2 - POSITIVE POWER SUPPLY:
Use 2/0 AWG cables direct from the positive battery terminal, with fuse or
circuit breaker (390A), as close to it as possible.
In order for your amplifier to have the best performance, it is necessary to use all the power inputs. See
example on the next page. We recommend that all cables have tinned ends for better electrical contact.
In case of power bus bar using, avoid tightening with extenders on the allen wrench, as excessive torque
may break the the terminal.
1 - Fans:
This amplifier has two internal ventilation fans, which cannot be obstructed. For a perfect
operation, the amplifier must be installed in a dry and airy place. We recommend not embedding it, in
order to ensure adequate ventilation.
3 - NEGATIVE POWER SUPPLY:
Use 2/0 AWG cables as short as possible, connected to the negative
battery pole.
Power supply connector
10
ENGLISH
Indicates that the amplifier is turned on.
Blinking yellow LED according to music:
Indicates that the amplifier is operating at the
threshold of distortion. If the red LED also blinks, it indicates excessive distortion.
Short-circuit or impedance lower than that supported at output.
Flashing yellow LED:
Excessive temperature (May be caused by obstruction of the
internal fans, improper installation or poorly ventilated location).
Red LED steady on:
We recommend don’t turn off the amplifier, so that the cooling time will be shorter,
through the ventilation of fans.
Supply voltage less than 9.5V.
RED LED flashes 2x:
Power supply voltage greater than 17V.
Blue LED steady on:
When the amplifier reaches the temperature of approximately 80°C (176°F), the thermal
protection starts working, the audio is interrupted and the yellow LED will start flashing.
The fans will be functioning, in order to cool down the components quickly. Only when
the amplifier reaches a safe temperature level, the audio is released and the amplifier
gets back to its normal functioning.
RED LED flashes 3x:
LEDS indicators & protection systems