11
CIRCUIT BREAKE
12V
GND
6mm² (9 AWG)
6mm² (9 AWG)
21mm² (4 A
WG)
21mm² (4 A
WG)
RCA Cable
Taramps
Remote Cable 18AWG
*Illustrative images
Head Unit
Remote cable ___________________
______________________________________ 18 AWG
Output cables wire gauge_______________________________
_________________9 AWG
Protection fuse or circuit breaker
____________________________________________150A
Calculated considering a maximum length of 4m. Distance greater than this, you will need to
increase the cable gauges.
Positive / negative power supply cable ___________________
___________________4 AWG
Installation
Recommended wire gauge & fuse
11
CAUTION: All connections to power supply, input and output connectors must
be carried out only with amplifier off.
CAUTION
Using wire gauges below the recommendation will result in power loss and
overheating of wiring.
Check polarity and never reverse power supply cables due to the risk of damage to the amplifier.
It is compulsory to install a protection fuses or circuit breakers as close as possible from batteries.
CAUTION
This equipment is not suitable
for use in places where children may be present.
CUIDADO
Note:
In case of compression driver and tweeters you
must install a passive filter in the positive terminal of the
same ones (Consult transducer’s manufacturer manual).
At least 150Ah
Examples of connections in the power supply input.
Note: Required battery bank capacity:
CUIDADO
The entire aluminum
surface of the amplifier
serves as a heat sink. The usually working
temperature is 65°C. So, avoid contact with
this surface when the amplifier is in use.