5
Za
łą
czony przeka
ź
nik STEROWANIE
Wskazanie górnego czujnika CWU
Wskazanie dolnego czujnika CWU
Wskazanie czujnika kominka
CO
*
KOM
?
CWU
80
o
73
o
68
o
12
1.
Control unit status diode: alarm (red), standby (orange), operation (green), manual MAN
(blinking green)
2.
Graphic display
3.
Button F1: switch-on/off power supply
4.
Increase button
5.
Decrease button
6.
Confirmation button
7.
Parameter selection button
8.
Button F2 (ESC - return to the main screen)
The control unit is equipped with the clock, which enables the automatic change of the control unit
operation at different times of day. 24 hrs are divided into 5 time zones (
) . Each zone
has a start time FROM and an end time TO. The same start and end time means the zone isn
’
t active,
which doesn
’
t change the settings of the control unit. The time zones can overlap each other in that
case binding are the settings for the active zone of higher number.
is not seen till the following alarm situation takes place:
1. Damage of the T1(BUFFER) sensor. The
text shows up.
2. Damage of the T2(KSL) sensor . The
text shows up.
3. Damage of the T3 sensor of the fireplace. The
text shows
up.
4. The exceeding of
The
text shows up.
5. The exceeding of
The
text shows up.
6. The exceeding of
The
text shows up.
Time zones
$1, $2, $3, e4, e5
BUF temp. sensor (T1) damaged
KSL temp. sensor (T2) damaged
Fplace temp. sensor (T3) damaged
too high temp. of the fireplace
too high temp. of the buffer
too high temp. of the collector
Alarm screen
“
ALARM
”
the limit temperature of the fireplace defined by the
parameter.
the limit temperature of the buffer
defined by the
parameter.
the limit temperature of the collector defined by the
parameter.
<21> ALARM Temp.
<24> BUF ALARM
Temp.
<26> ALARM Temp
KSL
3.1
!
3.2 Screens
THIS SOFTWARE VERSION DOES NOT INCLUDE THE TIME ZONES.
Pump P1
230V/50Hz
Pump P2
230V/50Hz
Pump P3
230V/50Hz
+
+
+
0
0
0
VCC
STER
GND
Temperature
sensors
AIR DAMPER
T1
PP
PE
T2
T3
MAINS
230V/50Hz
N N N N
L
1
2
3
L
L
L
N
PE
L
RED
BLUE
BLACK
Fig.3 Electrical wiring diagram
PP Air damper
T1 Temperature sensor of the BUF container (buffer container)
T2 Temperature sensor of the KSL collector (solar collector)
T3 Temperature sensor of the fireplace water jacket FIREPLACE
P1
Pump loading the BUF container from KSL
P2
Pump loading the BUF container from FIREPLACE
P3
CH circulating pump
CONTROL
FUSE
Alarm
text
4 Installing the control unit
!
!
!
!
THE
SHOULD NOT BE EXPOSED TO WATER AFFECTING. ITS
ENVIRONS OUGHT TO BE CLEAN.
THE PRODUCER DOESN'T TAKE ANY RESPONSIBILITY FOR DAMAGES CAUSED BY
WRONG USAGE OF THE
.
Connection diagram of the elements of the control unit is presented on fig. 3
THE CONTROL UNIT IS SUPPLIED BY 230V/50HZ .
ANY MOVES REGARDING INSTALLATION SHOULD BE MADE AT
THE DISCONNECTED MAINS.
THE CONTROL UNIT HAS TO BE CONNECTED TO THE MAINS WITH THE ZERO-PIN.
CONTROL UNIT
CONTROL UNIT