16
K892M
11 - 12
AUX 24V AC
24 Vac output for powering safety and/or other devices (photo
-
cells, relays for lighting, etc);
13 - 15
PRESSURE-SENSI-
TIVE EDGE
Pressure-sensitive edge input;
13 = Pressure-sensitive edge; 15 = Common.
If the resistive sensitive edge is not used, do not short circuit ter-
minals 13 and 15. The input is only excluded by means of dip 9;
Note:
if the resistive sensitive edge is used,
to install the
electric resistance provided as shown in enclosed instruc-
tion.
14 - 15
SENSITIVE EDGE/
PHOTOCELLS
Input for pressure-sensitive edge (mechanical edge) or other
safety devices, e.g. photocells (NC contact);
14 = pressure-sensitive edge; 15 = Common;
16 - 17
STOP
Stop push button NC (normally closed) contact. After a stoppage,
the system always starts again with an opening phase and only
after receiving a command from the On button or radio transmit-
ter. 16 = Common; 17 = Stop;
16 - 18
OPEN/CLOSE
Input for open/close push button (normally-open contact): for us
-
age, see the functions of dip switches 2-3;
16 = Common; 18 = Open/close;
19 - 20 - 21
MOTOR 1
Motor (1) output;
19 = Closing phase; 20 = Common; 21 = Opening phase;
22 - 23 - 24
MOTOR 2
Auxiliary motor (2) output;
22 = Closing phase; 23 = Common; 24 = Opening phase;
M5
STOP
OPEN/CLOSE
FCC
FCA
PIN1
Input for STOP push button
PIN2
Input for OPEN/CLOSE push button
PIN3
Common GND
PIN4
Input for closing limit switch FCC
PIN5
Input for opening limit switch FCA
Note: if the card is fitted in replacement of an older model (K595M, K696M, K797M or K898M)
there is no M5 terminal block. In its place is a terminal block with 3 screw units that must be
wired as follows:
25 - 27
FCA
Open limit switch input (Normally Closed contact) FCA;
27= Common;
26 - 27
FCC
Close limit switch input (Normally Closed contact) FCC;
27= Common.
M9
ENCODER
Encoder quick connector
PIN COM
BLUE negative
PIN +5V
BROWN positive
PIN ENC
WHITE signal
NEW K892M FUNCTIONS (software version 3.10)
Board power-up:
On power-up with DIP4 set to ON, the board checks whether the work time is memorised. If this is not
detected, led DL7 flashes quickly, to indicate that the stroke setup procedure needs to be performed.
In all other cases, the first manoeuvre performed by the board is opening, unless already positioned
against one of the limit switches. During this phase, the board does not accept O/C inversion (Open/
Close).
LOGIC ADJUSTMENTS
TRIMMER
TCA
Trimmer for adjusting the pause (5-120 sec), or the time the door remains open with the TCA
is enable. The count begins at the end of the operating time for the opening phase or when
reaching the opening limit switch. It stops when a manual closing command is given and is
temporarily disabled when a stop command is given.
ENGLISH