background image

Transmission Collision

Signals from other household devices, such as doorbells, home security systems and entry 
controls, may interfere. This is normal and does not affect the general performance of this 
product. The transmission will resume once the interference recedes.

Note:

 This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio communications. However, 
there is no guarantee that interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:

--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.

Modifications not authorized by the manufacturer may void users authority to operate this 
device.

FCC ID: VVG53631638TX

Problem Solving
1.

 If the LCD readout on the base unit is faint, replace the batteries.

2.

 If outdoor temperature does not display on the base unit:

a)

 Remove and reinstall all batteries; 

b)

 Use fresh batteries;

c)

 Place the rain collection cup sensor closer to the base unit;

d)

 Position the base and rain cup sensor so that the transmission path is free of any   

     obstacles, such as buildings, trees, etc. Try to have no more than 2 or 3 walls 

between 

  

     the units. 

3. 

If synchronization is lost between the base unit and remote sensors:

a)

 The base unit displays “

--.-C

” or “

---.in

”.

b)

 Press “

RE-SYNC

 

on the base unit. 

The base unit will search for the rain cup sensor signal for 3 minutes. If the outdoor 
temperature does not display after 3 minutes, press “

RE-SYNC

” again. If attempts to 

synchronize fail, check that there are no physical obstructions between the units that might 
block transmissions, such as sheds or trees. If necessary, shorten the distance between the 
receiver and remote units. Remove all the batteries from the units, wait at least 10 seconds, 
and then install the batteries again. Repeat Set-Up instructions to re-synchronize the units. 

Trouble-Shooting (continued)

8

• Range of temperature measurement:

   

   

• Resolution: 

0.1 degree for temperature

• Transmission frequency: 

433 MHz

• Temperature trends: 

rising, falling or steady

• Minimum/Maximum: 

temperature/rainfall records

• Clock: 

12 or 24 hour

• Low Battery Indicator

• Transmission: 

Max. 100 ft (30m) open area

• Power: 

2 AAA alkaline batteries (not included) for base unit and 2 AAA alkaline 

batteries for rain cup collector (not included)

Base unit (indoor only): 14°F to 158°F (-10°C to 70°C)

Rain collection cup sensor: -4°F to 158°F (-40°C to 70°C)

Specifications

Содержание 2753

Страница 1: ...Instruction Manual Digital Wireless Rain Gauge Thermometer Indoor Outdoor Thermometer with Remote Rain Gauge Leading the Way in Accuracy 2753 Required Screw Driver 4 AAA Batteries...

Страница 2: ...recommended in extremely cold or hot locations 4 Replace the battery compartment cover and the screws Make sure the door is securely closed to prevent water leakage Temperature Readings 6 Temperature...

Страница 3: ...nsmission range of the rain cup sensor is 100 feet The effective transmission range is vastly affected by obstacles such as walls sheds trees etc Try various set ups for the best results Shorten the d...

Страница 4: ...DE to enter The hour digits flash Press UP or DOWN to change the hours Press MODE to enter The minute digits flash Press UP or DOWN to change the minutes Press MODE to enter The 12 24 hour clock optio...

Страница 5: ...ading is displayed The reading will reset Otherwise the units will automatically reset at 11 59 pm based on the manual clock setting Your Wireless Rain Gauge will store the rainfall history for Last h...

Страница 6: ...tures have gone up more than 2 degrees in an hour Indicates Falling Temperatures temperatures have gone down more than 2 degrees in an hour Indicates Steady Temperature readings Rainfall History conti...

Страница 7: ...will sound again if the set high low temperature falls back within the high low limit 4 To deactivate the alarm press ALERT until the alert icon disappears ALERT ALERT A with the IN icon indicates the...

Страница 8: ...tdoor temperature does not display on the base unit a Remove and reinstall all batteries b Use fresh batteries c Place the rain collection cup sensor closer to the base unit d Position the base and ra...

Страница 9: ...e only It is not sealed against moisture and could be damaged if used outdoors 2 Do not immerse the base unit in water If you spill liquid on it dry immediately with a soft lint free cloth 3 Though th...

Отзывы: