background image

4

13

2.6

3.

CONTROL

output

Service of the control unit

The control unit is equipped with the CONTROL relay whose contacts can be used e.g. to switch off
another heat source when the fireplace works. The

parameter defines the

function of the relay more precisely. (see PARAMETERS LEVEL 3)

CONTROL relay turned off

CONTROL relay turned on

There are elements on the control panel (fig. 2). In the turn-off state only the orange stanby state

LED (7) lights and the graphic display shows current temperature of the water jacket and current
time. The turn-on of the control unit follows by pressing the button ( ) ON/OFF

. In order to turn

it off press once more the button ( )and at the same time hold it down for about 1sec. In case of
supply voltage decline the control unit comes back to the state before the decline.
The operation state is presented on the graphic display ( ). The screens inform about the operation of
devices, temperature of sensors; they make it possible to change the parameters etc..The change of
screen is done by pressing the CHOOSE button ( ). If this is the screen that is able to change a
parameter, press the CONFIRM button ( ) , which causes blinking of the parameter field to be
changed. By pressing

+

( )or

-

( ) one can alter its value.

If there are more parameter fields on the screen (e.g. setting the clock) then one will go among them
by pressing the CHOOSE button ( ). By clicking the CONFIRM button ( ) one confirms the changes
- the parameter field stops blinking.

The changed parameter not confirmed for 10 secs is not accepted by the control unit and it recalls a

previous value of the parameter.

The button F2-ESC (8) is for cancelling a current operation and going over to the screen of the

fireplace.

<12> CONTROL Relay

3

3

2

7

6

4

5

7

6

!

!

Fig.2 Control panel view

Connection cable of the control may be replaced only

by producer or his authorized service locations

WARRANTY

WARNING !

ANY MODIFICATION OF THE CONTROL UNIT MADE BY A USER CAN
BE THE CAUSE OF SAFETY CONDITIONS DETERIORATION AND CAN

EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES
SUPPLIED

.

Date of sale

Seller's signature and stamp

Zak

ł

ad elektroniczny TATAREK Jerzy Tatarek

50-559 Wroclaw, 75 Swieradowska st

ph. (071) 367-21-67, 373-14-88, fax 373-14-58; tax index number 899-020-21-48;

Bank account : BZ WBK S.A. O/WROC

Ł

AW 6910901522-0000-0000-5201-9335

www.tatarek.com.pl.; E-mail: [email protected]

1.Warranty is valid [24] months from the date of sale.
2.Producer does not take responsibility for any mechanical damages made by user.
3.MAKING REPAIRS OR MODYFYING THE DEVICE BY USER IS
FORBIDDEN AND CAUSES WARRANTY CANCELATION
4.Warranty card is valid only with date of sale, seller's signature and stamp
5.Warranty and after-warranty repairs should be done only by producer, damaged
regulators should be sent to producer in order to make all repairs needed.
6.Warranty protection includes the EU
7.Warranty does not exclude, not restrict and not suspend buyer

s rights coming from

the incompatibility of the article with the agreement (Laws Journal No. 141 Pos. 1176)

WARNING!

1. Producer does not take the responsibility for damage
caused by atmospheric discharge
2. and overvoltage in the mains
3. Burnt fuses are not subject to warranty replacement

Register No.. GIOS: E 0002240WZ

Worn out electronic

and electric devices must be transfered to

the utilization collection place, where will

be accepted for free

ARGO-FILM
Recycling Plant No. 6
180 Krakowska st., 52-015 Wroclaw
ph.: 071 794 43 01,

0 515 122 142

“ON/OFF”

“CHOOSE”

“CONFIRM”

Содержание RT-08G-BUF-SOLAR

Страница 1: ...ion Housing protection class IP41 Fuse 6 3A 250V Number of outputs to control pumps 3 250W 230V 50Hz Number of nonvoltage outputs 1 Number of outputs to control the air damper drive 1 5V 500mA DC Numb...

Страница 2: ...tainer from the solar collector KSL P1 The pump of the collector P1 runs if the temperature of the collector T2 exceeds the temperatureofthebuffer T1 bytheparametervalue 64 DeltaKSL The next function...

Страница 3: ...p P1 2 4 2 5Summermode CH The collector pump P1 runs if the collector temperature T2 exceeds the buffer temperature T1 by thevalue Exceeding the maximum collector temperature parameter causes the KSLp...

Страница 4: ...ver to the screen of the fireplace 12 CONTROL Relay 3 3 2 7 6 4 5 7 6 Fig 2 Control panel view Connection cable of the control may be replaced only by producer or his authorized service locations WARR...

Страница 5: ...ce toohigh temp ofthebuffer toohigh temp ofthecollector Alarm screen ALARM the limittemperatureof thefireplace definedbythe parameter the limit temperature of the buffer defined by the parameter the l...

Страница 6: ...ION OF THE PREVIOUS PASSWORD IF PRESENT WITHOUT IT BEING EXPOSED PASSWORD OF PRODUCER S SERVICE IS UNIQUE AND IS NOT DEPENDENT ON THE USER S PASSWORD IT SHOUDN T BE EXPOSED TO THE USER INSTEAD OF THAT...

Страница 7: ...at which the alarm generates 75 95 o C 85 o C Fireplace temperature T3 at which the alarm turns on 5 25 o C 10 o C Decreasing fireplace temperature in relation to preset temperature at whose exceedin...

Страница 8: ...3 4 5 8 00 End of the 1st time zone 72 0 00 23 4 5 14 00 73 0 00 23 4 5 17 30 74 0 00 23 4 5 20 00 75 0 00 23 4 5 22 30 76 ECO4 from 0 00 23 4 5 23 00 Start of the 4th time zone economic 77 ECO4 to 0...

Отзывы: