background image

©Copyright Task Force Tips, Inc. 2011-2013 

LIG-012 April 9, 2013 Rev02

5

2.3 MECHANICAL SPECIFICATIONS

Maximum inlet pressure with valve shut off

560 psi

40 bar

Operating temperature range of fl uid

33 to 120º F

1 to 50º C

Storage temperature range

-40 to 150º F

-40 to 65º C

Materials used

Aluminum 6000 series hard anodized MIL8625 class 
3 type 2, stainless steel 300 series, nylon 6-6, nitrile 
rubber, Torlon 4301 PAI

3.0  USE WITH SALTWATER

Use with saltwater is permissible provided nozzle is thoroughly cleaned with fresh water after each use. The service life of the 
nozzle may be shortened due to the effects of corrosion and is not covered under warranty.

4.0  FLOW CHARACTERISTICS
4.1  FIXED FLOW

A fi xed fl ow G-Force nozzle has one fi xed discharge orifi ce and a fl ush setting. A fi xed fl ow G-Force is fl ush able with the selector 
ring.

4.2  SELECTABLE FLOW

A selectable G-Force nozzle has several fi xed discharge orifi ces and a fl ush setting. A particular orifi ce is selected by rotating the 
selector ring. Figure 4.2A shows fl ow and pressure graphs for the G-Force Selectable nozzles.

0

20

40

60

80

100

120

140

0

20

40

60

80

100

120

140

160

180

200

220

Flow (gpm)

Pressure (psi)

0

1

2

3

4

5

6

7

8

9

0

100

200

300

400

500

600

700

800

Flow (LPM)

Pressure (BAR)

A

B

C

D

E

A

B

C

D

E

E

FLUSH

150 GPM @ 100 PSI

570 l/min @ 700 kPa (7 bar)

60

30

95

150

125

GPM @ 100 PSI

230

110

360

570

470

l/min @ 700 kPa (7 bar)

200

100

300

500

400

l/min @ 500 kPa (5 bar)

FIXED GALLONAGE

SELECTABLE GALLONAGE

0

20

40

60

80

100

120

140

0

20

40

60

80

100

120

140

160

180

200

220

Flow (gpm)

Pressure (psi)

0

1

2

3

4

5

6

7

8

9

0

100

200

300

400

500

600

700

800

Flow (LPM)

Pressure (BAR)

150 GPM @ 75 PSI

570 l/min @ 500 kPa (5 bar)

60

30

95

150

125

GPM @ 75 PSI

230

110

360

570

470

l/min @ 500 kPa (5 bar)

FIXED GALLONAGE

SELECTABLE GALLONAGE

A

B

C

D

E

E

FLUSH

A

B

C

D

E

Содержание G-Force

Страница 1: ...nt responders to know and understand the following 1 Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution a...

Страница 2: ...FIELD INSPECTION 9 0 REPAIR 10 0 COLOR CODED VALVE HANDLE AND PISTOL GRIP 11 0 ANSWERS TO YOUR QUESTIONS 12 0 DRAWINGS AND PART LISTS 13 0 INSPECTION CHECKLIST 14 0 WARRANTY 1 0 MEANING OF SAFETY SIG...

Страница 3: ...NING Water is a conductor of electricity Application of water on high voltage equipment can cause injury or death by electrocution The amount of current that may be carried back to the nozzle will dep...

Страница 4: ...our flow options are available All four use the selector ring for flush control The flow options are Fixed flow see section 4 1 Selectable flow see section 4 2 Automatic see section 4 3 Automatic with...

Страница 5: ...sh able with the selector ring 4 2 SELECTABLE FLOW A selectable G Force nozzle has several fixed discharge orifices and a flush setting A particular orifice is selected by rotating the selector ring F...

Страница 6: ...6 7 8 9 0 100 200 300 400 500 600 700 800 Flow LPM Pressure BAR Automatic G Force Flow Range 60 to 150 gpm at 100 psi 60 150 GPM 100 PSI AUTOMATIC 230 570 l min 700 kPa 7 bar AUTOMATIC FLUSH 0 20 40 6...

Страница 7: ...120 140 160 180 200 220 Flow LPM Pressure BAR Pressure psi Flow gpm FLUSH 60 150 GPM 100 PSI AUTO AUTOMATIC 250 570 l min 700 kPa 7 bar AUTO AUTOMATIC A B A B A B 95 150 GPM 100 PSI 30 95 360 570 l mi...

Страница 8: ...B A B 90 150 GPM 75 PSI 30 100 330 570 l min 500 kPa 5 bar 100 390 A B A B 0 100 200 300 400 500 600 700 800 0 1 2 3 4 5 6 7 8 9 0 20 40 60 80 100 120 140 0 20 40 60 80 100 120 140 160 180 200 220 Fl...

Страница 9: ...ge amounts or pieces of debris may be unflushable and can reduce the flow of the nozzle resulting in an ineffective flow In the event of a blockage it may be necessary to retreat to a safe area uncoup...

Страница 10: ...st reaching stream To properly trim the stream first open the pattern to narrow fog Then close the stream to parallel to give maximum reach Note Turning the shaper further forward will cause stream cr...

Страница 11: ...automatically become locked when the lock out lever moves to the top of the nozzle 5 2 4 STREAM PATTERN POSITION ADJUSTMENT Typically the G Force is factory set with the tactile indicator or lock out...

Страница 12: ...le for the purpose intended 6 1 FOAM ASPIRATING ATTACHMENTS To increase the expansion ratio Task Force Tips MX Foamjet model FJ MX G multi expansion attachment or LX Foamjet model FJ LX G low expansio...

Страница 13: ...correctly should be immediately removed from service and the problem corrected 9 0 REPAIR Factory service is available with repair time seldom exceeding one day in our facility Factory serviced nozzle...

Страница 14: ...02 14 12 0 DRAWINGS AND PART LISTS 1 6 7 8 9 4 5 10 3 20 21 22 23 24 25 26 27 10 28 29 30 31 1 2 4 5 11 12 11 13 14 15 16 19 18 17 7 47 52 53 54 55 56 57 17 62 47 48 49 50 51 45 41 42 43 44 46 58 58 3...

Страница 15: ...O 7 BAR 100 270 270 430 430 570 LPM G641L7LM AUTO 75 PSI 30 80 60 110 110 150 GPM G641L8L AUTO 5 BAR 100 300 240 430 420 570 LPM G641L8LM AUTO 100 PSI 60 150 GPM LOW 150 I O G641L9L AUTO 7 BAR 250 570...

Страница 16: ...r discovery of the defect TFT will examine the equipment If TFT determines that there is a defect attributable to it TFT will correct the problem within a reasonable time If the equipment is covered b...

Отзывы: