![tau K130MA Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/tau/k130ma/k130ma_installation-manual_821512022.webp)
22
21 - 22
AERIAL
Plug-in radio-receiver aerial input , for 433.92 MHz receivers only. (21=
GROUND - 22= SIGNAL)
23 - 24
- 25
ENCODER
Encoder supply output
(23= WHITE signal - 24= BLUE negative - 25=
BROWN positive)
26 - 27
MOTOR
Motor supply output 18/24 V DC max. 200W. (26= POSITIVE - 27= NEGA
-
TIVE)
J2
OPTIONAL
LIMIT SWITCHES
Quick coupling for connection for limit switches
.
Notice: connect/disconnect the limit switches with the control unit
disconnected. It is advisable to wait 10 seconds before powering up
the control unit again.
J3
MEMORY CARD
Quick plug-in for MEMORY CARD connection for transmitters codes.
J4
AUX
Quick coupling for the connection of the
T-WIFI
and
T-CONNECT
devices
J5
ENCODER
Quick plug-in for ENCODER. Blue= 0 Vcc
(- GND)
,
brown= 5 Vcc
(+5V)
, white= ENCODER SIGNAL
(ENC)
;
J6
ENERGY SAVING
MODE
Quick plug-in for ENERGY SAVING MODE activazione. Once activated, at
the end of each manouvre, outputs 11-12, 12-13, 14-15, 16-17 and 16-18
will be switched off.
IMPORTANT:
•
do not power up auxiliary relays o other devices through the 18V DC output (terminals 11
– 12) to avoid malfunctions of the control unit. Use separated power supply / transformers
instead;
•
do not connect switching feeders or similar apparatus close to the automation that may be
a source of disturbance.
5. LOGIC ADJUSTMENTS
Make the logic adjustments.
Note: when any adjusting devices (trimmers or dip-switches) on the control panel are operated,
a complete manoeuvre must be carried out in order for the new settings to take effect.
TRIMMER
V-RAL
adjusts the automation deceleration speed during the final section of the stroke;
Note: When memorizing the stroke, set the TRIMMER RALL fully turned coun-
terclockwise (minimum deceleration speed).
FR.
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the gearmotor
to obstacles diminishes
and therefore the thrust force increases
; vice-versa, by
rotating it counter-clockwise, the sensitivity of the gearmotor to obstacles
increases
and therefore the thrust force diminishes
.
Beyond a certain threshold, the TRIMMER FR inhibits the detection of obstacles.
This is signaled during the maneuvers by 7 orange flashes of the DL2
T.C.A.
Automatic Closing time adjustment: from about 1 to 120 seconds (see dip-switch no. 1);
V-RAL
Dip switch
1
AUTOMATIC
CLOSING
On
when completely open, closure is automatic after the set time on the T.C.A.
trimmer has past.
Off
the closing manoeuvre requires a manual command.
2
2 / 4 STROKE
On
when the automation is operating, a sequence of opening/closing commands
causes the automation to OPEN-CLOSE-OPEN-CLOSE, etc.
Off
in the same conditions, the same sequence of commands causes the auto-
mation to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc . (step-by step function)
(see also dip switch 4).
ENGLISH
Содержание K130MA
Страница 45: ...45 ...