2. OPERATION
Steinle Filter Press Pump Series
19
If the ambient air is humid, icing can occur outside of the muffler. In such case it is
recommended to use a longer exhaust of the compressed air (ca. 500 mm / 19,7’’).
Operate the pump as slow as possible.
2.3.
Pump stopping
The pump can be stopped in three ways:
1)
Close the discharge valve. The pressure from the system will stop the pump
automatically. This will not do any damage to the pump. The pump restarts easy when
the valve is opened again.
2)
By cutting off the air supply.
3)
Switch off control panel
2.4.
Residual risks
Even with proper application and observance of all points listed in this operating manual,
there is still an estimable and unexpected residual risk when using the pumps. It may leak,
fail due to wear, application-related causes or system-related circumstances.
2.5.
Disposal after expiration of the expected lifetime
The metallic components like aluminium, stainless steel and carbon steel can be recycled.
Plastic parts are not recyclable and must be disposed of as residual waste. The pump must
be disposed of properly, according to local regulations. It should be noted that potentially
dangerous fluid residues may remain in the pump and can create a hazard to the operator
or the environment, therefore the pump has to thoroughly cleaned before disposal.
The hydraulic liquid is biodegradable; however, it must be recycled according to national
regulations.
2.6.
Waste of electrical and electronic equipment (WEEE) directive
Users of electrical and electronic equipment (EEE) with the WEEE
marking per Annex IV of the WEEE Directive must not dispose of end
of life EEE as unsorted municipal waste, but use the collection
framework available to them for the return, recycle, recovery of WEEE
and minimize any potential effects of EEE on the environment and
human health due to the presence of hazardous substances. The WEEE
marking applies only to countries within the European Union (EU) and Norway. Appliances
are labelled in accordance with European Directive 2002/96/EC. Contact your local waste
recovery agency for a designated collection facility in your area.
2.7.
Actions in emergency
In case of a leakage of an unknown fluid, respiratory protection should be worn and
contact with the fluid avoided. During firefighting, keep in mind that hydraulic part of
pump is filled with oil and control unit is connected to electricity. In addition, the currently