8.0  FIELD INSPECTION

TFT’s G-Force is designed and manufactured to be damage resistant and require minimal maintenance. However, as the primary 
fi re fi ghting tool upon which your life depends, it should be treated accordingly.

Use with saltwater is permissible provided nozzle is thoroughly cleaned with fresh water after each use. The service life of the nozzle 
may be shortened due to the effects of corrosion and is not covered under warranty.

WARNING

Nozzle must be inspected  for proper operation and function according to the inspection 
checklist on last page before each use. Any nozzle that fails inspection is dangerous to use and 
must be repaired before using.

Performance tests shall be conducted on the G-Force nozzle after a repair, or anytime a problem is reported to verify operation in 
accordance with TFT test procedures. Consult factory for the procedure that corresponds to the model and serial number of the 
nozzle. Any equipment which fails the related test criteria should be removed from service immediately. Troubleshooting guides are 
available with each test procedure or equipment can be returned to the factory for service and testing.

CAUTION

Any alterations to the nozzle and its markings could diminish safety and constitutes a misuse 
of this product.

All Task Force Tip nozzles are factory lubricated with high quality silicone grease. This lubricant has excellent washout resistance 
and long term performance. If your department has unusually hard or sandy water, the moving parts may be affected. Foam agents 
and water additives contain soaps and chemicals that may break down the factory lubrication.

The moving parts of the nozzle should be checked on a regular basis for smooth and free operation, and signs of damage. IF THE 
NOZZLE IS OPERATING CORRECTLY, THEN NO ADDITIONAL LUBRICATION IS NEEDED.  Any nozzle that is not operating 
correctly should be immediately removed from service and the problem corrected.

9.0  REPAIR

Factory service is available with repair time seldom exceeding one day in our facility. Factory-serviced nozzles are repaired by 
experienced technicians to original specifi cations, fully wet tested, and promptly returned. Repair charges for non-warranty items 
are minimal. Any returns should include a note as to the nature of the problem and whom to reach in case of questions.

Task Force Tips assumes no liability for damage to equipment or injury to personnel that is a result of user service.

Repair kits and repair parts are stocked for immediate shipment. Contact the factory or visit the web site at www.tft.com for parts 
lists, exploded views, test procedures and trouble shooting guides.

10.0  COLOR CODED VALVE HANDLE AND PISTOL GRIP

The TFT G-FORCE with lever type valve handles are supplied with black valve handle covers and pistol grips. The handle covers 
and pistol grips are available from TFT in various colors for those departments wishing to color code the nozzle to the discharge 
controls. A colored handle cover set will be sent upon receipt of the warranty card by TFT. Your department’s name can also be 
engraved on the covers (see warranty card for more information).

Handle covers are replaceable by removing the four screws that hold the handle covers in place. Use a 3/32” allen wrench when 
replacing screws. Pistol grip is replaceable by following TFT instruction sheet LTT-108.

For standardization NFPA 1901 (A-4-9.3) recommends the following color code scheme:

Preconnect #1 or Bumper Jump Line

Preconnect or discharge #2 

Preconnect or discharge #3 

Preconnect or discharge #4 

Preconnect or discharge #5 

Preconnect or discharge #6 

Preconnect or discharge #7 

Foam Lines 

 

                            

Orange

Red

Yellow

White

Blue

Black

Green

Red w/ White border (Red/White)

Other Colors Available:

• Gray

• Pink

• Purple

• Tan

11.0  ANSWERS TO YOUR QUESTIONS

We appreciate the opportunity of serving you and making your job easier. If you have any problems or questions, our toll-free 
“Hydraulics Hotline”, 800-348-2686, is normally available to you 24 hours a day, 7 days a week.

Содержание G-Force

Страница 1: ...nt responders to know and understand the following 1 Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution a...

Страница 2: ...FIELD INSPECTION 9 0 REPAIR 10 0 COLOR CODED VALVE HANDLE AND PISTOL GRIP 11 0 ANSWERS TO YOUR QUESTIONS 12 0 DRAWINGS AND PART LISTS 13 0 INSPECTION CHECKLIST 14 0 WARRANTY 1 0 MEANING OF SAFETY SIG...

Страница 3: ...NING Water is a conductor of electricity Application of water on high voltage equipment can cause injury or death by electrocution The amount of current that may be carried back to the nozzle will dep...

Страница 4: ...our flow options are available All four use the selector ring for flush control The flow options are Fixed flow see section 4 1 Selectable flow see section 4 2 Automatic see section 4 3 Automatic with...

Страница 5: ...sh able with the selector ring 4 2 SELECTABLE FLOW A selectable G Force nozzle has several fixed discharge orifices and a flush setting A particular orifice is selected by rotating the selector ring F...

Страница 6: ...6 7 8 9 0 100 200 300 400 500 600 700 800 Flow LPM Pressure BAR Automatic G Force Flow Range 60 to 150 gpm at 100 psi 60 150 GPM 100 PSI AUTOMATIC 230 570 l min 700 kPa 7 bar AUTOMATIC FLUSH 0 20 40 6...

Страница 7: ...120 140 160 180 200 220 Flow LPM Pressure BAR Pressure psi Flow gpm FLUSH 60 150 GPM 100 PSI AUTO AUTOMATIC 250 570 l min 700 kPa 7 bar AUTO AUTOMATIC A B A B A B 95 150 GPM 100 PSI 30 95 360 570 l mi...

Страница 8: ...B A B 90 150 GPM 75 PSI 30 100 330 570 l min 500 kPa 5 bar 100 390 A B A B 0 100 200 300 400 500 600 700 800 0 1 2 3 4 5 6 7 8 9 0 20 40 60 80 100 120 140 0 20 40 60 80 100 120 140 160 180 200 220 Fl...

Страница 9: ...ge amounts or pieces of debris may be unflushable and can reduce the flow of the nozzle resulting in an ineffective flow In the event of a blockage it may be necessary to retreat to a safe area uncoup...

Страница 10: ...st reaching stream To properly trim the stream first open the pattern to narrow fog Then close the stream to parallel to give maximum reach Note Turning the shaper further forward will cause stream cr...

Страница 11: ...automatically become locked when the lock out lever moves to the top of the nozzle 5 2 4 STREAM PATTERN POSITION ADJUSTMENT Typically the G Force is factory set with the tactile indicator or lock out...

Страница 12: ...le for the purpose intended 6 1 FOAM ASPIRATING ATTACHMENTS To increase the expansion ratio Task Force Tips MX Foamjet model FJ MX G multi expansion attachment or LX Foamjet model FJ LX G low expansio...

Страница 13: ...correctly should be immediately removed from service and the problem corrected 9 0 REPAIR Factory service is available with repair time seldom exceeding one day in our facility Factory serviced nozzle...

Страница 14: ...02 14 12 0 DRAWINGS AND PART LISTS 1 6 7 8 9 4 5 10 3 20 21 22 23 24 25 26 27 10 28 29 30 31 1 2 4 5 11 12 11 13 14 15 16 19 18 17 7 47 52 53 54 55 56 57 17 62 47 48 49 50 51 45 41 42 43 44 46 58 58 3...

Страница 15: ...O 7 BAR 100 270 270 430 430 570 LPM G641L7LM AUTO 75 PSI 30 80 60 110 110 150 GPM G641L8L AUTO 5 BAR 100 300 240 430 420 570 LPM G641L8LM AUTO 100 PSI 60 150 GPM LOW 150 I O G641L9L AUTO 7 BAR 250 570...

Страница 16: ...r discovery of the defect TFT will examine the equipment If TFT determines that there is a defect attributable to it TFT will correct the problem within a reasonable time If the equipment is covered b...

Отзывы: