To the Installer

101111

Electrical Connections

In the United States, this equipment is intended to be

installed in accordance with the National Electrical

Code (NEC), ANSI/NFPA 70-1987. The purpose of the

NEC code is the practical safeguarding of persons and

property from hazards arising from the use of

electricity. This code contains provisions considered

necessary for safety. In all other areas of the world,

equipment should be installed in accordance with the

existing local codes. Please contact your local

authorities.

FOLLOW YOUR LOCAL ELECTRICAL CODES!

Each unit requires one power supply for each data

label on the unit. Check the data label(s) on the freezer

for branch circuit overcurrent protection or fuse, circuit

ampacity, and other electrical specifications. Refer to

the wiring diagram provided inside of the electrical box

for proper power connections.

CAUTION: THIS EQUIPMENT MUST BE

PROPERLY GROUNDED! FAILURE TO DO SO

CAN RESULT IN SEVERE PERSONAL INJURY

FROM ELECTRICAL SHOCK!

This unit is provided with an equipotential

grounding lug that is to be properly attached to the rear

of the frame by the authorized installer. The installation

location is marked by the equipotential bonding

symbol (5021 of IEC 60417-1) on both the removable

panel and the equipment’s frame.

S

Stationary appliances which are not equipped

with a power cord and a plug or another device

to disconnect the appliance from the power

source must have an all-pole disconnecting

device with a contact gap of at least 3 mm

installed in the external installation.

S

Appliances that are permanently connected to

fixed wiring and for which leakage currents

may exceed 10 mA, particularly when

disconnected, not used for long periods, or

during initial installation, shall have protective

devices such as a GFI to protect against the

leakage of current, installed by authorized

personnel to the local codes.

S

Supply cords used with this unit shall be

oil-resistant, sheathed flexible cable, not

lighter than ordinary polychloroprene or other

equivalent synthetic elastomer-sheathed cord

(Code designation 60245 IEC 57) installed

with the proper cord anchorage to relieve

conductors from strain, including twisting, at

the terminals and protect the insulation of the

conductors from abrasion.
If the supply cord is damaged, it must be

replaced by the manufacturer, its service

agent, or similarly qualified person, in order to

avoid a hazard.

Содержание 142

Страница 1: ...OPERATOR S MANUAL Model 142 Soft Serve Freezer Original Operating Instructions 039709 M 3 00 Original Publication Updated 8 3 15...

Страница 2: ...ire Ampacity E 2000 Taylor Company 039709 M Any unauthorized reproduction disclosure or distribution of copies by any person of any portion of this work may be a violation of Copyright Law of the Unit...

Страница 3: ...Refrigerant 3 Section 2 To the Operator 4 Section 3 Safety 5 Section 4 Operator Parts Identification 7 Section 5 Important To the Operator 8 Symbol Definitions 8 Power Switch 8 Indicator Light MIX LOW...

Страница 4: ...n this manual is subject to change without notice Note Only instructions originating from the factory or its authorized translation representative s are considered to be the original set of instructio...

Страница 5: ...ormance or damage to the equipment Note All repairs must be performed by an authorized Taylor Service Technician This unit has many sharp edges that can cause severe injuries Site Preparation Review t...

Страница 6: ...e frame by the authorized installer The installation location is marked by the equipotential bonding symbol 5021 of IEC 60417 1 on both the removable panel and the equipment s frame S Stationary appli...

Страница 7: ...it is properly grounded before applying power FOLLOW YOUR LOCAL ELECTRICAL CODES Refrigerant In consideration of our environment Taylor uses only earth friendly HFC refrigerants The HFC refrigerant us...

Страница 8: ...in effect after August 13 2005 Therefore it must be collected separately after its use is completed and cannot be disposed as unsorted municipal waste The user is responsible for returning the product...

Страница 9: ...inse the freezer Failure to follow these instructions may result in serious electrical shock S DO NOT operate the freezer unless it is properly grounded S DO NOT operate the freezer with larger fuses...

Страница 10: ...safety and hygiene are concerned Cleaning and sanitizing schedules are governed by your state or local regulatory agencies and must be followed accordingly Please refer to the cleaning section of this...

Страница 11: ...PLASTIC 039444 5 PAN A WHITE FRONT DRIP X43474 6 SEAL U CUP 080534 7 BEATER A X24689 8 BEARING FRONT 023262 9 O RING 2 3 4 OD X 139W 019998 ITEM DESCRIPTION PART NO 10 BEARING GUIDE 014496 11 DOOR A P...

Страница 12: ...e operator switches ON AUTO OFF WASH Power Switch The center position is the OFF position The left position is WASH which activates the beater motor only The right position is the AUTO position which...

Страница 13: ...e toggle switch to the AUTO position Temperature Adjustments Temperature adjustments should be performed only by an authorized Taylor Service Representative Feed Tube The feed tube meters a combinatio...

Страница 14: ...t to the starting point in our instructions turn to page 17 Disassembly and start there Assembly Note Use an approved food grade lubricant example Taylor Lube when lubricating parts Step 1 Lubricate t...

Страница 15: ...eater assembly The white guide bearing must fit securely in the hole of the drive shaft Step 6 Finger tighten the handscrews making sure they are tightened equally and that the door is snug Do not ove...

Страница 16: ...may be aligned with the left or the right cross hole The draw valve handle will be placed through the opposite cross hole of the valve lifter arm Figure 13 Slide the o ring into the groove on the draw...

Страница 17: ...zing Step 1 Prepare a pail of an approved 100 PPM sanitizing solu tion examples 2 1 2 gal 9 5 liters of Kay 5R or 2 gal 7 6 liters of Stera SheenR USE WARM WA TER AND FOLLOW THE MANUFACTURER S SPE CIF...

Страница 18: ...r five minutes Step 5 Place an empty pail beneath the door spout and open the draw valve Draw off all the sanitizing solution When the sanitizer stops flowing from the door spout close the draw valve...

Страница 19: ...lowing from the door spout close the draw valve Note Use only fresh mix when priming the freezer Figure 24 Step 2 When the mix has stopped bubbling down into the freezing cylinder install the feed tub...

Страница 20: ...The button will light indicating that the unit is operating as a refrigerator for product in the hopper and freezing cylinder Step 3 To remove the unit from the STANDBY mode place the power switch in...

Страница 21: ...e rinse water stops flowing from the door spout close the draw valve and place the toggle switch in the OFF position Repeat this procedure until the rinse water being drawn from the freezing cylinder...

Страница 22: ...out of its groove With the other hand push the top of the o ring forward and it will roll out of the groove and can be easily removed If there is more than one o ring to be removed always remove the r...

Страница 23: ...owing day DO NOT prime the machine with rerun When using rerun skim off the foam and discard then mix the rerun with fresh mix in a ratio of 50 50 during the day s operation j 6 On a designated day of...

Страница 24: ...t the freezer from the main power source to prevent possible electrical damage Your local Taylor Distributor can perform this service for you Wrap detachable parts of the freezer such as beater blades...

Страница 25: ...ce fuse f Freezer door was assembled incorrectly f See Operating Procedures for proper installation 10 g Product is being drawn off far in excess of freezer s capacity g Stop drawing product and allow...

Страница 26: ...l bearing b Contact service technician c Incorrect lubricant c Use food grade lubricant example Taylor Lube 10 d Inadequate lubrication of beater drive shaft d Lubricate properly 10 7 Draw valve leaki...

Страница 27: ...ACED Beater Drive Shaft Cup Seal X 1 Freezer Door O Ring X 1 Freezer Door Front Bearing X 1 Freezer Door Guide Bearing X 1 Draw Valve O Ring X 2 Draw Valve Handle O Ring X 1 Black Bristle Brush 1 x 2...

Страница 28: ...valve Five 5 years Beater motors Two 2 years Beater drive gear Two 2 years Printed circuit boards and Softech controls beginning with serial number H8024200 Two 2 years Parts not otherwise listed in...

Страница 29: ...n whatsoever 12 Damages resulting from the use of any refrigerant other than that specified on the Product s data label will void this limited warranty 13 Any cost to replace refill or dispose of refr...

Страница 30: ...s Twelve 12 months Class 000 Parts No warranty Taylor Part 072454 Motor 24VDC C832 C842 Four 4 years LIMITED WARRANTY CONDITIONS 1 If the date of original installation of the Part cannot be otherwise...

Страница 31: ...work promptly upon arrival 9 Failure damage or repairs due to faulty installation misapplication abuse no or improper servicing unauthorized alteration or improper operation or use as indicated in the...

Страница 32: ...S INCLUDING CLAIMS FOR LOST SALES LOST PROFITS PRODUCT LOSS PROPERTY DAMAGES OR SERVICE EXPENSES ARE EXPRESSLY EXCLUDED THE EXPRESS WARRANTIES MADE IN THIS LIMITED WARRANTY MAY NOT BE ALTERED ENLARGED...

Отзывы: