page 5-8).
There are three phases of the Heat cycle: Heat, Hold,
and Cool. Each phase has a time limit. If any one of the
three phases fails to reach the proper temperatures
within the time limit, the cycle will automatically abort and
return to the Standby mode. The LCD will display the
message: HEAT TREAT CYCLE FAILURE - FREEZER
LOCKED - PRESS SEL KEY. The product may not be
safe to serve. The machine will be locked out (soft lock)
of the Auto mode. The operator will be given the option of
pressing the AUTO key, which will begin a new Heat
cycle, or pressing the WASH key, which will place the
machine in the OFF mode to allow a
brush-cleaning of the machine.
Note:
Once the Heat cycle has started, it cannot be
interrupted. The Heat cycle will take a maximum of
4 hours to complete with a full hopper.
WARNING!
DO NOT
attempt to draw product or
disassemble the machine during the Heat Treatment
cycle (if equipped). The product is hot and under extreme
pressure. Severe burns from hot product may result if this
instruction is not followed.
When the Heat cycle is complete, the control will return to
the Standby mode.
23005
23019
23007
Содержание PH61
Страница 8: ...1 4 TO THE INSTALLER PH61 Peristaltic Pump To the Installer 1 Notes ...
Страница 14: ...3 4 SAFETY PH61 Peristaltic Pump8 Safety 3 Notes ...
Страница 32: ...5 10 USER INTERFACE PH61 Peristaltic Pump User Interface 5 Notes ...
Страница 56: ...6 24 OPERATING PROCEDURES PH61 Peristaltic Pump Operating Procedures 6 Notes ...
Страница 64: ...9 2 PARTS REPLACEMENT SCHEDULE PH61 Peristaltic Pump Parts Replacement Schedule 9 Notes ...
Страница 68: ...10 4 LIMITED WARRANTY ON EQUIPMENT PH61 Peristaltic Pump Limited Warranty on Equipment 10 Notes ...
Страница 72: ...11 4 LIMITED WARRANTY ON PARTS PH61 Peristaltic Pump Limited Warranty on Parts 11 Notes ...