1.
INSTALLATION
Steinle Filter Press Pump Series
13
1.9.
Installation example
1.10.
Recommended installations
The FP/FH pump is flexible in the way you are able to install it.
1.10.1.
Flooded
The piping system is designed with a positive suction head. This is the best way of installation
where it is necessary to completely evacuate all liquid from the container, or where viscous
(thick) products are transferred.
1.10.2.
Self-priming
The FP/FH pump is designed to pull a vacuum. It is able to evacuate an empty suction pipe
without any damage to the pump. The suction lift is up to 2 meters (6.6 ft.) from an empty
suction pipe and up to 5 meters (16.4 ft.) from a wetted pipe. The suction capability depends
on the pump size (see chapter
5. “Data”
).
NOTE!
Even if all above safety instructions are met and complied with, there still exists a minor danger
in the event of a leakage or mechanical damage of the pump. In such case the pumped product
can emerge on sealing areas and connections.
1.11.
Electric Connection
The pump needs a power supply for the operation of the solenoid valve. Please keep care,
that the installation is done properly according to the national standards. Tight the cable
fittings to avoid the ingress of water. All internal cable wiring is done.