The Power Supply
The power outlets for the ECO Controller for your system are located inside
the Blower Box. Each switch must be in the ON position at all times. If any or
all switches are OFF, the treatment process and alarms may not function.
The single GPO is for the 240V – 12V power supply for your controller and the
double GPO is for your Pump and Blower. The double GPO contains a 7amp
breaker underneath the GPO, which will activate in the case of a fault with the
pump and/or blower. If the breaker is activated it will trigger the associated
alarm on the Controller. You can reset the Breaker by pushing in the reset
button (see page 15 for full instructions). If the breaker is activated again,
please contact your Service Agent to rectify the issue.
Normal Operation
RESET BUTTON
Circuit Breaker
Activated / “Tripped”
Optional Extra
A 12volt In House Alarm Panel is
available as an optional extra to the
system. If required, the panel can be
fitted during the installation of the
system. The In House Alarm Panel
is connected to the same circuit as
the Alarm, situated on the system,
and works in tandem with the same
functions listed above. To mute the In
House Alarm, press the red button, this
will silence the alarm. The alarm at the
system will still function, and needs to
be muted separately. The LED light on
the In House Alarm panel will continue
to flash until the fault is rectified.
FIGURE (2)