background image

4

21

3.3 Configuration with the mixer that controls the floor system
!

For this configuration you set <60>(

ModeMIXER

)=FLOOR

Rys.2C Controller with the 3-way mixing valve that controls the floor system

DM-

blower

TB-

safety sensor of the boiler

T1-

sensor of the boiler temperature

T2-

sensor of the WAW container
temperature

T3-

temperature sensor of the mixer system
(floor)

T4/TP-

room thermostat

T6-

sensor of the flue gas temperature

P1-

CH circulating pump

P2-

pump loading the WAW container

P3-

pump of the mixer

M-

drive of the mixer

4

5

The blower

The CH pump

The controller automatically controls the efficiency of the blower. The applied PID algorithm
enables the operation with modulation of boiler power- the level of generated heat is adjusted to what
is needed-thanks to that the combustion process is uniform (there aren

t any sudden changes of

temperature in the combustion chamber and chimney), is more efficient and it guarantees longer life
of the heating system. By analyzing the tendency of temperature changes the controller modifies its
settings gradually coming up to the balance point.
In case if the boiler temperature is higher than the preset one, the controller turns off the blower and
realizes scavenges. The scavenge parameter is defined by

and

and

.

If boiler temperature exceeds 42 C (

), the CH pump turns on. Below that

temperature the pumps turns off causing a faster heating of the water jacket over the dew point and in
fact extending the life of the boiler.
While loading the WAW container or if the room thermostat operates the CH pump can cyclically run
(restricting the heat flowing in to the CH system). The cyclical operation is based on switching on the
pump for 45secs and then stopping it for 4min (

).

4 C.

<34> TimeSCAVENGE

<33>

BreakSCAVENGE

<35> EfficiencySCAVENGE

<41>T.onPumpCH

<44> TimeStopPumpCH

o

o

!

!

The controller protects the system from freezing, automatically switches on the circulating pump if

the measured temperature is below

The controller realizes an after-season rundown of the pump. The pump turns on for a minute if it

doesn

t run for a week.

Connection cable of the controller may be replaced

only by producer or his authorized service locations

WARRANTY

WARNING !

ANY MODIFICATION OF THE CONTROLLER MADE BY USER CAN BE
THE CAUSE OF SAFETY CONDITIONS DETERIORATION AND CAN

EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES
SUPPLIED

.

Date of sale

Seller's signature and stamp

Zak

ł

ad elektroniczny TATAREK Jerzy Tatarek

50-559 Wroclaw, 75 Swieradowska st

ph. (071) 367-21-67, 373-14-88, fax 373-14-58; tax index number 899-020-21-48;

Bank account : BZ WBK S.A. O/WROC

Ł

AW 6910901522-0000-0000-5201-9335

www.tatarek.com.pl.; E-mail: [email protected]

1.Warranty is valid [24] months from the date of sale.
2.Producer does not take responsibility for any mechanical damages made by user.
3.MAKING REPAIRS OR MODYFYING THE CONTROLLER BY USER IS

FORBIDDEN AND CAUSES WARRANTY CANCELATION

4.Warranty card is valid only with date of sale, seller's signature and stamp
5.Warranty and after-warranty repairs should be done only by producer, damaged
controllers should be sent to producer in order to make all repairs needed.
6.Warranty protection involves the EU
7.Warranty does not exclude, not restrict and not suspend buyer

s rights coming from

the incompatibility of the article with the agreement (Laws Journal No. 141 Pos. 1176)

WARNING!

1. Producer does not take the responsibility for damage
caused by atmospheric discharge
2. and overvoltage in the mains
3. Burnt fuses are not subject to warranty replacement

Register No.. GIOS: E 0002240WZ

Worn out electronic

and electric devices must be transfered to

the utilization collection place, where will

be accepted for free

ARGO-FILM
Recycling Plant No. 6
180 Krakowska st., 52-015 Wroclaw
ph.: 071 794 43 01,

0 515 122 142

Содержание RT-14

Страница 1: ...thermostat 94 C 230V 50Hz Power consumption without load 4W Max connection power 750W Operation conditions 0 50 C humidity10 90 no condensation Housing protection class IP41 Fuse 6 3A 250V P of blower...

Страница 2: ...ILER 45min the temperature doesn t increase then the blower turns off an The given temperatures relate to the situation when the sensor of the flue gas is inactive After connecting the flue gas sensor...

Страница 3: ...r our sole responsibility that the product Controller of the Heating System model RT 14 PN EN 55022 2011 EMC IT devices Characteristics of radioelectric noises Acceptable levels and measurement method...

Страница 4: ...TimeStopPumpCH o o The controller protects the system from freezing automatically switches on the circulating pump if themeasuredtemperatureisbelow The controller realizes an after season rundown of t...

Страница 5: ...the WAW pump afterloadingthecontainercausesthenormaloperationoftheCH pumptocomeback the pumps run as in PRIO mode Additionally during loading the container the presettemperatureoftheboileris raisedto6...

Страница 6: ...ents onthecontrolpanel fig 8 The operation state is presented on the graphic display 2 The screens inform about the operation of devices temperature of sensors they make it possible to change the para...

Страница 7: ...21 TempALARM_BOILER 61 TempALARM FLOOR o 9 2 Screen of boiler operation Thescreenfeaturescurrenttemperatureof theboilerandrotationof theblower Fig 82 Screen of boiler operation 18 WARNING WE INFORM T...

Страница 8: ...ler in case of the room thermostat operation TempBOILER TempTHERMOSTAT 17 PASSWORD 9999 HAS CONSIDERABLE MEANING IT CAUSES THE REACTIVATION OF THE PREVIOUS PASSWORD IF PRESENT WITHOUT IT BEING DISCLOS...

Страница 9: ...he cyclical run After that time the CH pump runs for 45secs Temperature hysteresis of turning on off the pumps The temperature difference between turning on and turning off the pumps It prevents often...

Страница 10: ...60min 45min The time of keeping up the low boiler temperature after which the transition to the stop state follows 3X blower DEFAULT boiler 30 ADJUSTABLE 31 10 100 100 32 1 10 o C 2 o C 38 2 10 o C 5...

Страница 11: ...ways when the controller is on Switching off the backlighting means it gets the value defined by the next parameter 15 Minimum LCD backlighting it s valid at the negative LCD The value 0 means a full...

Страница 12: ...t Parameter value change Upper and lower change limit THE PARAMETERS ADJUST THE CONTROLLER TO THE FEATURES OF THE BOILER AND THE CH SYSTEM THEIR CHANGE SHOULD BE CONSULTED WITH THE PRODUCER OF THE BOI...

Отзывы: