Recommended wire gauge & fuse
Caution: Using wire gauges below the recommendation will result in power loss and
overheating of wiring.
Positive / negative power supply cable _________________
___________ 2 x 2/0 AWG
Check polarity and never reverse power supply cables due to the risk of damage to the
amplifier.
Calculated considering a maximum length of 4m. Distance greater than this, you will
need to increase the cable gauges.
Remote cable ___________________
________________________________ 18 AWG
Protection fuse or circuit breaker
______________________________________ 390A
Output cables with gauge_______________________________
___________ 7 AWG
Installation
CAUTION: All connections to power supply, input and output connectors must be
carried out only with amplifier off.
ENGLISH
11
70mm² (2/0 A
WG)
70mm² (2/0 A
WG)
12V
GND
GND
12V
Illustrative images
10mm² (7 AWG)
10mm² (7 AWG)
SPEAKER
IN
OUT
MONITOR
0.2
GAIN
4
BASS BOOST
BOOST
+10
0
dB
FREQ.
55
35
Hz
Hz
Hz
LOW PASS
90
10
CROSSOVER
HIGH PASS
10K
90
V
Other Amplifier
Head Unit
Remote Cable 18 A
WG
At least 390Ah
Note: Required battery bank capacity:
Circuit Breaker
PROT
IN
OUT
RCA Cable
Taramps