14. Position the cover plate over the valve housing and fix in place with the cover plate fixing nut.
Tighten the plate to the wall with the tool provided making sure not to scratch the cover plate. Make
sure the cover plate is level and that the button is in line with those on the valve. The cover plate is fitted
with an integrated foam seal - it is not necessary to use silicone sealant.
You are now ready to set the maximum temperature of the valve.
15. With all outlet buttons checked for smooth operation, using a thermometer, test the temperature
of the water from the outlets. Rotate the cartridge spindle anti-clockwise to increase the temperature
and clockwise to reduce the temperature until the water from the outlet reaches the maximum
recommended temperature of 44ºC. Leave the cartridge spindle in this position.
Figure 18
Figure 19