Fixing Nut
Button Spring
Button
Remove the brass fixing nut from the back of the cover plate, as shown above. This will allow the etched
button and spring to be removed. Rotate the button 90 degrees and reassemble to the cover plate.
(Figure 16). There are four slots which ensure the button is located correctly. With the spring assembled
inside the channel on the back of the button, reassemble the brass fixing nut.
NOTE: For horizontal installations, the cover plate can be fitted immediately - proceed to Step 14.
For vertical installation the control button and temperature stop need to be removed and rotated
so that they are in the correct orientation. To do so, follow the below instructions:
The temperature stop ring is installed onto the temperature cartridge fixing nut on the valve. This
prevents the maximum temperature from being exceeded when in use. For vertical installations the
temperature stop ring needs to be removed and rotated 90 degrees as shown (Figure 17)
Figure 16
Temperature
Stop Ring
Figure 17