68
Troubleshooting
Model C602
Shake Dispensing Mechanism Troubleshooting
(Cont’d.)
PROBLEM
CAUSE
REMEDY
4. Draw valve does not fully open
(long draw time).
a. The solenoid bumper screw is
loose.
a. Align the actuator place and
secure the bumper screw to the
solenoid plunger.
b. The draw solenoid is adjusted too
high.
b. Adjust the draw solenoid to the
proper height. (See page 55.)
5. Draw valve will not close.
a. The freezer door is improperly
installed.
a. Re-install the freezer door. Tighten
the hand screws in a criss-cross
pattern.
b. Improper lubrication of draw valve.
b. Lubricate according to instructions
in the Operator’s Manual.
c. Improper o-rings installed on the
draw valve.
c. Install the correct o-rings - part no.
020571-1 (F treated)
d. The dispensing mechanism is out
of alignment.
d. Re-align the dispensing
mechanism. (See page 54.)
e. The draw valve is binding in the
freezer door.
e. Replace the defective component.
f. The solenoid plunger is binding in
the coil body.
f. Replace the solenoid.
Содержание C602
Страница 1: ...Model C602 Combination Shake Soft Serve Freezer Service Manual 057888 S 4 6 04...
Страница 12: ...9 Model C602 Systems Controls and Operations Refrigeration System Schematic Figure 2...
Страница 42: ...39 Model C602 Systems Controls and Operations Glycol Path Rear View Figure 83...
Страница 46: ...43 Model C602 Systems Controls and Operations Control Overview Figure 86...
Страница 75: ...72 Troubleshooting Model C602 Notes...
Страница 78: ...75 Model C602 Parts Notes...
Страница 79: ...76 Parts Model C602 Main Exploded View Figure 102...
Страница 87: ...84 Parts Model C602 Control Assembly X55966 33 Figure 108...
Страница 90: ...87 Model C602 Parts Torque Coupling Assembly X54722...
Страница 113: ...Model C602 059480 33 Rev 4 04...
Страница 114: ...Model C602 059480 58 Rev 4 04...