5
We reserve the right to make changes in technical information.
5.
CONSTRUCTION
Information on the physical structures and dimensions of the storage water heater and hot
water storage tank covered by this manual is below.
5.1.
TSB, TDB series storage water heater
• C
apacity:
100 – 3000 liters
•
Designated use:
Hot water not exceeding 90°C
•
Operation pressure:
10 bar
•
Mounting position:
Vertical
•
Coating of water-contact surfaces:
Enamel
•
Insulation:
100-500 liters 50 mm thick hard polyurethane, 800-3000 liters 80 mm thick open cell
sheath
•
Standard accesories:
Protective anode, thermometer
The heating capacity of the TSB and TCB series storage water heaters depends on the flow rate and
temperature of the hot water circulated in the coil. The domestic hot water supply values given in
the catalog are valid if the heating water inlet temperature, and the flow rate corresponding to the
capacity specified herein, are realized. For this reason, check whether the capacity of the heat
sources in the heating system (boiler, solar panel, electric heater etc.) and the characteristics of
the heating water circulating pump provide these values!
Single Coil (TSB)
Note:
Upon request, products can also be delivered in non-standard capacities; electrical heater and panel can be
added.
Temperature
sensor connection
Electric coil
connection
Temperature
sensor connection
Manhole
access
soft polyurethane
•
Protective
sleeve:
100-500 liters electrostatic powder coated steel sheet, 800-3000 liters vinyl
Hot water exit
Heating inlet
Hot water return
Heating exit
Cold water intake
Thermometer
Protective anode
Drain