background image

20

RB10.5

Step 5:

 Mounting the handles and backrest

1.   Insert the backrest (119) into the main frame (1) and secure with three screws (15), three 

washers (16), and three spring washers (9).

2.  Connect the cables (37L & 18) and the cables (37R & 18) (see fig. 4-1).
3.  Attach the handles with the hand pulse sensors (36) to the main frame (1) with two screws (41) 

and two curved washers (8). 

4.  Place the bottle holders (20) in the holders of the handles with the hand pulse sensors (36).
5.  Attach the front handlebar (72) to the front post (17) with two screws (41) and two curved 

washers (8). 

6.  Place the cover (42) on the front handlebar (72) on the screw connection.

Содержание ergometer RB10.5 PRO

Страница 1: ...TFRB105 02 05 max 180 kg 60 Min C M 72 kg Assembly and Operating Instructions Recumbent Bike RB10 5 Pro L 170 W 75 H 122 Art No TF RB105 2...

Страница 2: ...2 RB10 5...

Страница 3: ...r Stra e 55 24837 Schleswig Germany Management Christian Grau Sebastian Campmann Dr Bernhard Schenkel No HRB 1000 SL Local Court Flensburg European VAT Number DE813211547 Disclaimer 2011 Taurus is a r...

Страница 4: ...ollow the instructions and that all parts are securely in place If required read through the instructions again to correct any mistakes Please pay close attention to the safety and maintenance instruc...

Страница 5: ...uick Start program 27 3 5 2 Target programs 27 3 6 PROGRAM Profile programs 28 3 7 USER User defined program 30 3 8 H R C Heart rate controlled programs 31 3 9 WATT Watt program 32 3 10 RECOVERY Recov...

Страница 6: ...6 RB10 5 7 RECOMMENDED ACCESSORIES 40 8 ORDERING SPARE PARTS 41 8 1 Serial Number and Model Name 41 8 2 Parts List 42 8 3 Exploded Drawing 46 9 WARRANTY 47 10 CONTACT 49...

Страница 7: ...programme 10 350 W Min and max Watt at 60 RPM 20 300 W Min and max Watt at 100 RPM 73 569 W User profiles 4 Programs in total 23 Quick start program 1 Target programs 4 Pre set programs 12 User define...

Страница 8: ...cess to the equipment Persons with disabilities must have a medical license and must be under strict observation when using the equipment The equipment is strictly for use by one person at a time If y...

Страница 9: ...ug is damaged or defective contact your contract partner Until repair the equipment must not be used ATTENTION The equipment requires a mains connection of 220 230 V with 50 Hz mains voltage The equip...

Страница 10: ...sides of the equipment The set up and mounting surface of the equipment should be flat loadable and solid ATTENTION The device may only be used in one building in sufficiently tempered and dry rooms...

Страница 11: ...Do not open the packaging when it is lying on its side Ensure to have sufficient room for movement in each direction during assembly The assembly of the equipment must be carried out by at least two...

Страница 12: ...ck whether all parts and tools belonging to the device are included in the scope of delivery and whether damage has occurred In the event of complaints the contractual partner must be contacted direct...

Страница 13: ...CS 9 D15 4 D8 2 2T 8PCS mm 16 D16 D8 5 1 2T 8PCS 7A M8 1 25 110L 4PCS 15 M8 1 25 15L 4PCS 16 D16 D8 5 1 2T 4PCS 9 D15 4 D8 2 2T 4PCS 42 97 2 75 42 1PC 41 M8 1 25 50L 4PCS 8 D22 D8 5 1 5T 4PCS 15 M8 1...

Страница 14: ...ure 1 1 CAUTION For the next step the equipment must be lifted on one side Use the help of another person to do this For additional stabilization you can use the polystyrene from the packaging materia...

Страница 15: ...15 7 9 16 7A 2 9 16 7A 7 1 2 9 16 7A 7 1 9 7 16 7A 4 9 7 16 7A 4 M8x1 25x70L D16xD8 5x1 2T x4 x8 x8 D15 4xD8 2x2T 13 15 M8x1 25x110L x4 1 3 1 1 1 2 1 4 15...

Страница 16: ...bolts 15 four spring washers 9 and four flat washers 16 5 Slide the cover 11 down again see fig 2 4 Step 3 Alignment of the feet If the floor is uneven you can stabilise the training equipment by turn...

Страница 17: ...17 11 17 64 65 65 64 9 15 16 11 17 15 9 16 18 14 18 14 1 M8x1 25x15L D16xD8 5x1 2T x4 x4 x4 D15 4xD8 2x2T 13 15 2 1 2 2 2 4 2 3 17...

Страница 18: ...cables 76 64 and the cables 76 14 with one another see fig 3 1 2 Place the console 76 on the front post 17 3 Attach the console 76 to the front post 17 with four screws 39 see fig 3 2 4 Fix the cover...

Страница 19: ...76 39 40 39 64 76 14 76 39 17 76 17 39 40 64 14 1 39 Step 3 M5 12L x8 3 1 3 2 3 3 19...

Страница 20: ...the cables 37R 18 see fig 4 1 3 Attach the handles with the hand pulse sensors 36 to the main frame 1 with two screws 41 and two curved washers 8 4 Place the bottle holders 20 in the holders of the h...

Страница 21: ...8 41 72 42 15 9 16 18 37L 37R 18 37L 37R 15 9 16 41 8 1 36 119 20 41 8 Step 4 M8x1 25x15L D16xD8 5x1 2T x3 x3 x3 D15 4xD8 2x2T M8x1 25x50L x4 D22 D8 5 1 5T x4 13 15 4 1 21...

Страница 22: ...a power board otherwise it cannot be guaranteed that the equipment will be supplied with sufficient power Technical errors can result L NOTICE The mains plug should only be used if the battery charge...

Страница 23: ...16 112 69 1 38 39 39 39 5 5 39 51L 48L 51L 48R 51R 51R 39 112 38 16 114 115 Step 5 M5 12L x8 x4 x4 ST4 2 15L x1 D16xD8 5x1 2T M8x1 25x35L 13 15 L R 23...

Страница 24: ...min increments SPEED Display of the current speed max 99 9 DISTANCE Display of the distance covered 0 00 99 99 Set a target distance with the rotary knob 0 00 99 0 in 1km increments CALORIES Display o...

Страница 25: ...tting value or resistance level Setting confirmation BODY FAT Body fat test RECOVERY Heart rate test on your recovery condition RESET Returns you to the previous training mode while making settings or...

Страница 26: ...HT and weight WEIGHT You will proceed onto the main menu In the main menu you can choose from the different programs MANUAL Quick Start and target programs PROGRAM Profile programs USER PROGRAM user d...

Страница 27: ...singular or multiple targets set Training with a singular target value 1 In the main menu select MANUAL and confirm your choice with a single push of the rotary knob 2 Select your target value for ti...

Страница 28: ...ount down and the other values count upwards 4 To pause the program press the START STOP button again 5 To end the program press the RESET button 3 6 PROGRAM Profile programs There are a total of 12 p...

Страница 29: ...P7 P8 P9 P10 P11 P12 P1 P2 P3 P4 P5 P6 29...

Страница 30: ...levels press and hold the rotary knob for 2 seconds The last set level is shown on the display You now have the option to set training time with the rotary knob 4 Using the rotary knob select the tra...

Страница 31: ...main menu select H R C and confirm your choice with a single push of the rotary knob 2 Using the rotary knob select one of the pre set target heart rate programs or TARGET and confirm your choice with...

Страница 32: ...the set Watt value 4 To pause the program press the START STOP button again 5 To end the program press the RESET button 3 10 RECOVERY Recovery function Use the recovery function after a training sess...

Страница 33: ...u not properly grip the hand pulse sensors the display will show the error code E 1 L NOTICE If you wish to prematurley end the body fat analysis and return to the previous program press the BODY FAT...

Страница 34: ...evice tablet or smart phone and start the fitness app Select your fitness equipment Please follow the instructions given in the app You will find the name of your fitness euqipment on a small sticker...

Страница 35: ...n wheels the equipment must be disassembled before transportation 4 2 Transportation Wheels ATTENTION If you want to transport your equipment over particularly sensitive and soft floor coverings such...

Страница 36: ...eless faults or malfunctions may occur Frequently individual parts are responsible for these disturbances an exchange is usually sufficient Please refer to the following overview for the most common e...

Страница 37: ...ror code is shown on the display and normal operation is stopped for your safety E 1 No values were received during the body fat analysis Make sure that during the analysis you hold on to the hand pul...

Страница 38: ...e The video serves to illustrate the maintenance points described in this manual Please note that the video may not be available in your language or with appropriate subtitles If you cannot scan QR co...

Страница 39: ...LA battery for short For proper disposal of the unit the installed SLA battery must first be removed It is located underneath the frame L NOTICE TheTaurus crosstrainer X10 5 Pro is used as an example...

Страница 40: ...use a compatible chest strap as this ensures optimum transmission of the heart rate You may want to buy additional grips or weights for multi gyms Our range of accessories offers the highest quality...

Страница 41: ...have the model name article number serial number exploded drawing and parts list ready The corresponding contact options can be found in chapter 10 of this operating manual L NOTICE The serial number...

Страница 42: ...191 9 172 1 138 4 1 13 Seat post 744S0 3 2200 BA2 1 14 Middle cable for quick button 744S0 6 2543 00 550L 2 15 Bolt 50108 5 0015 F0 M8 1 25 15L 4 16 Flat washer 55108 1 1612 FA D16 D8 5 1 2T 29 17 Ha...

Страница 43: ...e cover for handlebar 734S0 6 3781 B0 97 2 75 42 1 43 Frong protective cover for handlebar 734S0 6 3780 B0 100 77 1 42 1 44 Flat washer 55120 1 2615 NA D26 D21 1 5T 1 45 Crank cover 744S0 6 4524 C0 D1...

Страница 44: ...300L 1 74 Power cable 807S1 6 2596 00 700L 1 75 Connecting cable 841G0 6 3177 00 300L 1 76 Computer 744G1 6 2501 B0 SR 8627 31 1 77 C ring 55517 1 0010 00 S 17 1T 1 78 Waved washer 55117 5 2203 DA D1...

Страница 45: ...1 109 Locking base 73502 6 2219 N1 71 5 20 4T 1 110 Spring 58003 6 1077 N0 D1 5 D10 35L 1 111 Moving wheel 73502 6 3886 B0 D25 D10 11 5 8 112 Bolt 50108 5 0035 F3 M8 1 25 35L 4 113 Square cap 55315 2...

Страница 46: ...124 125 46 RB10 5 8 3 Exploded Drawing...

Страница 47: ...uyer and or any person who received a newly purchased product as a gift from the original buyer Warranty periods The following warranty periods begin on delivery of the fitness equipment Warranty peri...

Страница 48: ...Please make sure that you are able to provide the appropriate receipt when claiming on your warranty So that we can clearly identify the model of your equipment and for the purposes of our quality con...

Страница 49: ...fr Mo Fr 08 00 18 00 Sa 09 00 18 00 PL BE TECHNICAL SUPPORT SERVICE TECHNICAL SUPPORT SERVICE 22 307 43 21 49 4621 42 10 948 info fitshop pl Mo Fr 08 00 18 00 Sa 09 00 18 00 02 732 46 77 49 4621 42 1...

Страница 50: ...s companies and physio practices with professional equipment for endurance and strength training Sport Tiedje offers a wide range of fitness equipment from renowned manufacturers high quality in house...

Страница 51: ...51...

Страница 52: ...TF TF Recumbent Bike RB10 5 Pro...

Отзывы: