![Taramps MD12000.1 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/taramps-0/md12000-1/md12000-1_instruction-manual_818836010.webp)
Functions, inputs & outputs
1 - INPUT (R and L):
Inputs of signals to be amplified. Connect these signals to RCA outputs of Head Unit ,
using good quality shielded cables to avoid noise influence.
5 - MONITOR:
Connection to an accessory, which function is to monitor the amplifier and it is where
all information from the indicator LEDs, such as distortion (CLIP/TEMP) and protection actuation
(PROT), will be displayed simultaneously.
(Accessory not included).
To combine speakers, the resulting impedance must be taken into consideration.
BOOST
: Boost for bass, with variable gain up 0 to +10dB.
6 - SPEAKER:
Output (positive and negative) to transducers connection (speakers). Follow the polarity
described and the minimum impedance recommended.
3 - CROSSOVER
2 - LEVEL:
It sets the amplifier input sensitivity, which allows an optimal adjustment to the output signals
levels of nearly all models of Head Unit found in the market.
HIGH PASS:
Variable adjustment from 10Hz to 90Hz, which determines the beginning of the amplifier
operating frequency.
LOW PASS:
Variable adjustment from 90Hz to 5KHz, which determines the end of the amplifier
operating frequency.
4 - BASS BOOST
FREQ.:
Set the Bass Boost center frequency, from 35Hz up to 55Hz.
See the examples below:
7 - REMOTE TERMINAL:
The remote Head Unit output must be connected by a 0,75mm² (18 AWG) cable.
4 OHMS
4 OHMS
4 OHMS
4 OHMS
Amplifier 1 OHM
Resulting
impedance:
1 OHM
2 OHMS
2 OHMS
2 OHMS
2 OHMS
Resulting
impedance:
0.5 OHM
Amplifier 0.5 OHM
1
2
3
4
5
7
6
09
Due to the presence of voltage at the output terminals when the product is turned on,
avoid contact with them. Risk of electric shock.