21
GB
INSTALLATION
reset button, high limit safety cut-out
»
Isolate the appliance from the power supply.
»
Undo the screws and remove the bottom cap.
»
Disconnect the connecting cable from the electronic assembly for operation, position X2.
G
1 High limit safety cut-out reset button
16
sPeCifiCatiOn
16.1
dimensions and connections
H
eo 30 el eo 50 el eo 80 el eo 100 el eo 120 el eo 150 el
a10 Appliance
Height
mm
696
951
893
1045
1200
1435
a20 Appliance
Width
mm
380
380
475
475
475
475
a30 Appliance
Depth
mm
392
392
492
492
492
492
b01 Entry electrical
cables
Height
mm
98.5
98.5
78.5
78.5
78.5
78.5
c01 Cold water inlet
Male thread
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
Top clearance mm
20
20
0
0
0
0
Rear clearance mm
80
80
85
85
85
85
c06 DHW outlet
Male thread
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
Top clearance mm
20
20
0
0
0
0
Rear clearance mm
80
80
85
85
85
85
i13
Wall mounting
bracket
Height
mm
445
705
592
735
870
1090
Wall mounting bracket
I
16.2
Wiring diagrams and connections
J
R 560 Ω
1 Anode
2 Water heater
3 Mains terminal
4 Stainless steel heating element
5 No. of heating elements, 2 kW ~ 230 V
6 Additional heating element, 1 kW ~ 230 V
7 High limit safety cut-out
8 Operating mode switch
9 Jumper ECO
10 Reverse control jumper
11 Electronic assembly, control unit
12 Electronic assembly, operation
13 Temperature sensor