17 – Specifications—Messages and troubleshooting
136
TASCAM DM-24 Reference Manual
✔
Signal Info: Word
New clock source is out of range,
Master clock is unchanged.
Press ENTER to continue.
An attempt has been made to select a new clock source, which is out of range
(“CLOCK settings” on page 24).
✖
SLOT1 Card is Unknown
Check Card Type
Press ENTER key to continue.
The DM-24 cannot recognize the card fitted in the optional slot. Check the card
and its installation in the DM-24. Contact your TASCAM dealer for assistance if
necessary.
●
Snapshot000 is Read Only!
An attempt is being made to overwrite a read-only snapshot library entry
(“Library functions” on page 99).
●
Snapshotxxx Recalled.
Snapshot xxx has been successfully recalled from the library (“Library func-
tions” on page 99).
✖
Source Fs unlocked.
Press ENTER to continue.
The sampling frequency of the clock source is no longer valid. Reconnect if
necessary, and recheck the source (“CLOCK settings” on page 24).
✔
ST LINK ON(CH EVEN—>ODD)
Press ENTER to confirm,
or a cursor key to cancel.
Shown when the SEL keys are used to link two channels (“Linking and unlinking
modules” on page 60)
.
✔
ST LINK ON(CH ODD—>EVEN)
Press ENTER to confirm,
or a cursor key to cancel.
Shown when the SEL keys are used to link two channels (“Linking and unlinking
modules” on page 60).
✔
ST LINK ON(CH xx—>yy)
and
Re-assign fader (cut) grouping?
Press ENTER to confirm,
or a cursor key to cancel.
Shown when SEL keys are used to link two channels and the stereo link will
cause a current group assignment to change (“Linking and unlinking modules”
on page 60).
✔
ST LINK OFF(CH ODD—>EVEN)
Press ENTER to confirm,
or a cursor key to cancel.
Shown when SEL keys are used to break a channel link.(“Linking and unlinking
modules” on page 60).
●
STEREO L-R is already inserted.
An attempt has been made to assign a second insert loop to the stereo buss
when an insert loop has already been assigned to it (“Master settings” on
page 40.
✔
STEREO to Aux1-2 is assigned.
Press ENTER to continue.
In the master buss assignment, this warning appears if an attempt is made to
override an existing assignment (“AUX 1-2” on page 40).
●
Store to Automation Bank01.
Shown when storing automation data.
●
Stored to COMP Libraryxxx
from CHy.
The compressor settings from channel y are now stored in EQ library entry xxx
(“Library functions” on page 99).
●
Stored to Effect Libraryxxx.
The effector settings are now stored in library entry xxx (“Library functions” on
page 99).
●
Stored to EQ Libraryxxx
from CHy.
The EQ settings from channel y are now stored in EQ library entry xxx (“Library
functions” on page 99).
●
Stored to GATE/EXPAND Libraryxxx
from CHy.
The gate/expander settings from channel y are now stored in EQ library entry
xxx (“Library functions” on page 99).
●
Stored to Snapshotxxx.
The snapshot settings have been successfully stored to snapshot library entry
xxx (“Library functions” on page 99).
✔
SYSTEM update Ready _
Press a cursor key to cancel.
The system software is ready to be upgraded. Cancel the operation by pressing
any of the cursor keys.
●
There is no current data.
Shown as a warning that there is no current data to be manipulated (automa-
tion)
Action
Message
Explanation