TapFlo CTV 40-13.5 Скачать руководство пользователя страница 21

  

Instruction manual CTV vertical pumps 

21

6  Repair or replacement under the terms of this warranty shall not give a right to an extension 

to, or a new commencement of, the period of warranty.  Repair or replacement under the 

terms of this warranty may be fulfilled with functionally equivalent reconditioned units. Tapflo 

qualified personnel shall be solely entitled to carry out repair or replacement of faulty parts 

after careful examination of the pump.  Replaced faulty parts or components will become the 

property of Tapflo

7  The products are built in accordance with standard CE normative and are tested (where app

-

licable) by Tapflo. Approval and tests by other control authority are for the customers account.  

The products shall not be considered defective in materials, design or workmanship if they 

need to be adapted, changed or adjusted to conform to national or local technical or safety 

standards in force in any country other than that for which the unit was originally designed and 

manufactured.  This warranty shall not reimburse such adaptations, changes or adjustments, 

or attempt to do so, whether properly performed or not, nor any damage resulting from them, 

nor any adaptation, change or adjustments to upgrade the products from their normal purpose 

as described in the products operative manual without the prior written consent of Tapflo

8  Installation, including electric and other connections to utility mains according to Tapflo drawings, 

is for the cost and responsibility of the customer, unless otherwise agreed in writing.

9  Tapflo  will not be liable on any claim, whether in contact, tort, or otherwise, for any indirect, 

special, incidental, or consequential damages, caused to the customer or to third parties, in

-

cluding loss of profits, arising by any possible infringement of par. 3 above or by the customer 

or third parties being in the impossibility of using the products.

Steady the above,Tapflo liability to the customer or third parties from any claim, whether in cont

-

ract, tort, or otherwise, shall be limited to the total amount paid by the customer for the product 

that caused the damages.

 

6.  WARRANTY & REPAIR

Содержание CTV 40-13.5

Страница 1: ...efully before you install and operate the pump Edition 1 2008 hi arbetsfiler instruktioner tapflo pumpar ctv vertical centrifugal pumps ctv pumps instruction manual english rev 1 2008 indd CTV series...

Страница 2: ...AINTENANCE 11 3 1 Maintenance schedule 11 3 2 Trouble shooting 11 3 3 Assembly and disassembly 12 3 3 1 Assembly drawings 12 3 3 2 Dismantling PP PVDF pumps 13 3 3 3 Dismantling stainless steel pumps...

Страница 3: ...umps Models CTV Is in conformity with the essential health and safety requirements and technical con struction file requirements of the EC Machinery directive 89 393 EEC with amendments 91 368 EEC 93...

Страница 4: ...Inform also other users of all safety instructions In addition to the instructions in this instruction manual the general safety and accident prevention regulations must be observed This symbol signal...

Страница 5: ...c motor Inlet 0 5 General limits CTV pumps are made from polypropylene PP polyvinylidene fluoride PVDF or stainless steel AISI 316L Temperature General limits based on water With other chemicals the l...

Страница 6: ...or approach rotating parts in movement Noise level CTV pumps including the motor in normal operating conditions produce a sound level below 80 dB A The major sources of noise are liquid turbulence in...

Страница 7: ...t can include a number of components such as valves fittings filters expansion joints instruments etc The way the piping is arranged and the positioning of the components has a great influence on oper...

Страница 8: ...k sump installations Installations with suction extension 8 Vertical suction extension allowed Size of pipe shall correspond with connection size No complex piping system on suction side In particular...

Страница 9: ...he pumped liquid can be a critical element provide a thermometer 1 7 Motor Connection An expert electrician must always carry out the electrical connection Compare the power supply with the data plate...

Страница 10: ...o or three minutes with discharge closed A longer operation in these conditions can damage the pump If the pressure shown on the pressure gauge on the discharge piping does not increase turn off the p...

Страница 11: ...charge clogged Impeller damaged Wrong direction of rotation Check piping system Clean the pump internally Change impeller See chapter 1 7 for change of direction Insufficient head Air in the casing or...

Страница 12: ...disconnected The pump motor unit must be placed in a position where it cannot be started unintentionally Before servicing in any way the parts in contact with the pumped liquid make sure that the pum...

Страница 13: ...ling stainless steel pumps After removal of eventual suction extension or strainer place the pump horizontally on a bench Unscrew the casing mounting screws with washers 141 and 142 and lift carefully...

Страница 14: ...1 PP or PVDF 132 Lock ring 1 PP or PVDF 15 Shaft bushing 1 Ceramic 151 Shaft bushing o ring 1 NBR 161 Lip seal 1 NBR or FKM 162 Shaft sleeve 1 PP or PVDF 17 Elbow 1 PP or PVDF 18 Casing o ring 1 EPDM...

Страница 15: ...rew 4 Stainless steel 142 Casing mounting washer 4 Stainless steel 143 Casing mounting nut 4 Stainless steel 15 Shaft bushing 1 Ceramic 161 Lip seal 1 NBR or FKM 162 Shaft sleeve 1 AISI 316L 17 Elbow...

Страница 16: ...8 5 25 9 8 15 1 5 kW CTV 25 11 5 32 10 40 12 5 22 2 2 kW CTV 32 12 5 40 13 5 Standard execution Changes reserved without notice PP PVDF pumps Pos Description Qty 161 Lip seal 1 193 Impeller o ring 1 1...

Страница 17: ...DATA 5 1 Performance curves The performance curves are based on water at 20 C Speed 2900 rpm Contact us for detailed curves 5 1 1 Performance curves PP PVDF pumps Changes reserved without notice 5 1...

Страница 18: ...Max head m 10 14 16 19 10 17 23 Motor power kW 0 55 0 75 1 1 1 5 1 1 1 5 2 2 Outlet dimension male BSP 1 1 1 1 1 1 4 1 1 4 1 1 4 Motor data 3 phase 2 pole 2900 rpm 380 420 VAC 50 Hz IP 55 Max tempera...

Страница 19: ...r power kW 0 55 0 75 1 1 1 5 2 2 2 2 Outlet dimension male BSP 3 4 1 1 1 1 2 1 1 2 1 1 2 Motor data 3 phase 2 pole 2900 rpm 380 420 VAC 50 Hz IP 55 Max temperature 100 C Materials Pumpcasing and impel...

Страница 20: ...ng the products including all warranties of fitness for a particular purpose 3 This warranty shall not be applicable in circumstances other than defects in material design and workmanship In particula...

Страница 21: ...was originally designed and manufactured This warranty shall not reimburse such adaptations changes or adjustments or attempt to do so whether properly performed or not nor any damage resulting from t...

Страница 22: ...was installed date Pump type Serial No see name plate Description of the fault The installation Liquid Temperature C Viscosity cPs Spec grav kg m3 pH value Contents of particles of max size mm Flow l...

Страница 23: ...Instruction manual CTV vertical pumps 23 NOTES...

Страница 24: ...DISTRIBUTOR Tapflo AB Filaregatan 4 S 442 34 Kung lv Sweden Tel 46 303 63390 Fax 46 303 19916 E mail sales tapflo com www tapflo com...

Отзывы: