TapFlo CTV 40-13.5 Скачать руководство пользователя страница 20

Instruction manual CTV vertical pumps 

20

 

6. WARRANTY & REPAIR

6.1 

Returning parts

When returning parts to Tapflo AB please follow this procedure:

-   Consult Tapflo AB for shipping instructions.

-   Cleanse or neutralize and rinse the part/pump. Make sure the part/pump is completely empty 

from liquid.

-   Pack the return articles carefully to prevent any damage under transport.

Goods will not be accepted unless the above procedure has been complied with.

6.2 

Warranty

Tapflo warrants products under conditions as below for a period of not more than 12 months from 

installation and not more than 24 months from date of manufacture.

1.  The following terms and condition apply to the sale of machinery, components and related 

services and products, of Tapflo  (hereinafter “the products”)

2.  Tapflo (the manufacturer) warrants that:

a.)  its products as being free of defects in material, design and workmanship at the time of original 

purchase;

b.)  its products will function in accordance with Tapflo operative manuals; Tapflo does not guaran

-

tee that the product will meet the precise needs of the Customer, except for those purposes 

set out  in any invitation to render documents or other documents specifically made available 

to Tapflo before entering into this agreement;

c.)  high quality materials are used in the construction of the pumps and that machining and as

-

sembly are carried out to the highest standards.

Except as expressly stated above, Tapflo makes no warranties, express or implied, concerning 

the products, including all warranties of fitness for a particular purpose.

3.  This warranty shall not be applicable in circumstances other than defects in material, design, 

and workmanship. In particular warranty shall not cover the following:

a.)  Periodic checks, maintenance, repair and replacement of parts due to normal wear and tear 

(seals, O-rings, rubber items, bushings, etc..);

b.)  Damage to the product resulting from:

b.1.) Tampering with, abuse or misuse, including but not limited to failure to use the product for its 

normal purposes as stated at the time of purchase or in accordance withTapflo instructions 

for use and maintenance of the product, or the installation or improper ventilation or use of 

the product in a manner inconsistent with the technical or safety standard in force;

b.2.) Repairs performed by non skilled personell or use of non original Tapflo parts

 

b.3.) Accidents or any cause beyond the control of Tapflo, including but not limited to lightning, 

water, fire, earthquake, and public disturbances, etc.;

4  The warrantee shall cover the replacement or repairing of any parts, which is documentedly 

faulty due to construction or assembling, with new or repaired parts free of charges delive

-

red by Tapflo. Parts subjected to normal tear and wear shall not be covered by the warranty.  

Tapflo shall decide as to whether the defective or faulty part shall be replaced or repaired.

5  The warrantee of the products shall be valid for a period in accordance to the current law 

from the date of delivery, under the condition that notice of the alleged defect to the products 

or parts thereof be given to Tapflo in written within the mandatory term of 8 days  from the 

discovery.

Содержание CTV 40-13.5

Страница 1: ...efully before you install and operate the pump Edition 1 2008 hi arbetsfiler instruktioner tapflo pumpar ctv vertical centrifugal pumps ctv pumps instruction manual english rev 1 2008 indd CTV series...

Страница 2: ...AINTENANCE 11 3 1 Maintenance schedule 11 3 2 Trouble shooting 11 3 3 Assembly and disassembly 12 3 3 1 Assembly drawings 12 3 3 2 Dismantling PP PVDF pumps 13 3 3 3 Dismantling stainless steel pumps...

Страница 3: ...umps Models CTV Is in conformity with the essential health and safety requirements and technical con struction file requirements of the EC Machinery directive 89 393 EEC with amendments 91 368 EEC 93...

Страница 4: ...Inform also other users of all safety instructions In addition to the instructions in this instruction manual the general safety and accident prevention regulations must be observed This symbol signal...

Страница 5: ...c motor Inlet 0 5 General limits CTV pumps are made from polypropylene PP polyvinylidene fluoride PVDF or stainless steel AISI 316L Temperature General limits based on water With other chemicals the l...

Страница 6: ...or approach rotating parts in movement Noise level CTV pumps including the motor in normal operating conditions produce a sound level below 80 dB A The major sources of noise are liquid turbulence in...

Страница 7: ...t can include a number of components such as valves fittings filters expansion joints instruments etc The way the piping is arranged and the positioning of the components has a great influence on oper...

Страница 8: ...k sump installations Installations with suction extension 8 Vertical suction extension allowed Size of pipe shall correspond with connection size No complex piping system on suction side In particular...

Страница 9: ...he pumped liquid can be a critical element provide a thermometer 1 7 Motor Connection An expert electrician must always carry out the electrical connection Compare the power supply with the data plate...

Страница 10: ...o or three minutes with discharge closed A longer operation in these conditions can damage the pump If the pressure shown on the pressure gauge on the discharge piping does not increase turn off the p...

Страница 11: ...charge clogged Impeller damaged Wrong direction of rotation Check piping system Clean the pump internally Change impeller See chapter 1 7 for change of direction Insufficient head Air in the casing or...

Страница 12: ...disconnected The pump motor unit must be placed in a position where it cannot be started unintentionally Before servicing in any way the parts in contact with the pumped liquid make sure that the pum...

Страница 13: ...ling stainless steel pumps After removal of eventual suction extension or strainer place the pump horizontally on a bench Unscrew the casing mounting screws with washers 141 and 142 and lift carefully...

Страница 14: ...1 PP or PVDF 132 Lock ring 1 PP or PVDF 15 Shaft bushing 1 Ceramic 151 Shaft bushing o ring 1 NBR 161 Lip seal 1 NBR or FKM 162 Shaft sleeve 1 PP or PVDF 17 Elbow 1 PP or PVDF 18 Casing o ring 1 EPDM...

Страница 15: ...rew 4 Stainless steel 142 Casing mounting washer 4 Stainless steel 143 Casing mounting nut 4 Stainless steel 15 Shaft bushing 1 Ceramic 161 Lip seal 1 NBR or FKM 162 Shaft sleeve 1 AISI 316L 17 Elbow...

Страница 16: ...8 5 25 9 8 15 1 5 kW CTV 25 11 5 32 10 40 12 5 22 2 2 kW CTV 32 12 5 40 13 5 Standard execution Changes reserved without notice PP PVDF pumps Pos Description Qty 161 Lip seal 1 193 Impeller o ring 1 1...

Страница 17: ...DATA 5 1 Performance curves The performance curves are based on water at 20 C Speed 2900 rpm Contact us for detailed curves 5 1 1 Performance curves PP PVDF pumps Changes reserved without notice 5 1...

Страница 18: ...Max head m 10 14 16 19 10 17 23 Motor power kW 0 55 0 75 1 1 1 5 1 1 1 5 2 2 Outlet dimension male BSP 1 1 1 1 1 1 4 1 1 4 1 1 4 Motor data 3 phase 2 pole 2900 rpm 380 420 VAC 50 Hz IP 55 Max tempera...

Страница 19: ...r power kW 0 55 0 75 1 1 1 5 2 2 2 2 Outlet dimension male BSP 3 4 1 1 1 1 2 1 1 2 1 1 2 Motor data 3 phase 2 pole 2900 rpm 380 420 VAC 50 Hz IP 55 Max temperature 100 C Materials Pumpcasing and impel...

Страница 20: ...ng the products including all warranties of fitness for a particular purpose 3 This warranty shall not be applicable in circumstances other than defects in material design and workmanship In particula...

Страница 21: ...was originally designed and manufactured This warranty shall not reimburse such adaptations changes or adjustments or attempt to do so whether properly performed or not nor any damage resulting from t...

Страница 22: ...was installed date Pump type Serial No see name plate Description of the fault The installation Liquid Temperature C Viscosity cPs Spec grav kg m3 pH value Contents of particles of max size mm Flow l...

Страница 23: ...Instruction manual CTV vertical pumps 23 NOTES...

Страница 24: ...DISTRIBUTOR Tapflo AB Filaregatan 4 S 442 34 Kung lv Sweden Tel 46 303 63390 Fax 46 303 19916 E mail sales tapflo com www tapflo com...

Отзывы: