XLR pin
RJ45 pin
Function
1
7, 8
signal common
2
2
data -
3
1
data +
4, 5
no contact
not used
Connect the lights together in a serial chain, output to input.
Connect no more than 32 lights and keep the total cable run
to 300 m (1000 ft.) or less. If the application exceeds these
limits, DMX splitter/amplifiers may be used after the power
supply to increase the cable run and/or number of lights.
Line terminator
Terminate the end of the data line to prevent reflections that
can distort the signal. This is usually accomplished by
inserting a suitable 120 ohm termination plug into the DMX
output of the last fixture in the line.
AC power supply cable plug
Warning: Risk of electric shock! Plug
installation shall be performed by a q
electrician.
ualified
A grounding-type (earthed) power plug that fits the local
power outlet must installed on the AC cable for the power
supply. Alternatively, you can acquire an IEC power cable
with a suitable grounding-type plug from most consumer
electronics stores.
When installing the plug connect pins as follows:
•
yellow and green wire to ground (earth)
•
blue wire to neutral
•
brown wire to live