CIRCUIT BR
AKE
CIRCUIT BR
AKE
12V
GND
10mm² (7 AWG)
10mm² (7 AWG)
2 x 70mm² (2/0 A
WG)
2 x 70mm² (2/0 A
WG)
*Illustrative images
Remote Cable 18A
WG
RCA Cable
Taramps
Head Unit
PROT
AMPLIFIER - 12000WATTS
PROT
Note:
In case of compression drivers and tweeters you must install a passive filter in the positive
terminal of the same ones (Consult transducer’s manufacturer manual).
11
Output cables wire gauge_______________________________
_________________7 AWG
Remote cable ___________________
______________________________________ 18 AWG
Protection fuse or circuit breaker
____________________________________________600A
Calculated considering a maximum length of 4m. Distance greater than this, you will need to
increase the cable gauges.
Positive / negative power supply cable ___________________
_______________2 x 2/0 AWG
Installation
Recommended wire gauge & fuse
CAUTION: All connections to power supply, input and output connectors must
be carried out only with amplifier off.
CAUTION
Using wire gauges below the recommendation will result in power loss and
overheating of wiring.
It is compulsory to install a protection fuses or circuit breakers as close as possible from batteries.
Check polarity and never reverse power supply cables due to the risk of damage to the amplifier.
CAUTION
This equipment is not suitable
for use in places where children may be present.
CAUTION
Examples of connections in the power supply input.
Note: Required battery bank capacity: At least 600Ah
CUIDADO
The entire aluminum
surface of the amplifier
serves as a heat sink. The usually working
temperature is 65°C. So, avoid contact with
this surface when the amplifier is in use.