Taylor-Wharton M2000 Скачать руководство пользователя страница 4

MB2000/3000/5000 OPERATING AND MAINTENANCE MANUAL

 

  TAYLOR-WHARTON (BEIJING) CRYOGENIC EQUIPMENT CO., LTD.

                                 

 

SAFETY PRECAUTIONS FOR LIQUID OXYGEN 

 

Oxygen is a colorless, odorless, and tasteless gas that can be condensed into a liquid at the low 
temperature of -183

(297

degrees below zero Fahrenheit) under normal atmospheric pressure. 

Approximately one-fifth of normal air is oxygen. As a liquid, oxygen is pale blue in color. Oxygen is 
non-flammable but vigorously accelerates the burning of combustible materials.   

Keep Combustibles Away from Oxygen and Eliminate Ignition Sources 

 

Many substances, which do not normally burn in air, require only a slight spark or moderate heat to set 
them aflame in the presence of concentrated oxygen. Other substances, which are only moderately 
combustible in air, can burn violently when a high percentage of oxygen is present.   

Do not permit smoking or open flame in any area where liquid oxygen is stored, handled, or used. Keep 
all organic materials and other flammable substances away from possible contact with liquid oxygen. 
Some of the materials that can react violently with oxygen are oil, grease, kerosene, cloth, wood, paint, 
and dirt, which contains oil or grease. Under certain conditions flammable materials, which have become 
permeated with liquid oxygen, are impact sensitive and can detonate if subjected to shock.   

Keep Area and Exterior Surfaces Clean to Prevent Ignition 

 

As normal industrial soot and dirt can constitute a combustion hazard, all equipment surfaces must be 
kept very clean. Do not place oxygen equipment on asphalt surfaces, or allow grease or oil deposits to 
remain on benches or concrete surfaces in the vicinity of the oxygen equipment. Use cleaning agents, 
which will not leave organic deposits on the cleaned surfaces. Equipment to be used in contact with liquid 
oxygen should be handled oLI1y with clean gloves or hands washed clean of oil.   

Maintain Adequate Ventilation 

 

Enclosed areas containing oxygen equipment should be ventilated to prevent accumulations of oxygen 
and thereby minimize combustion hazards.   

Extreme Cold - Cover Eyes and Exposed Skin 

 

Accidental contact of liquid oxygen or cold issuing gas with the skin or eyes may cause a freezing injury 
similar to frostbite. Handle the liquid so that it won't splash or spill. Protect your eyes and cover the skin 
where the possibility of contact with the liquid, cold pipes and cold equipment, or the cold gas exists. 
Safety goggles or a face shield should be worn if liquid ejection or splashing may occur or cold gas may 
issue forcefully from equipment. Clean, insulated gloves that can be easily removed and long sleeves are 
recommended for arm protection. Cuffless trousers should be worn outside boots or over the shoes to 
shed spilled liquid. If clothing should be splashed with liquid oxygen or otherwise saturated with the gas, 
air out the clothing immediately, removing it if possible.   

Such clothing will be highly flammable and easily ignited while the concentrated oxygen remains, and 

should not be considered safe for at least 30 minutes.   

Replacement Parts Must be Suitable for Oxygen Service 

 

Many materials, especially some non-metallic gaskets and seals, constitute a combustion hazard when in 
oxygen service, although they may be acceptable for use with other cryogenic liquids. Make no 
substitutions for recommended spare parts. Also, be sure all replacement parts are thoroughly "Cleaned 
For Oxygen Service" in accordance with Compressed Gas Association (CGA) Pamphlet G-4.1 "Cleaning 
for Oxygen Service" or equivalent industrial cleaning specifications.   

 

Observe Safety Codes When Locating Oxygen Equipment 

 

Before locating oxygen equipment, become thoroughly familiar with National Fire Protection Association 

Содержание M2000

Страница 1: ...NIC LIQUIFIED GAS TANK M2000 M3000 M5000 V2000 V3000 V5000 MB TANK VESSEL ON SKID FOR AIR LIQUIDE Taylor Wharton Beijing Cryogenic Equipment Co Ltd East End of Ping An Street Xianghe Economic Developm...

Страница 2: ...ON HANDLING 10 INSTALLATION CHECKS 10 OPERATION PURGE PROCEDURE 12 FILLING A WARM TANK 13 FILLING A COLD TANK 13 NORMAL OPERATION 14 TAKING A TANK OUT OF SERVICE 14 MAINTENANCE GENERAL 15 LEAK TESTING...

Страница 3: ...MAINTENANCE PROCEDURES READ AND FOLLOW ALL SAFETY PRECAUTIONS IN THIS SECTION AND IN REFERENCE PUBLICATIONS FAILURE TO OBSERVE ALL SAFETY PRECAUTIONS CAN RESULT IN PROPERTY DAMAGE PERSONAL INJURY OR P...

Страница 4: ...surfaces Equipment to be used in contact with liquid oxygen should be handled oLI1y with clean gloves or hands washed clean of oil Maintain Adequate Ventilation Enclosed areas containing oxygen equipm...

Страница 5: ...ygen systems on industrial and institutional consumer premises CAUTION When installing field fabricated piping make certain a suitable safety valve is installed in each section of piping between shut...

Страница 6: ...nd non flammable it can cause asphyxiation in a confined area without adequate ventilation Any atmosphere which does not contain enough oxygen for breathing can cause dizziness unconsciousness or even...

Страница 7: ...000 model cryogenic storage tanks These tanks are suitable for the storage and delivery of liquid oxygen nitrogen or argon at a maximum allowable working pressure of 1 6 MPa 232 psig for M series MB t...

Страница 8: ...RIES TANK MODEL Gross Volume m 3 Net Volume m3 Height m Dime nsions mm Weight Ton Full Weight Ton STATIC EVAPORATION LIN volume day MAWP MPa LOX LIN LAr M5000 4 99 4 49 3 2000 2 8 7 93 6 43 9 06 1 1 6...

Страница 9: ...MB2000 3000 5000 OPERATING AND MAINTENANCE MANUAL TAYLOR WHARTON BEIJING CRYOGENIC EQUIPMENT CO LTD 8...

Страница 10: ...SSURE BUILD UP VALVE HV3 It lets the liquid of the container flow to the build up pressure line when it is opened PRESSURE REGULATOR PCV1 When tank pressure decreases to PCV1 set point it opens and li...

Страница 11: ...stomer s responsibility The MB tank with pallet for equipment to hand or transit expediently no especial demand for the toft to use temporarily advise build one toft for fixation long time and refer t...

Страница 12: ...MB2000 3000 5000 OPERATING AND MAINTENANCE MANUAL TAYLOR WHARTON BEIJING CRYOGENIC EQUIPMENT CO LTD 11...

Страница 13: ...must be gradual enough to allow the liquid to vaporize in the bottom fill line and pressure building coil so the pressure builds up in the inner vessel Momentarily open top fill valve HV2 to flood the...

Страница 14: ...ts from tank trycock valve close supply source valve to stop fill Close tank trycock valve 8 When residual liquid in the fill hose vaporizes close tank top fill valve CAUTION To avoid injury do not to...

Страница 15: ...A TANK OUT OF SERVICE Schedule shut down operation to coincide with low liquid level in the tank If a large quantity of liquid is in the tank drain it into a trailer for use elsewhere or for disposal...

Страница 16: ...eaned for in conformance with CGA Pamphlet G 4 1 Cleaning Equipment for Oxygen Service or other equivalent standard If parts are purchased cleaned for oxygen service they should be suitably packaged t...

Страница 17: ...be set so that tank pressure is held about 0 035MPa above the desired delivery pressure the economizer pressure regulator PCV2 should be set at least 0 07MPa 10 psig above the setting of the pressure...

Страница 18: ...row away type PRESSURE AND LIQUID LEVEL GAUGES The major cause of malfunctioning tank pressure gauge inner vessel or liquid level gauge is an open equalization valve or leakage in the gauge lines Refe...

Страница 19: ...the vacuum probe into vacuum probe isolation valve using two wrenches Do not over tighten 5 Install a new vinyl cover over the vacuum probe connector NOTE If corrosion of the vacuum probe is a proble...

Страница 20: ...wn connection and vacuum bursting disc f All liquid and gas phase lines exit points through vacuum jacket g Any area of the vacuum jacket that might have been exposed to cryogenic liquid spray or temp...

Страница 21: ...ck d Liquid Level Gauge needle not zero adjusted e Gauge line reversed f Liquid Level Gauge damaged or faulty g Plugged gauge lines Test and repair leaks Close by pass valve Tap Liquid Level Gauge sli...

Отзывы: