25
Models 8752 & 8756 with Horizon
®
Pump
Operating Procedures
Step 13
Insert the parts assembled in Step 12 into the valve
outlet fitting.
Figure 37
Step 14
Slide the pressure relief valve onto the main pump
assembly.
Figure 38
Step 15
Secure the pressure relief assembly by installing the
retaining pin into the rear retaining pin plate.
Figure 39
Note: The assembled parts must align with the
matching hole in the mounting plate.
Step 16
Attach one end of the flare line to the pressure relief
valve outlet fitting of the Horizon
®
pump. Attach the
other end to the mix feed tube.
Figure 40
Содержание Horizon 8752
Страница 1: ...Models 8752 8756 Horizon Pump Soft Serve Freezers Operating Instructions 028752HPM 11 17 09 ...
Страница 14: ...10 Models 8752 8756 with Horizon Pump Operator Parts Identification Model 8756 Figure 3 ...
Страница 63: ...Model 8752P 062336 27 Rev 11 09 ...
Страница 64: ...Model 8752P 052127 27 Rev 5 04 Units built before 11 15 04 ...
Страница 65: ...Model 8752P 062336 33 Rev 11 09 ...
Страница 66: ...Model 8752P 052127 33 Rev 5 04 Units built before 11 15 04 ...
Страница 67: ...Model 8756P 062348 27 Rev 11 09 ...
Страница 68: ...Model 8756P 051900 27 Rev 5 04 Units built before 11 15 04 ...
Страница 69: ...Model 8756P 062348 33 Rev 11 09 ...
Страница 70: ...Model 8756P 051900 33 Rev 5 04 Units built before 11 15 04 ...