background image

1

Models 8752 & 8756 with Horizon

®

Pump

To the Installer

Section 1

To the Installer

The following are general installation instructions. For

complete installation details, please see the check out

card.

Installer Safety

In all areas of the world, equipment should be

installed in accordance with existing local codes.

Please contact your local authorities if you have any

questions.

Care should be taken to ensure that all basic safety

practices are followed during the installation and

servicing activities related to the installation and

service of Taylor equipment.

S

Only authorized Taylor service personnel

should perform installation and repairs on

the equipment.

S

Authorized service personnel should consult

OSHA Standard 29CFRI910.147 or the

applicable code of the local area for the

industry standards on lockout/tagout

procedures before beginning any installation

or repairs.

S

Authorized service personnel must ensure

that the proper PPE is available and worn

when required during installation and

service.

S

Authorized service personnel must remove

all metal jewelry, rings, and watches before

working on electrical equipment.

The main power supply(s) to the freezer must

be disconnected prior to performing any repairs.

Failure to follow this instruction may result in personal

injury or death from electrical shock or hazardous

moving parts as well as poor performance or damage

to the equipment.

Note: All repairs must be performed by an

authorized Taylor Service Technician.

This unit has many sharp edges that can

cause severe injuries.

Site Preparation

Review the area the unit is to be installed in before

uncrating the unit making sure that all possible

hazards the user or equipment may come into have

been addressed.

For Indoor Use Only:

This unit is designed to operate

indoors, under normal ambient temperatures of 70

_

- 75

_

F (21

_

- 24

_

C). The freezer has successfully

performed in high ambient temperatures of 104

_

F

(40

_

C) at reduced capacities.

This unit must

NOT

be installed in an area

where a water jet or hose can be used.

NEVER

use a

water jet or hose to rinse or clean the unit. Failure to

follow this instruction may result in electrocution.

This unit must be installed on a level surface

to avoid the hazard of tipping. Extreme care should be

taken in moving this equipment for any reason. Two or

more persons are required to safely move this unit.

Failure to comply may result in personal injury or

equipment damage.

Uncrate the unit and inspect it for damage. Report any

damage to your Taylor Distributor.

This piece of equipment is made in the USA and has

USA sizes of hardware. All metric conversions are

approximate and vary in size.

Air Cooled Units

DO NOT

obstruct air intake and discharge openings:

Air cooled units require a minimum of 3” (76 mm) of

clearance around

all

sides of the freezer and 12” (305

mm) on top to allow for adequate air flow across the

condenser(s). Failure to allow adequate clearance can

reduce the refrigeration capacity of the freezer and

possibly cause permanent damage to the compressor.

Содержание Horizon 8752

Страница 1: ...Models 8752 8756 Horizon Pump Soft Serve Freezers Operating Instructions 028752HPM 11 17 09 ...

Страница 2: ...l Number Electrical Specs Voltage Cycle Phase Maximum Fuse Size Amps Minimum Wire Ampacity Amps Part Number E November 2009 Taylor All rights reserved 028752HPM The word Taylor and the Crown design are registered trademarks in the United States of America and certain other countries Taylor Company a division of Carrier Commercial Refrigeration Inc 750 N Blackhawk Blvd Rockton IL 61072 ...

Страница 3: ...r 4 Compressor Warranty Disclaimer 4 Section 3 Safety 5 Section 4 Operator Parts Identification 7 Model 8752 7 8752 Beater Door Assembly 9 Model 8756 10 8756 Beater Door Assembly 12 HorizonR Mix Delivery Pump 13 Accessories 14 Section 5 Important To the Operator 15 Symbol Definitions 15 Power Switch 16 Indicator Lights Mix Low and Mix Out 16 Reset Button 16 Softech Control Operation 16 Mix Ref 16 ...

Страница 4: ...Bacterial Count 35 Regular Maintenance Checks 35 The HorizonR Pump 36 Winter Storage 36 Section 8 Troubleshooting Guide 37 Section 9 Parts Replacement Schedule 42 Section 10 Parts List 43 Wiring Diagrams 59 Note Continuing research results in steady improvements therefore information in this manual is subject to change without notice E November 2009 Taylor All rights reserved 028752HPM The word Ta...

Страница 5: ... repairs must be performed by an authorized Taylor Service Technician This unit has many sharp edges that can cause severe injuries Site Preparation Review the area the unit is to be installed in before uncrating the unit making sure that all possible hazards the user or equipment may come into have been addressed For Indoor Use Only This unit is designed to operate indoors under normal ambient te...

Страница 6: ...ther areas of the world equipment should be installed in accordance with the existing local codes Please contact your local authorities FOLLOW YOUR LOCAL ELECTRICAL CODES Each freezer requires one power supply for each data label Check the data label s on the freezer for fuse circuit ampacity and electrical specifications Refer to the wiring diagram provided inside of the control box for proper po...

Страница 7: ...igerant used in this unit is R404A This refrigerant is generally considered non toxic and non flammable with an Ozone Depleting Potential ODP of zero 0 However any gas under pressure is potentially hazardous and must be handled with caution NEVER fill any refrigerant cylinder completely with liquid Filling the cylinder to approximately 80 will allow for normal expansion Refrigerant liquid sprayed ...

Страница 8: ...August 13 2005 Therefore it must be collected separately after its use is completed and cannot be disposed as unsorted municipal waste The user is responsible for returning the product to the appropriate collection facility as specified by your local code For additional information regarding applicable local laws please contact the municipal facility and or local distributor Compressor Warranty Di...

Страница 9: ...these instructions may result in serious electrical shock S DO NOT operate the freezer unless it is properly grounded S DO NOT operate the freezer with larger fuses than specified on the freezer data label S DO NOT attempt any repairs unless the main power supply to the freezer has been disconnected Contact your local authorized Taylor Distributor for service S Stationary appliances which are not ...

Страница 10: ...harp This freezer must be placed on a level surface Failure to comply may result in personal injury or equipment damage Cleaning and sanitizing schedules are governed by your state or local regulatory agencies and must be followed accordingly Please refer to the cleaning section of this manual for the proper procedure to clean this unit DO NOT obstruct air intake and discharge openings 3 76 mm min...

Страница 11: ...7 Models 8752 8756 with Horizon Pump Operator Parts Identification Section 4 Operator Parts Identification Model 8752 Figure 1 ...

Страница 12: ...WV 3 4 10 ST 3IN WHEEL 021279 10 GASKET CAB MIX DOOR 020134 11 TRIM FRONT R 024825 12 PROBE A MIX X35981 13 TRIM BOTTOM MIX DOOR 024974 14 TANK MIX 020275 ITEM DESCRIPTION PART NO 15 FUNNEL MIX 036637 16 COVER MIX TANK X38726 17 BOOT MIX COVER 037200 18 COVER MIX STORAGE CENTER SINGLE 038827 19 TRAY DRIP 020157 20 SHIELD SPLASH 23 LONG 022765 21 TRIM FRONT L 024824 SP 22 TRIM MIX DOOR 024976 23 TR...

Страница 13: ...47 7 SHOE FRONT HELIX REAR 050346 8 BEARING FRONT SHOE 050348 9 GASKET DOOR HT 4 DBL 048926 10 PLUG PRIME 028805 11 O RING 3 8 OD X 070W 016137 12 DOOR A 1 SPOUT X49460 3 ITEM DESCRIPTION PART NO 13 HANDLE A DRAW ADJ X55096 13a HANDLE ADJUSTABLE 028804 13b SCREW ADJUSTMENT 055092 13c O RING 1 4 OD X 070W 50 015872 13d NUT JAM 029639 BLK 14 NUT STUD 021508 15 O RING 5 16 OD X 070W 016272 16 PIN A P...

Страница 14: ...10 Models 8752 8756 with Horizon Pump Operator Parts Identification Model 8756 Figure 3 ...

Страница 15: ...GHT 024825 11 PROBE A MIX X35981 12 GASKET CAB MIX DOOR 024629 13 TANK A MIX W DECALS X38755 SER 13a TANK MIX 9 GALLON TAPERED BTM 034928 ITEM DESCRIPTION PART NO 14 FUNNEL MIX 036637 15 COVER MIX TANK 024590 16 COVER MIX STORAGE RIGHT 037139 17 COVER MIX STORAGE LEFT 037138 18 BOOT MIX COVER 037200 19 TRAY DRIP 014533 20 SHIELD SPLASH 23 LONG 022766 21 TRIM BOTTOM CABINET 024826 22 TRIM FRONT LEF...

Страница 16: ...9 GASKET DOOR HT 4 DBL 048926 10 ROD A PIVOT LONG X22387 11 O RING 5 16 OD X 070W 016272 12 VALVE A DRAW X18303 13 O RING 7 8 OD X 103W 014402 14 CAP DESIGN 1 010 ID 6 PT 014218 ITEM DESCRIPTION PART NO 15 VALVE A DRAW CENTER X37376 16 SEAL DRAW VALVE 034698 17 NUT STUD LONG 034382 18 NUT STUD SHORT 034383 19 PLUG PRIME 028805 20 O RING 3 8 OD X 070W 016137 21 DOOR A 3SPT LG BAF X49461 10 22 HANDL...

Страница 17: ...IR SUPPLY 24 X34654 9 HOUSING REAR PUMP 051886 10 NUT 10 32 ACORN CUP NUT 035251 11 PLATE RETAINING PIN 066483 12 TUBE PUMP PERISTALTIC 053891 13 SCREW 10 32 x 1 2 SLTD 001251 ITEM DESCRIPTION PART NO 14 FITTING PUMP TUBE 066482 15 O RING 3 4 OD x 103 W 015835 16 POPPET RUBBER BLACK 022473 17 SPRING TAPERED 1 7 8 L 022456 18 FITTING INLET PRESS VALVE 066481 19 TUBE A SUCTION X20450 19a COUNTERWT S...

Страница 18: ... 6 BRUSH DRAW VALVE 013073 7 LUBRICANT TAYLOR 4 OZ 047518 8 SANITIZER KAY 5r 125 PKTS 041082 ITEM DESCRIPTION PART NO 9 SANITIZER STERA SHEEN 065293 10 PAIL MIX 10 QT 013163 KIT A TUNE UP 8752 X49463 37 KIT A TUNE UP 8756 X49463 36 KIT A TUNE UP PUMP 8752 X53079 4 KIT A TUNE UP PUMP 8756 X53079 5 Not Shown Note A sample container of sanitizer is sent with the unit For reorders order Stera Sheen pa...

Страница 19: ...Refrigeration Control 4 STANDBY Key 5 WASH Key 6 AUTO Key 7 PUMP Key 8 Mix Low Indicator 9 Mix Out Indicator Symbol Definitions To better communicate in the International arena the words on many of our operator switches and buttons have symbols to indicate their functions Your Taylor equipment is designed with these International symbols AUTO ON OFF MIX REF WASH PUMP STANDBY MIX LOW MIX OUT ...

Страница 20: ...re to follow this instruction may result in serious electrical shock If the freezer shuts down again contact your authorized service technician Softech Control Operation Mix Ref When the MIX REF key is pressed the light comes on indicating the mix cabinet refrigeration system is operating For the Model 8756 there are two touch tone panels one for each freezing cylinder The mix refrigeration system...

Страница 21: ...ts feature an adjustable draw handle to provide the best portion control giving a better consistent quality to your product and controlling costs The draw handle should be adjusted to provide a flow rate of 5 to 7 1 2 oz of product by weight per 10 seconds To increase the flow rate turn the screw counterclockwise To decrease the flow rate turn the screw clockwise IMPORTANT When dispensing product ...

Страница 22: ... morning and find the parts laid out to air dry from the previous night s brush cleaning If you are disassembling the machine for the first time or need information to get to this starting point in our instructions turn to page 33 Disassembly and start there Assembly MAKE SURE CONTROL SWITCH IS INTHE OFF POSITION Step 1 To install the drive shaft lubricate the groove and shaft portion that comes i...

Страница 23: ...nt holding pin Figure 12 Install the beater shoes Figure 13 Make sure the beater assembly is in position over the drive shaft Turn the beater slightly to be certain that the beater is properly seated When in position the beater will not protrude beyond the front of the freezing cylinder Repeat Steps 1 and 2 for the other side of the freezer on the Model 8756 Step 3 Assemble the freezer door Place ...

Страница 24: ... 16 Step 4 Install the freezer door s Insert the baffle rod s through the beater s in the freezing cylinder s With the door seated on the freezer studs install the handscrews Tighten equally in a criss cross pattern to insure the door is snug Note On the Model 8756 the short handscrews go on the bottom and the long handscrews go on the top Figure 17 Step 5 Install the draw valve s Slide the two o ...

Страница 25: ...ins Slide the fork of the draw handle in the slot of the draw valve starting from the right Slide the long pivot pin through the right and middle draw handles Secure the left draw handle with the short pivot pin The draw handles have a color identifier for vanilla twist and chocolate Be sure to install the appropriate handle in the correct position Figure 21 Note These units feature adjustable dra...

Страница 26: ...d mix and transfer this combination to the freezing cylinder Refer to the illustration on page 13 for identification of parts during assembly Step 1 Lightly lubricate both sides of the pressure switch diaphragm Note Do not place the diaphragm in the pressure switch cap Figure 25 Step 2 Place the diaphragm on the front face of the pressure switch housing and then screw the pressure switch cap onto ...

Страница 27: ...lve and lubricate Figure 28 Step 5 Place the rubber poppet in one end of the spring Do not lubricate the rubber poppet Figure 29 Step 6 Attach the opposite end of the spring onto the inlet fitting of the check valve body Figure 30 Step 7 Place the cap over the spring and poppet Secure the cap to the check valve body by inserting the locking pin Figure 31 ...

Страница 28: ... line to the air compressor fitting and the other end to the air inlet fitting of the check valve assembly Figure 33 Step 10 Install the o ring on both of the pump tube fittings and lightly lubricate Figure 34 Step 11 Place an o ring on the valve inlet fitting and lightly lubricate Figure 35 Step 12 Place the black rubber poppet into the small end of the tapered spring and assemble the spring onto...

Страница 29: ... the main pump assembly Figure 38 Step 15 Secure the pressure relief assembly by installing the retaining pin into the rear retaining pin plate Figure 39 Note The assembled parts must align with the matching hole in the mounting plate Step 16 Attach one end of the flare line to the pressure relief valve outlet fitting of the Horizon pump Attach the other end to the mix feed tube Figure 40 ...

Страница 30: ...o hang free Figure 41 Step 18 Assemble the mix suction line Attach the weighted end to one opening of the suction tube Figure 42 Step 19 Attach the open end of the mix suction tube to the pressure relief inlet fitting of the Horizon pump Figure 43 Step 20 Insert the free end of the suction line and the pressure line into the pail of sanitizing solution Figure 44 Repeat Steps 1 through 20 for the o...

Страница 31: ...izing solution to be pumped through the pump and out through the pressure line After approximately 15 seconds press the PUMP key The light will go out and the pump will stop operation Figure 45 Step 4 Drain and connect the free end of the pressure line to the check valve Figure 46 Step 5 Place an empty pail beneath the door spout and raise the prime plug Figure 47 Press the WASH and PUMP keys The ...

Страница 32: ...heck valve Drain the sanitizer Reconnect the pressure line to the check valve Repeat Steps 1 through 8 for the second freezing cylinder on the Model 8756 Air Flow Adjustment Adjust air flow prior to priming the unit with mix Step 1 Open the prime plug Figure 50 Step 2 Make sure the suction line is open to air flow and is not inserted in liquid Step 3 Press the PUMP key Step 4 Adjust the air flow t...

Страница 33: ...e mix tank and connect the mix probe in the socket receptacle Figure 52 Step 3 Place the free end of the suction line down in the mix tank Figure 53 Step 4 Install the funnel Fill the mix tank with fresh mix Note Use only fresh mix when priming the freezer Figure 54 Step 5 Remove the funnel and install the mix storage cover Close the mix cabinet door Step 6 Place an empty pail beneath the door spo...

Страница 34: ...rigeration system is operating the AUTO light will come on indicating the main refrigeration system is operating and the PUMP light will come on indicating the Horizon pump will operate whenever mix is needed in the freezing cylinder Figure 58 Repeat Steps 1 through 8 for the other side of the freezer on the Model 8756 When the unit cycles off the product will be at the correct viscosity Note Keep...

Страница 35: ...P keys to stop operation S Place a sanitized lid on the rerun container and place it in the walk in cooler Note If local health codes DO NOT permit the use of rerun the product must be discarded Follow the instructions in the previous step except drain the product into a mix pail and properly discard the mix Repeat Steps 3 through 4 for the second freezing cylinder on the Model 8756 ALWAYS FOLLOW ...

Страница 36: ...il the water being discharged is clear Repeat Steps 1 through 9 for the second freezing cylinder on the Model 8756 Cleaning Step 1 Prepare a pail of approved 100 PPM cleaning solution examples 2 1 2 gal 9 5 liters of Kay 5R or 2 gal 7 6 liters of Stera SheenR USE WARM WATER AND FOLLOW THE MANUFACTURER S SPECIFICATIONS Place the pail of cleaning solution inside the mix cabinet and insert the suctio...

Страница 37: ...e pressure relief valve and disassemble Repeat Steps 2 through 7 for the other side of the freezer on the Model 8756 Step 8 Remove the front drip tray and splash shield Brush Cleaning Step 1 Prepare a sink with an approved cleaning solution examples Kay 5R or Stera SheenR USE WARM WATER AND FOLLOW THE MANUFACTURER S SPECIFICATIONS IMPORTANT Follow the label directions Too STRONG of a solution can ...

Страница 38: ...ANT S DO NOT insert a brush into the pump tube S DO NOT remove the pump tube when cleaning the unit Note The pump tube is located inside of the Horizon pump See illustration on page 13 Step 9 Remove the rear drip pan from the side panel and take it to the sink for cleaning Note If the rear drip pan is filled with an excessive amount of mix refer to the Troubleshooting Guide Step 10 Thoroughly brus...

Страница 39: ...nitized covered stainless steel container and is used the following day DO NOT prime the machine with rerun When using rerun skim off the foam and discard then mix the rerun with fresh mix in a ratio of 50 50 during the day s operation j 6 On a designated day of the week run the mix as low as feasible and discard after closing This will break the rerun cycle and reduce the possibility of high bact...

Страница 40: ...ith a soft brush Never use screwdrivers or other metal probes to clean between the fins The Horizon Pump Figure 66 Replace the Horizon pump tubing every three months Winter Storage If the place of business is to be closed during the winter months it is important to protect the freezer by following certain precautions particularly if the building is subject to freezing conditions Disconnect the fre...

Страница 41: ...ezing cylinder e Refer to problem 2 f Restriction in the door spout f Remove the draw handle and raise the draw valve all the way up to remove restriction Never put objects or fingers in door spout g Machine is unplugged g Plug machine into the wall receptacle h Circuit breaker is off or the fuse is blown h Turn the breaker on or replace the fuse i The mix probe was not installed properly or was d...

Страница 42: ...e Use the long flexible brush and sanitizing solution to clear the restriction in the mix inlet tube Contact a service technician to correct the cause of over refrigeration in the mix cabinet f The mix pump is pumping foam f Incorrect handling of rerun Must remove all foam 35 3 Product is too stiff a Viscosity control is set too cold a Contact a service technician b Insufficient mix in the freezin...

Страница 43: ... 12 30 5 cm clearance on top of freezer 1 5 Mix in the mix cabinet is too warm a Warm mix was placed in the tank a Mix added to the mix tank should be below 40_F 4 4_C 35 b The mix cabinet door was left open b The door must be kept closed 29 c The mix cabinet refrigeration system needs adjustment c Contact a service technician d The mix cabinet door gasket is not sealing d Repair or replace gasket...

Страница 44: ...ear box b Rounded corners on hex end of drive shaft or gear coupling b Replace damaged component 10 Freezing cylinder walls are scored a Broken pins on beater assembly a Repair or replace the beater assembly Be sure the scraper blades are properly seated on pins 19 b The beater assembly is bent b Repair or replace the beater assembly Contact a service technician to correct the cause of insufficien...

Страница 45: ...e fuse c Low on mix The MIX OUT light is flashing c Add mix to the mix tank and press the AUTO key 15 d The mix probe is not installed properly or is damaged d Check the mix probe installation 29 e The beater motor is out on reset e Reset the freezer 15 f The unit is off on high head pressure f Air cooled clean the condenser Water cooled check the water supply Contact a service technician 36 g The...

Страница 46: ...gn Cap X 1 Horizon Pump Tube X White Bristle Brush 9 16 x 44 Inspect Replace if Necessary Minimum 1 White Bristle Brush 1 x 2 Inspect Replace if Necessary Minimum 1 White Bristle Brush 3 x 7 Inspect Replace if Necessary Minimum 1 White Bristle Brush 3 x 1 2 Inspect Replace if Necessary Minimum 1 Small White Bristle Brush Inspect Replace if Necessary Minimum 1 Double Ended Brush Inspect Replace if ...

Страница 47: ...103 208 230V 60HZ 3PH BLOCK TERMINAL 5P 20A 300V 024329 1 103 BLOCK TERMINAL 3P 25 SPADE 057201 1 103 BLOWER A STANDARD OUTPUT X53725 27 1 103 CAPACITOR RUN 7 5UF 370V 034749 1 103 BOOT CAPACITOR INSULATING 031314 1 000 MOTOR FAN 208 230V 50 60 HZ 053481 27 1 103 SCREEN BLOWER 053729 1 103 BOARD LOGIC GEN 2 10 W SEL D X36641SER2 2 212 8756 S N K9012374 UP BOARD LOGIC GEN 2 9 HOPR PMP X42002SERP 1 ...

Страница 48: ...P 055404 1 2 103 TUBE VINYL 1 8 ID X 1 4 OD R30301 5 5 000 BULK R30301 DRAIN VALVE RELIEF 30 PSI 1 8 MPT 039365 1 1 103 VALVE SOLENOID 7 32ORF X 1 4FP 065375 27 2 103 S N K7033294 AND UP VALVE SOLENOID 7 32 ORF X 1 4 FP 047496 27 103 S N K7033293 PRIOR COMPRESSOR L64A113BBCA BRISTOL 048259 27E 1 2 512 208 230V 60HZ 1PH CAPACITOR RUN 25UF 440V 037431 1 2 103 CAPACITOR START 189 227UF 33 033044 1 1 ...

Страница 49: ...3732 UP 138 COVER A MIX TANK SINGLE NEW X53268 1 103 LEFT SIDE 8756 J9013732 UP 138 COVER MIX TANK 024590 103 8756 PRIOR TO J9013732 COVER MIX STORAGE LEFT 037138 1 103 COVER MIX STORAGE RIGHT 037139 1 103 BOOT MIX COVER 037200 2 000 DECAL INST CLN CAB PERISTAL 053339 1 1 000 REPLACES 024735 141 DECAL DEC TAYLOR 033227 1 000 DECAL DEC TAYLOR 032424 1 000 DECAL DOOR HORIZON 052392 1 1 000 MIX CABIN...

Страница 50: ...2 2 000 KIT A BEATER FRONT SHOES X50350 1 000 DOOR A 3 SPOUT X51532 12 1 103 INCLUDES DECAL 021521 BEARING FRONT SHOE 050348 2 000 GASKET DOOR 4 SHELL 048926 2 000 HANDLE A DRAW ADJUSTABLE X55096 3 103 O RING 1 4 OD X 070W 50 DURO 015872 3 000 SCREW ADJUSTMENT STAINLESS 033662 3 000 NUT 5 16 24 18 8 SS JAM 029639 BLK 3 000 PLUG PRIME 028805 2 103 O RING 3 8 OD X 070W 016137 4 000 PRIME PLUG ROD A ...

Страница 51: ...RE VALV 066480 2 103 S N K9012374 UP FITTING PUMP TUBE HORIZON 066482 4 103 S N K9012374 UP FITTING PUMP INLET 053242 103 8756 PRIOR TO J9013732 FITTING PUMP OUTLET 051944 103 8756 PRIOR TO J9013732 FLOWMETER PERISTALTIC PUMP 055404 1 2 103 FUNNEL MIX 036637 1 2 103 FUSE 15 AMP CARTRIDGE 027582 2 4 000 GASKET CAB MIX DOOR 020134 1 000 GASKET CAB MIX DOOR 024629 1 000 GEAR A REDUCER 021286 SER 1 2 ...

Страница 52: ...OVAL FREEZER 048260 WHT 1 000 KIT A TUNE UP HORIZON PUMP X53079 4 1 000 DIAPHRAGM PRESSURE SWITCH 020249 1 000 O RING 13 16 OD X 139W 021278 1 000 POPPET RUBBER BLACK 022473 1 000 SPRING COMP 300X 022X1 25 SS 051941 1 000 TUBE PUMP PERISTALTIC 053891 1 000 KIT A TUNE UP 3 SPOUT NON HT X49463 36 1 000 DRAW VALVE DOOR O RING 3 8 OD X 070W 016137 4 000 PRIME PLUG TOOL 0 RING REMOVAL 048260 WHT 1 000 ...

Страница 53: ...PN 020090 2 000 208 230V 60HZ 3PH LABEL DOOR WARN MOVE PARTS 032749 1 1 000 LABEL WARN MOVE PARTS 052180 SYM 1 2 000 LABEL WARN COVER 051433 7 7 000 LABEL SW POWER OFF ON SYMBOLS 052632 1 1 000 LINE A AIR INJECTION PERISTAL X51861 1 2 103 ADAPTOR SWV 1 4FFLX1 4 BARB 016715 1 2 103 FERRULE 475 ID NP BRASS 021082 2 4 000 FITTING AIR INJECTION 051862 1 1 103 TUBE NYLOBRADE 1 4ID X 7 16O 020568 25 1 2...

Страница 54: ... 1 1 103 MOTOR FAN 80 WATT 1550 RPM CW NEW 051744 27 1 103 MAIN SYSTEM 8752 J9066372 UP 143 FAN 5 BLADE 12 PUSH 32DEG 047279 1 103 CAPACITOR RUN 4UF 440V 051785 1 103 8752 J9066372 UP 143 BOOT CAPACITOR 031314 1 000 MOTOR FAN 95 3 CFM 2700 RPM 1 1 103 USE X62253 27 KIT A MOTOR FAN MOTOR 1 5 HP 021522 27 1 2 212 208 230V 60HZ 1PH MOTOR 1 5 HP 021522 33 1 2 212 208 230V 60HZ 3PH MOTOR REDUCER SERVIC...

Страница 55: ...OBE 033745 1 1 103 MIX CABINET PULLEY 2AK25 X 625 021076 1 2 103 BEATER MOTOR PULLEY 2AK74 5 8 027822 1 2 103 GEAR PUMP PERISTALTIC ADAPTOR PUMP CABINET PERISTALTIC 051947 1 2 103 FITTING PUMP INLET 5 16 053691 1 103 FITTING INLET PRESSURE VALVE 066481 2 103 S N K9012374 UP FITTING OUTLET PRESS VALVE 064007 1 103 FITTING OUTLET PRESSURE VALV 066480 2 103 S N K9012374 UP FITTING PUMP INLET 5 16 053...

Страница 56: ...4 UP 143 NUT 1 4 20 HEX LOCKING NEW 051887 2 1 2 000 S N J9072394 UP 143 SANITIZER STERA SHEEN GREEN 055492 1 000 100 2OZ PACKETS CS SANITIZER STERA SHEEN GR 010425 1 000 64 OZ PER JAR SANITIZER KAY 5 041082 1 000 CASE OF 125 PACKETS SCREW THUMB 10 32 052016 4 8 000 PUMP HOUSING SHAFT BEATER 032564 1 2 103 SEAL DRIVE SHAFT 032560 1 2 000 SHELL A INSULATED 8752 X24369 SER 1 512 STUD NOSE CONE 02282...

Страница 57: ...RETURN 023488 1 103 SWITCH LEVER SPDT 10A 125 250V 028889 1 103 SWITCH A DRAW TWIN TWIST X38921 1 103 ARM SWITCH DRAW LEFT 038649 1 103 ARM SWITCH DRAW RIGHT 038650 1 103 BRACKET A SWITCH 338 39 754 X38252 1 103 E RING 1 4 032190 2 000 PIN PIVOT DRAW SWITCH 038484 1 103 SPRING RETURN L 023487 1 103 SPRING RETURN R 023488 1 103 SWITCH A DRAW TWIN TWIST X39269 1 103 BRACKET DRAW SWITCH TWIN TWIST 03...

Страница 58: ...103 DECAL MIX TANK WRONG SIDE OUT 038750 2 000 TANK MIX 9 GALLON TAPERED BTM 034928 2 103 TRAY DRIP 16 7 8L X 5 1 8W 020157 1 103 TRAY DRIP 22 7 8L X 5 1 8W 014533 1 103 TRAY PARTS PERISTALTIC PUMP 063800 1 1 000 S N J9013732 UP REPLACES 053269 TRAY PARTS BARREL 3 4 QT 025468 1 000 S N J9013732 UP TRIM A SHELF X20426 1 103 TRIM A SHELF 657 756 X24813 1 103 BELOW DRIP TRAY TRIM A SIDE UPPER X22423 ...

Страница 59: ... 1 4 OD X 2 L 042306 1 103 POPPET RUBBER BLACK 022473 1 000 SOCKET Q D LIQ 1 8 MPT 022159 1 103 SPRING COMP 300X 022X1 25 SS 051941 1 000 VALVE A CHECK PERISTALTIC X51938 2 103 8756 S N K9012374 UP BODY CHECK VALVE PERISTALTI 051945 2 103 CAP VALVE CHECK PERISTALTIC 051946 2 103 O RING 13 16 OD X 139W 021278 2 000 PIN RETAINING 1 4 OD X 2 L 042306 2 103 PLUG Q D LIQ 1 8 MPT 022134 2 103 POPPET RUB...

Страница 60: ...4 AND UP VALVE SOLENOID 7 32 ORF X 1 4 FP 047496 27 103 S N K7033293 PRIOR VARISTOR A 280VAC NEW X34664 2 000 FOR 053732 27 RELAY J9114884 UP 148 WIRE A 18 GRN YEL 5 X27403 2 103 WIRE A PRESSURE LONG X32663 2 103 FOR X51985 PRESSURE SWITCH DESCRIPTION PART NUMBER 8752 QTY 8756 QTY WARR CLASS REMARKS PARTS UPDATE WATER COOLED BRACKET FAN 454 455 458 752 022077 1 103 BRACKET FAN MTR 8657 SYRUP 04852...

Страница 61: ...380 415V 50HZ 3N COMPRESSOR AEA0415ZXC AE580JT 048627 40 1 1 512 220 240V 50HZ 1PH 380 415V 50HZ 3PH CAPACITOR RUN 25UF 370VAC 023739 1 103 CAPACITOR START 161 193UF 25 031790 1 103 RELAY START COMPRESSOR 038146 1 103 COMPRESSOR L63A113DBEA 048259 58 1 1 512 220 240V 50HZ 1PH 380 415V 50HZ 3PH COMPRESSOR L63A113BBKA 048259 40 1 512 220 240V 50HZ 1PH 380 415V 50HZ 3N CORD 16 3 SPT 3 023907 40 1 000...

Страница 62: ...5V 50HZ 3N PULLEY 2AK30 X 625 6265 010052 1 2 103 RELAY OVRLD 1PHASE 6 3 10 066843 27K 1 220 240V 50HZ 1PH RELAY OVRLD 3PHASE 2 5 4 066843 33H 1 380 415V 50HZ 3N RELAY START COMPRESSOR 038146 1 1 103 SPRING COMP 970X 115X2 00 025707 2 103 SPRING COMP 970X 113X1 5 032967 4 103 STARTER 3 PHASE 2 0 TO 3 041950 33H 2 103 STARTER 3 PHASE 2 5 TO 4 AMP 066794 33H 2 103 380 415V 50HZ 3N 4WIRE VALVE A CHEC...

Страница 63: ...Model 8752P 062336 27 Rev 11 09 ...

Страница 64: ...Model 8752P 052127 27 Rev 5 04 Units built before 11 15 04 ...

Страница 65: ...Model 8752P 062336 33 Rev 11 09 ...

Страница 66: ...Model 8752P 052127 33 Rev 5 04 Units built before 11 15 04 ...

Страница 67: ...Model 8756P 062348 27 Rev 11 09 ...

Страница 68: ...Model 8756P 051900 27 Rev 5 04 Units built before 11 15 04 ...

Страница 69: ...Model 8756P 062348 33 Rev 11 09 ...

Страница 70: ...Model 8756P 051900 33 Rev 5 04 Units built before 11 15 04 ...

Отзывы: