3 & 5 Flashes - Tripped Circuit Breaker
When your alarm has 3 and 5 flashes, this means you have a tripped circuit
breaker. This can be caused by issues with the aerator or other electrical
components. If this happens refer to the diagram on page 13 and reset the
breaker.
Resetting the Breaker
1.
Remove the 4 screws on the blower box.
2.
Underneath the double power point locate the button as shown
below.
3.
Turn off both switches (1 = Pump & 2 = Blower)
4.
Push in the reset button and wait 10 seconds.
5.
Switch on switch 1 and wait 10 seconds.
6.
Switch on switch 2 and wait 10 seconds.
7.
If the circuit breaker “Trips” when either one of the switches are
turned on, this would indicate there is a problem with the
pump or blower. Leave the faulty switch in the off position
and notify your service agent immediatley.
8.
If the system doesn’t alarm, monitor for the next 3 days.
9.
If the system continues to alarm, call your local wastewater sepcialist.
Normal Operation
RESET BUTTON
Circuit Breaker
Activated / “Tripped”
1
2
3