23
3
CLOSES AGAIN
AFTER THE
PHOTOCELL
On
after the photocell is activated (input 7 - 9), the automation closes automat
-
ically after 5 seconds.
Off
function off.
4
NO REVERSE
On
the automation ignores the closure command during opening and auto-close
time
Off
the automation responds as established by dip switch No. 2.
5
PRE-
FLASHING
On
the pre-flashing function is enabled.
Off
the pre-flashing function is disabled.
6
FOTOTEST
On
the “photocell test” function is enabled.
Off
the “photocell test” function is disabled.
Note: to be used when the photocells are not used.
7
MASTER/
SLAVE
On
enables the MASTER mode in the master/slave configuration (see T-COMM
instructions).
Off
enables the standard operation (single motor) or SLAVE mode in the mas-
ter/slave configuration (see T-COMM instructions).
To carry out the memorization, leave DIP SWITCH 7 on OFF.
8
WITH LIMIT
SWITCHES:
SELECTION
TOWARDS OPENING
On
operation for gate with opening to the right (gearmotor side);
Off
operation for gate with opening to the left (gearmotor side);
WITHOUT LIMIT
SWITCHES:
BACK JUMP
On
once the mechanical stop of the closing maneuver is reached, the automa-
tion makes a slight movement in the opposite direction to avoid jamming
between the rack and the pinion.
Off
function deactivated
To change the position of Dip 8, the power must be disconnected. Once modified, rerun
the SetUp of the stroke
9-10-11
Automation type selection
Dip 9
Dip 10 Dip 11 Automation
Off
Off
Off
T-ONE10B
For gates up to 400 kg
On
Off
Off
T-ONE10B
For gates from 600 to 1000 kg
Off
On
Off
T-ONE8BR (24v)
On
On
Off
MASTER-R (24V Opening speed = Closing speed)
On
On
On
MASTER18QR
On
Off
On
MASTER-R (24V)
Off
On
On
T-ONE8BR (24V Opening speed = Closing speed)
Off
Off
On
CANTILEVER TONE10B (heavy)
IMPORTANT: the type of automation and its parameters are set during the programming
of the stroke ONLY the first time the procedure is carried out (led DL2 flashing red/green
alternately). To change the type it is necessary to perform a “FACTORY RESET” before
starting a new setup procedure.
6. MEMORIZATION PROCEDURE OF THE STROKE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations and check:
- The Input connections: all green DL5, DL6, DL7, DL8 must be on steady.
- The mechanical stops of the automation must be installed and adjusted both in opening and
in closing [see motor instructions].
ENGLISH