3
Models 8752 & 8756 with Horizon
®
Pump
To the Installer
Beater Rotation
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
Note: The following
procedures
must
be
performed by an authorized Taylor service
technician.
To correct the rotation on a three--phase unit,
interchange any two incoming power supply lines at
freezer main terminal block only.
To correct rotation on a single--phase unit, change the
leads inside the beater motor. (Follow the diagram
printed on the motor.)
Electrical connections are made directly to the
terminal block provided in the splice box which is
mounted on the base pan on the right side of the
freezer for the Model 8752 and located in the splice
boxes which are mounted mid--level on the frame
channel on the right and left sides for the Model 8756.
Refrigerant
In consideration of our environment, Taylor
proudly uses only earth friendly HFC refrigerants. The
HFC refrigerant used in this unit is R404A. This
refrigerant is generally considered non-toxic and
non-flammable, with an Ozone Depleting Potential
(ODP) of zero (0).
However, any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe, apply
ice packs and contact a physician immediately.
Taylor reminds technicians to be cautious of
government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
factory Service Department.
WARNING: R404A refrigerant used in
conjunction with polyolester oils is extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
Содержание Horizon 8752
Страница 1: ...Models 8752 8756 Horizon Pump Soft Serve Freezers Operating Instructions 028752HPM 11 17 09 ...
Страница 14: ...10 Models 8752 8756 with Horizon Pump Operator Parts Identification Model 8756 Figure 3 ...
Страница 63: ...Model 8752P 062336 27 Rev 11 09 ...
Страница 64: ...Model 8752P 052127 27 Rev 5 04 Units built before 11 15 04 ...
Страница 65: ...Model 8752P 062336 33 Rev 11 09 ...
Страница 66: ...Model 8752P 052127 33 Rev 5 04 Units built before 11 15 04 ...
Страница 67: ...Model 8756P 062348 27 Rev 11 09 ...
Страница 68: ...Model 8756P 051900 27 Rev 5 04 Units built before 11 15 04 ...
Страница 69: ...Model 8756P 062348 33 Rev 11 09 ...
Страница 70: ...Model 8756P 051900 33 Rev 5 04 Units built before 11 15 04 ...