28
Systems, Controls and Operations
Model C602
Soft Serve Viscosity Setting (Right):
Enter the Viscosity option and select the AUTO
symbol
to move the cursor up to the right side
viscosity setting and select the CALIBRATION
symbol
. (See Figure 60.)
VISCOSITY SETTING
RIGHT =
2.8 AMPS
CURRENT =
0.0
Figure 60
Select the AUTO symbol
to increase the viscosity
setting or the OPTIONAL FLAVOR symbol
to
decrease the setting. Select the CALIBRATION
symbol
to save the setting and return to the
screen to the Viscosity Setting menu.
Soft serve viscosity is measured by monitoring the
amperage load of the beater motor. While the beater
motor is on, the viscosity or amperage is indicated
on the display. When the beater motor is off, this
value is zero.
COMPRESSOR CYCLE TIME
The COMPRESSOR CYCLE TIME option allows the
service technician to set the time that the
compressor will cycle on in the AUTO mode when
product is not dispensed from the machine.
Compressor Cycle Times range from 5 – 15 minutes
for shake and soft serve applications and is
adjustable in one-minute intervals. Use the AUTO
symbol
or the OPTIONAL FLAVOR symbol
to
adjust the setting. The recommended cycle times
are 5 minutes for shake and 10 minutes for soft
serve.
The Left Compressor Cycle Time is displayed first.
(See Figure 61.)
COMP CYCLE TIME
L CYCLE TIME : 5 MIN
Figure 61
Advance to the next screen for the right side setting
or return to the service menu by selecting the
CALIBRATION symbol
.(See Figure 62.)
COMP CYCLE TIME
R CYCLE TIME : 10 MIN
Figure 62
COMPRESSOR ON DELAY
The COMPRESSOR ON DELAY allows the service
technician to adjust the time the compressor will
delay starting when the unit is in the AUTO mode.
The range for the delay time is 2 seconds to 10
seconds and is adjustable in one-second intervals.
Use the AUTO symbol
or the OPTIONAL
FLAVOR symbol
to adjust the setting. The
recommended setting is 5 seconds for shake and 2
seconds for soft serve applications.
The Left Compressor On delay screen is displayed
first (See Figure 63.)
COMP ON DELAY
LEFT : 5 SECONDS
Figure 63
Advance to the next screen for the right side setting
or return to the service menu by selecting the
CALIBRATION symbol
. (See Figure 64.)
COMP ON DELAY
RIGHT : 2 SECONDS
Figure 64
Содержание C602
Страница 1: ...Model C602 Combination Shake Soft Serve Freezer Service Manual 057888 S 4 6 04...
Страница 12: ...9 Model C602 Systems Controls and Operations Refrigeration System Schematic Figure 2...
Страница 42: ...39 Model C602 Systems Controls and Operations Glycol Path Rear View Figure 83...
Страница 46: ...43 Model C602 Systems Controls and Operations Control Overview Figure 86...
Страница 75: ...72 Troubleshooting Model C602 Notes...
Страница 78: ...75 Model C602 Parts Notes...
Страница 79: ...76 Parts Model C602 Main Exploded View Figure 102...
Страница 87: ...84 Parts Model C602 Control Assembly X55966 33 Figure 108...
Страница 90: ...87 Model C602 Parts Torque Coupling Assembly X54722...
Страница 113: ...Model C602 059480 33 Rev 4 04...
Страница 114: ...Model C602 059480 58 Rev 4 04...